← Back
Two stories - detached, small or mid-size
9 CENTER DRIVE MALBA
QUEENS · BIN 4101286
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R1-2Zoning
2,496 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 9,238 sf lot · 0.27 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar3p · 1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
2L ENGINEERING, DPC502/20/2025
PBA ENGINEERING, PC.307/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL CITY REMODELING, INCGeneral Contractor307/08/2026
D.D.S. MECH PBG&HTG CORPPlumbing107/08/2026
GO PRO PLUMBING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RICHARD H. BALSER ENGINEE3028307/27/2021
Building Lifecycle
All (26)Filed (8)Permit Issued (4)Signed Off (2)Inspection (2)Objection (2)Special Inspection (8)
04/03/2025
Signed off — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-I1
03/24/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/20/2025
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-P4
01/07/2025
Objection resolved — Addressed
11/18/2024
Objection raised — Admin
11/06/2024
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-P3
09/11/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/20/2024
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-P2
05/24/2024
Permit issued — Plumbing
Q00836123-I1-PL
04/01/2024
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-P1
05/11/2023
Permit issued — Plumbing
Q00836123-I1-PL
03/28/2023
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY..
Q00836123-I1
08/31/2021
Signed off — Alteration
INSTALL RETAINING WALL ON PROPERTY LINE AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q00448748-I1
07/27/2021
Filed — Alteration
INSTALL RETAINING WALL ON PROPERTY LINE AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q00448748-P2
07/08/2021
Special inspection requirement — Final
Paul Beck
07/08/2021
Special inspection requirement — Concrete - Cast-In-Place
Balser Richard
07/08/2021
Special inspection requirement — Masonry
Balser Richard
07/08/2021
Special inspection requirement — Energy Code Compliance
Balser Richard
04/09/2021
Filed — Alteration
INSTALL RETAINING WALL ON PROPERTY LINE AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q00448748-P1
04/09/2021
Special inspection requirement — Concrete - Cast-In-Place
Balser Richard
04/09/2021
Special inspection requirement — Masonry
Balser Richard
04/09/2021
Special inspection requirement — Energy Code Compliance
Balser Richard
04/09/2021
Special inspection requirement — Final
Paul Beck
04/05/2021
Permit issued — Structural
Q00448748-I1-ST
03/22/2021
Permit issued — Structural
Q00448748-I1-ST
01/19/2021
Filed — Alteration
INSTALL RETAINING WALL ON PROPERTY LINE AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q00448748-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offD.D.S. MECH PBG&HTG CORP05/24/2024
DOB NOWPlumbingSigned-offGO PRO PLUMBING AND HEATI05/11/2023
DOB NOWStructuralSigned-offALL CITY REMODELING, INC04/05/2021
DOB NOWStructuralSigned-offALL CITY REMODELING, INC03/22/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/11/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/08/2021FinalPaul Beckprogress
07/08/2021Concrete - Cast-In-PlaceBalser Richardspecial
07/08/2021MasonryBalser Richardspecial
07/08/2021Energy Code ComplianceBalser Richardprogress
04/09/2021Concrete - Cast-In-PlaceBalser Richardspecial
04/09/2021MasonryBalser Richardspecial
04/09/2021Energy Code ComplianceBalser Richardprogress
04/09/2021FinalPaul Beckprogress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch5
08/21/2026Q00836123-I1Request digital key ↗
08/21/2026Q00836123-P4Request digital key ↗
08/21/2026Q00836123-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Structural3
08/27/2026Q00448748-I1Request digital key ↗
08/15/2026Q00448748-P1Request digital key ↗
08/15/2026Q00448748-P2Request digital key ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/27/2026Q00448748-I1Open ↗
08/27/2026Q00448748-P1Open ↗
08/27/2026Q00448748-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/20/2026Q00448748-P2Open ↗
09/20/2026Q00448748-P2Open ↗
09/01/2026Q00448748-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/20/2026Q00448748-P2Open ↗
09/20/2026Q00448748-P2Open ↗
09/01/2026Q00448748-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026Q00836123-P4Open ↗
08/21/2026Q00836123-P2Open ↗
08/21/2026Q00836123-P1Open ↗