← Back
Predominantly retail with other uses
8905 GLENWOOD ROAD
BROOKLYN · BIN 3224104
💬 Discuss this project
1930Year Built
2Stories
K4Building Class
R4-1Zoning
2,397 sfGross Floor Area
2Units
Predominantly retail with other uses · Owner of record: BROOKS VISION LLC · 2,000 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Floor 24p · 1 filing · 20 docs
Floor 13p · 1 filing · 20 docs
Cellar3p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/05/2022$550K—Private party → BROOKS VISION LLC$229/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MELDAN GROUP LLC810/13/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
T C ENTERPRISES1203/21/2026
ORION PLUMBING HEATING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A-MAC OF NEW YORK CONSTRUGeneral Contractor404/09/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MELDAN GROUP LLC8100810/13/2025
Building Lifecycle
All (44)Filed (8)Permit Issued (3)Inspection (11)Objection (4)Special Inspection (18)
04/13/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/13/2025
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P6
10/02/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Reid
10/02/2025
Special inspection requirement — Insulation placement and R values
Jeffrey Reid
10/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
10/02/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
09/17/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/05/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/22/2025
Permit issued — General Construction
B00748674-I1-GC
07/15/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Admin
06/24/2025
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P5
05/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Reid
05/26/2025
Special inspection requirement — Insulation placement and R values
Jeffrey Reid
05/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
05/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
03/20/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/02/2025
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P4
02/15/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
02/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
01/31/2025
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P3
01/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
01/23/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
01/14/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/05/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/24/2024
Permit issued — Plumbing
B00748674-S1-PL
06/15/2024
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P2
06/10/2024
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
06/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
02/02/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/31/2023
Objection resolved — Addressed
10/27/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/29/2023
Objection raised — Other
09/27/2023
Permit issued — General Construction
B00748674-I1-GC
09/26/2023
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-S1
09/25/2023
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-P1
09/24/2023
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Reid
09/24/2023
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Reid
09/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Reid
09/24/2023
Special inspection requirement — Insulation placement and R values
Jeffrey Reid
07/19/2022
Filed — Alteration CO
Installation of plumbing fixtures at the first (001) and second (002) floors and removal of the of the tub and boiler at the cellar
B00748674-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedA-MAC OF NEW YORK CONSTRU08/22/2025
DOB NOWPlumbingSigned-offPLBG P & H INC06/24/2024
DOB NOWGeneral ConstructionPermit IssuedA-MAC OF NEW YORK CONSTRU09/27/2023
BISOTISSUEDKAMTECH RESTORATION CORP03/28/2019
BISPLISSUEDPERFECT PLBG & HTG03/21/2006
1 project · most recent 10/13/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/13/2025Signed-offPLBG P & H INCGas, Water/Sanitary
3 projects · most recent 06/06/2026
General Wiring
FiledStatusContractorScope
06/06/2026Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
04/05/2022CompleteFRIED ELECTRIC CO.—
04/05/2019CompleteBERGER QUALITY ELEC'L CON—
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/13/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/17/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/05/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/20/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/14/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/05/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/05/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/02/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/27/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
10/02/2025Fire-Resistance Rated ConstructionJeffrey Reidprogress
10/02/2025Insulation placement and R valuesJeffrey Reidenergy_progress
10/02/2025Fire-Resistant Penetrations and JointsJeffrey Reidspecial
10/02/2025Energy Code Compliance InspectionsJeffrey Reidprogress
05/26/2025Fire-Resistance Rated ConstructionJeffrey Reidprogress
05/26/2025Insulation placement and R valuesJeffrey Reidenergy_progress
05/26/2025Fire-Resistant Penetrations and JointsJeffrey Reidspecial
05/26/2025Energy Code Compliance InspectionsJeffrey Reidprogress
02/15/2025Energy Code Compliance InspectionsJeffrey Reidprogress
02/15/2025Fire-Resistant Penetrations and JointsJeffrey Reidspecial
01/23/2025Fire-Resistant Penetrations and JointsJeffrey Reidspecial
01/23/2025Energy Code Compliance InspectionsJeffrey Reidprogress
06/10/2024Energy Code Compliance InspectionsJeffrey Reidprogress
06/10/2024Fire-Resistant Penetrations and JointsJeffrey Reidspecial
09/24/2023Fire-Resistance Rated ConstructionJeffrey Reidprogress
09/24/2023Energy Code Compliance InspectionsJeffrey Reidprogress
09/24/2023Fire-Resistant Penetrations and JointsJeffrey Reidspecial
09/24/2023Insulation placement and R valuesJeffrey Reidenergy_progress
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/26/2026B00748674-P4Request digital key ↗
08/26/2026B00748674-P3Request digital key ↗
08/26/2026B00748674-P2Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
03/26/2019340667843Open ↗
▸BISWORK PERMIT APPLICATION1
03/28/2019340667843Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00748674-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature12
09/01/2026B00748674-P3Open ↗
08/31/2026B00748674-P4Open ↗
08/28/2026B00748674-P5Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/26/2026B00748674-P4Open ↗
08/26/2026B00748674-P3Open ↗
08/26/2026B00748674-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026B00748674-P3Open ↗
08/31/2026B00748674-P4Open ↗
08/28/2026B00748674-P5Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/26/2019340667843Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
03/26/2019340667843Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/26/2026B00748674-P4Open ↗
08/26/2026B00748674-P3Open ↗
08/26/2026B00748674-P2Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/26/2019340667843Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
05/20/2019340667843Open ↗
03/26/2019340667843Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/20/2019340667843Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
03/26/2019340667843Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
05/20/2019340667843Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
05/20/2019340667843Open ↗
03/26/2019340667843Open ↗
▸Approvals, Objections & Sign-offs3
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
05/20/2019340667843Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/20/2019340667843Open ↗
▸BISThird Party Electrical Signoff Compliance Report1
05/20/2019340667843Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/20/2019340667843Open ↗
03/26/2019340667843Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
03/26/2019340667843Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification4
08/26/2026B00748674-I1Open ↗
08/26/2026B00748674-P5Open ↗
08/26/2026B00748674-P6Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026B00748674-I1Open ↗