← Back
BuildNYC
Shopping center, with or without parking
8925 AVENUE D
BROOKLYN · Canarsie · BIN 3397393
💬 Discuss this project
2010Year Built
1Stories
K6Building Class
M1-1Zoning
7,655 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Shopping center, with or without parking · Owner of record: Breit Canarsie Owner · 7,762 sf lot · 0.99 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofShopcore Properties6p · 3 filings · 20 docs
Floor 1Shopcore Properties7p · 2 filings · 13 docs
Site & exteriorLabcorp5p · 3 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Canarsie Plaza2703/21/2026
Cim Group303/22/2026
Cole MT Brooklyn NY203/21/2026
Dollar Tree103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Peter Rosen, PE407/21/2022
Xu Consulting Engineering212/07/2021
Shaaban Engineering211/12/2021
SBLM Architects109/24/2021
WB Engineers & Consultants109/14/2021
Leon Skvirsky PE112/14/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
National Maintenance403/21/2026
George E Berger Ass1403/21/2026
KM Associates of New York103/21/2026
Building Brothers203/21/2026
K & M Associates103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Full Scale ContractingGeneral Contractor407/08/2026
National MaintenanceElectrical403/21/2026
Montana Electrical DecoratingElectrical203/21/2026
National MaintenanceSign hanger207/08/2026
SRM Electrical ServicesElectrical103/22/2026
Neptune Signs & AwningsSign hanger107/08/2026
Redline ElectricElectrical103/21/2026
Oehler ContractingGeneral Contractor107/08/2026
Home Run ElectricElectrical103/21/2026
SRM Electrical ServicesElectrical103/21/2026
NY Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Catalpa Special Inspectio2004207/07/2022
Autographic Co1579212/07/2021
Crosscheck Inspection Services544109/14/2021
Building Lifecycle
All (67)Filed (11)Permit Issued (8)Signed Off (7)Violation (6)Inspection (4)Objection (6)Special Inspection (25)
07/13/2026
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
02/12/2026
Violation issued (FDNY_ORDER, closed)
02/12/2026
Violation issued (FDNY_ORDER, closed)
02/12/2026
Violation issued (FDNY_ORDER, closed)
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/23/2023
Signed off — Alteration
B00622780-I1
02/23/2023
Signed off — Alteration
B00615015-I1
10/31/2022
Signed off — Alteration
It is proposed to connect gas to new HVAC unit. Application filed in conjunction with B00587180 (General Construction), B00587208 (Structural), and B00587192 (Mechanical). No change of use, egress or occupancy.
B00587226-I1
08/23/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/29/2022
Signed off — Alteration
It is proposed to remove non-load bearing partitions, lighting changes and slab repair as shown on plans. No Change of use, egress or occupancy. Structural, Mechanical, Plumbing changes to be filed under separate applications. See comments for application
B00587180-I1
07/29/2022
Signed off — Alteration
It is proposed to install new HVAC unit and modification to existing ductwork as shown on plans. Application filed in conjunction with B00587180 (General Construction), Structural (XXX), and Plumbing (XXX).
B00587192-I1
07/21/2022
Filed — Alteration
It is proposed to connect gas to new HVAC unit. Application filed in conjunction with B00587180 (General Construction), B00587208 (Structural), and B00587192 (Mechanical). No change of use, egress or occupancy.
B00587226-P1
07/07/2022
Filed — Alteration
It is proposed to install new HVAC unit and modification to existing ductwork as shown on plans. Application filed in conjunction with B00587180 (General Construction), Structural (XXX), and Plumbing (XXX).
B00587192-P1
06/23/2022
Special inspection requirement — Mechanical Systems
ERIC BERLENT
06/23/2022
Special inspection requirement — Shutoff dampers
ERIC BERLENT
06/23/2022
Special inspection requirement — HVAC-R and service water heating equipment
ERIC BERLENT
06/23/2022
Special inspection requirement — HVAC-R and service water heating system controls
ERIC BERLENT
06/23/2022
Special inspection requirement — Maintenance information
ERIC BERLENT
06/23/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ERIC BERLENT
06/23/2022
Special inspection requirement — Final
ERIC BERLENT
06/23/2022
Special inspection requirement — Energy Code Compliance Inspections
ERIC BERLENT
06/16/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/15/2022
Signed off — Alteration
Structural modifications to existing roof to fit new RTU. Infill existing trench slab on grade. no change of use, egress or occupancy. Application filed in conjunction with B00587180 (General Construction), B00587192 (Mechanical) and Plumbing (B00587226).
B00587208-I1
04/21/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/14/2022
Permit issued — General Construction
B00581760-I1-GC
12/08/2021
Permit issued — Structural
B00587208-I1-ST
12/08/2021
Special inspection requirement — Final
ERIC BERLENT
12/08/2021
Special inspection requirement — Structural Steel - Welding
asghar Ghodsi
12/08/2021
Special inspection requirement — Structural Steel - Details
asghar Ghodsi
12/08/2021
Special inspection requirement — Concrete - Cast-In-Place
asghar Ghodsi
12/08/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
asghar Ghodsi
12/07/2021
Filed — Alteration
Structural modifications to existing roof to fit new RTU. Infill existing trench slab on grade. no change of use, egress or occupancy. Application filed in conjunction with B00587180 (General Construction), B00587192 (Mechanical) and Plumbing (B00587226).
B00587208-P1
11/19/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
JOSE FUERTES
11/17/2021
Permit issued — Sign
B00622780-I1-SG
11/15/2021
Permit issued — Sign
B00615015-I1-SG
11/12/2021
Filed — Alteration
B00622780-I1
11/12/2021
Filed — Alteration
B00615015-I1
10/21/2021
Permit issued — Plumbing
B00587226-I1-PL
10/08/2021
Permit issued — Mechanical Systems
B00587192-I1-MS
10/07/2021
Permit issued — General Construction
B00587180-I1-GC
10/07/2021
Special inspection requirement — Concrete - Cast-In-Place
asghar Ghodsi
10/07/2021
Special inspection requirement — Structural Steel - Details
asghar Ghodsi
10/07/2021
Special inspection requirement — Structural Steel - Welding
asghar Ghodsi
10/07/2021
Special inspection requirement — Final
ERIC BERLENT
10/07/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
asghar Ghodsi
10/05/2021
Filed — Alteration
It is proposed to install new HVAC unit and modification to existing ductwork as shown on plans. Application filed in conjunction with B00587180 (General Construction), Structural (XXX), and Plumbing (XXX).
B00587192-I1
10/03/2021
Filed — Alteration
It is proposed to connect gas to new HVAC unit. Application filed in conjunction with B00587180 (General Construction), B00587208 (Structural), and B00587192 (Mechanical). No change of use, egress or occupancy.
B00587226-I1
09/24/2021
Filed — Alteration
It is proposed to remove non-load bearing partitions, lighting changes and slab repair as shown on plans. No Change of use, egress or occupancy. Structural, Mechanical, Plumbing changes to be filed under separate applications. See comments for application
B00587180-I1
09/20/2021
Filed — Alteration
Structural modifications to existing roof to fit new RTU. Infill existing trench slab on grade. no change of use, egress or occupancy. Application filed in conjunction with B00587180 (General Construction), B00587192 (Mechanical) and Plumbing (B00587226).
B00587208-I1
09/15/2021
Objection raised — Structural
09/15/2021
Objection resolved — Addressed
09/15/2021
Objection raised — Scope
09/15/2021
Objection resolved — Addressed
09/15/2021
Objection raised — Energy
09/15/2021
Objection resolved — Addressed
09/14/2021
Filed — Alteration
Installation of new electric vehicle charging station, a small equipment yard adjacent to the station, new electrical distribution, minor site work to install the conduits, equipment pads, and screening around the equipment yard.
B00581760-I1
09/03/2021
Special inspection requirement — Concrete - Cast-In-Place
EUGENE BIFULCO
09/01/2021
Special inspection requirement — Interior lighting power
ERIC BERLENT
09/01/2021
Special inspection requirement — Lighting controls
ERIC BERLENT
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedOehler Contracting02/14/2022
DOB NOWStructuralSigned-offFull Scale Contracting12/08/2021
DOB NOWSignSigned-offNational Maintenance11/17/2021
DOB NOWSignSigned-offNational Maintenance11/15/2021
DOB NOWPlumbingSigned-offNY Plumbing & Heating10/21/2021
DOB NOWMechanical SystemsSigned-offFull Scale Contracting10/08/2021
DOB NOWGeneral ConstructionSigned-offFull Scale Contracting10/07/2021
DOB NOWSignSigned-offNeptune Signs & Awnings12/20/2018
BIS—ISSUEDNorth Shore Neon Sign Co03/05/2014
BISPLISSUEDJTP Plbing Contractor, LT01/23/2014
BISFPISSUEDSentinel Fire Control01/22/2014
BISOTISSUEDAdf Pizza I12/16/2013
BISOTISSUEDValente/C.A. Lindman10/22/2013
BIS—ISSUEDService Sign Erectors Co04/12/2012
BIS—ISSUEDService Sign Erectors Co04/12/2012
BISPLISSUEDMetro Mechanical Group11/30/2011
BISOTISSUEDAcrs II11/30/2011
BISMHISSUEDAcrs II11/30/2011
BISPLISSUEDMetro Mechanical Group08/11/2011
BISMHISSUEDAcrs II08/11/2011
BISOTISSUEDAcrs II08/10/2011
BIS—ISSUEDAcrs II06/09/2011
BISMHISSUEDAcrs II06/09/2011
BISPLISSUEDMetro Mechanical Group11/24/2010
BIS—ISSUEDAcrs II06/30/2010
BISOTRE-ISSUEDAcrs II06/25/2010
BISOTISSUEDAcrs II06/16/2010
BIS—ISSUEDAcrs II06/16/2010
BISEQISSUEDAcrs II06/16/2010
BISMHISSUEDAcrs II06/15/2010
BISOTISSUEDAcrs II06/15/2010
BISEQISSUEDCityview Masonry06/01/2010
BISSPISSUEDCurrent Fire Protection05/20/2010
BISOTISSUEDAcrs03/26/2010
BISMHISSUEDAcrs11/17/2009
BIS—ISSUEDAcrs07/30/2009
BISOTISSUEDAcrs06/18/2009
BISOTISSUEDAcrs06/18/2009
BIS—ISSUEDAcrs02/13/2009
BISEQISSUEDAcrs02/12/2009
+ 2 more permits on file
10 projects · most recent 04/22/2024
General Wiring
FiledStatusContractorScope
04/22/2024CompleteSRM Electrical ServiceGeneral Wiring
04/15/2024CompleteSRM Electrical Service—
07/13/2023CompleteSRM Electrical Services1 meters
06/18/2022CompleteSRM Electrical Service—
04/12/2022Permit IssuedHome Run ElectricGeneral Wiring
12/01/2021Permit IssuedNational Maintenance—
11/30/2021Permit IssuedNational Maintenance—
04/28/2021CompleteSRM Electrical Services—
11/20/2020CompleteSRM Electrical Services—
02/01/2019CompleteRobert S. Covello—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/13/2026Fail-Final Construction Permit WithdrawalFailView ↗
08/23/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/16/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/21/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
06/23/2022Mechanical SystemsERIC BERLENTspecial
06/23/2022Shutoff dampersERIC BERLENTenergy_progress
06/23/2022HVAC-R and service water heating equipmentERIC BERLENTenergy_progress
06/23/2022HVAC-R and service water heating system controlsERIC BERLENTenergy_progress
06/23/2022Maintenance informationERIC BERLENTenergy_progress
06/23/2022HVAC-R and service water piping design and insulationERIC BERLENTenergy_progress
06/23/2022FinalERIC BERLENTprogress
06/23/2022Energy Code Compliance InspectionsERIC BERLENTprogress
12/08/2021FinalERIC BERLENTprogress
12/08/2021Structural Steel - Weldingasghar Ghodsispecial
12/08/2021Structural Steel - Detailsasghar Ghodsispecial
12/08/2021Concrete - Cast-In-Placeasghar Ghodsispecial
12/08/2021Structural Stability – Alterations of existing buildingsasghar Ghodsispecial
11/19/2021Subsurface Investigations (Borings/Test Pits)JOSE FUERTESspecial
10/07/2021Concrete - Cast-In-Placeasghar Ghodsispecial
10/07/2021Structural Steel - Detailsasghar Ghodsispecial
10/07/2021Structural Steel - Weldingasghar Ghodsispecial
10/07/2021FinalERIC BERLENTprogress
10/07/2021Structural Stability – Alterations of existing buildingsasghar Ghodsispecial
09/03/2021Concrete - Cast-In-PlaceEUGENE BIFULCOspecial
09/01/2021Interior lighting powerERIC BERLENTenergy_progress
09/01/2021Lighting controlsERIC BERLENTenergy_progress
09/01/2021Energy Code Compliance InspectionsERIC BERLENTprogress
09/01/2021FinalERIC BERLENTprogress
08/23/2021FinalDesmond Greeneprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
LabcorpMedical / Healthcare—
Project B00615015 Alteration · LOC Issued · 11/12/2021
Project B00622780 Alteration · LOC Issued · 11/12/2021
EVgoAutomotive / fuel—
Project B00581760 Alteration · Filing Withdrawn · 09/14/2021
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 294 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
09/02/2026B00098728-I1Request digital key ↗
09/01/2026B00587208-P1Request digital key ↗
09/01/2026B00587208-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits54
▸BISWORK PERMIT APPLICATION29
07/17/2014320826406Open ↗
01/24/2014320474688Open ↗
12/20/2013320474688Open ↗
Showing 3 of 29 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION25
11/29/2018340648099Open ↗
07/17/2014320826406Open ↗
01/09/2014320870946Open ↗
Showing 3 of 25 on file for this type
▸Seals & Professional Certifications88
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION41
07/17/2014320826406Open ↗
06/26/2014320826406Open ↗
01/09/2014320870946Open ↗
Showing 3 of 41 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
09/02/2026B00098728-I1Open ↗
09/01/2026B00581760-I1Open ↗
09/01/2026B00587208-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/01/2026B00587192-P1Open ↗
08/28/2026B00587208-P1Open ↗
08/28/2026B00587208-P1Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST8
07/17/2014320826406Open ↗
12/20/2013320474688Open ↗
11/12/2013320836707Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/01/2026B00587192-P1Open ↗
09/01/2026B00587192-P1Open ↗
08/28/2026B00587208-P1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
04/18/2012320461870Open ↗
04/16/2012320461889Open ↗
Showing 2 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
07/17/2014320826406Open ↗
12/20/2013320474688Open ↗
11/12/2013320836707Open ↗
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/29/2018340648099Open ↗
▸Trade Schedules & Equipment27
▸BISSCHEDULE B - PLUMBING10
11/29/2018340648099Open ↗
12/20/2013320474688Open ↗
02/02/2012320363959Open ↗
Showing 3 of 10 on file for this type
▸BISSELF-CERT PLUMBING NOTICE9
06/06/2014320474688Open ↗
03/06/2012320363959Open ↗
01/09/2012320363959Open ↗
Showing 3 of 9 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
05/19/2014320870946Open ↗
05/09/2011320258760Open ↗
▸BISWATER METER PERMIT : DEP-METER2
05/24/2011320105444Open ↗
04/28/2011320105444Open ↗
▸BISEQUIPMENT USE PERMITS1
10/20/2011320094107Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B1
05/24/2011320105444Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
10/12/2011320094107Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
04/28/2011320105444Open ↗
▸Environmental & Asbestos9
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER6
11/12/2013320836707Open ↗
01/10/2011320258760Open ↗
Showing 2 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
11/29/2018340648099Open ↗
01/09/2014320870946Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance16
▸BISTECHNICAL REPORT: ENERGY8
04/18/2012320461870Open ↗
04/16/2012320461889Open ↗
03/08/2012320363959Open ↗
Showing 3 of 8 on file for this type
▸BISEN2 - As Built Energy Analysis4
03/23/2012320363959Open ↗
11/16/2011320332387Open ↗
03/08/2012320363959Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.2
09/01/2026B00587180-I1Open ↗
09/01/2026B00587192-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/20/2013320474688Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/29/2018340648099Open ↗
▸Inspections & Test Reports15
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX4
11/12/2013320836707Open ↗
07/27/2010310085163Open ↗
07/02/2010310220819Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER4
11/12/2013320836707Open ↗
03/14/2011310220819Open ↗
07/02/2010310220819Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: PILE DRIVING2
09/09/2010310085163Open ↗
09/09/2010310085163Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/29/2018340648099Open ↗
▸BISHYDRO FLOW TEST LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWSOIL REPORT1
08/14/2026B00581760-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/14/2026B00581760-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/14/2026B00581760-I1Open ↗
▸Approvals, Objections & Sign-offs40
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST17
06/26/2014320826406Open ↗
01/16/2013320461889Open ↗
10/31/2012320461870Open ↗
Showing 3 of 17 on file for this type
▸BISADMINISTRATIVE OBJECTIONS12
07/17/2014320826406Open ↗
12/20/2013320474688Open ↗
11/12/2013320836707Open ↗
Showing 3 of 12 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION8
05/19/2014320870946Open ↗
11/13/2013320836707Open ↗
10/01/2011310085163Open ↗
Showing 3 of 8 on file for this type
▸BISTAP LETTER - FIRE SVC : DEP-FIRE3
07/07/2011320094107Open ↗
05/24/2011320105444Open ↗
04/28/2011320105444Open ↗
▸Cost, Insurance & Ownership13
▸BISCOST AFFIDAVIT13
11/29/2018340648099Open ↗
07/17/2014320826406Open ↗
06/26/2014320826406Open ↗
Showing 3 of 13 on file for this type
▸Filing & Intake Forms20
▸BISEFILING COVER SHEET13
07/17/2014320826406Open ↗
01/09/2014320870946Open ↗
12/20/2013320474688Open ↗
Showing 3 of 13 on file for this type
▸BISADDITIONAL INFORMATION6
01/03/2019340648099Open ↗
01/03/2019340648099Open ↗
12/14/2018340648099Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
11/29/2018340648099Open ↗
▸Other Documents1
▸BISLOCAL LAW - SUPPPORTING DOCUMENTATION1
11/13/2013320836707Open ↗