← Back
BuildNYC
Two stories - detached, small or mid-size
9 HEINZ AVENUE
STATEN ISLAND · BIN 5068354
💬 Discuss this project
1930Year Built
1.75Stories
A1Building Class
R3-1Zoning
968 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.24 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 25p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar5p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Design Fencing807/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Michael A. Biagioli, Architect505/13/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Doreen A. Rizzi, Consultant1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Design Fence of NYGeneral Contractor107/08/2026
Capital Contracting P&HPlumbing107/08/2026
Building Lifecycle
09/05/2024
Signed off — Alteration
APPLICATION FOR THE RENOVATION TO EXISTING KITCHEN AND BATHROOMS TO INCLUDE NEW GAS APPLIANCES AND REPLACEMENT OF THE EXISTING PLUMBING FIXTURES AS PER PLAN. NOTE: THERE IS NO ADDITIONAL FLOOR AREA OR LOT COVERAGE. THERE ARE NO NEW PARTITIONS CONSTRUCTED
S01011061-I1
09/04/2024
Signed off — Alteration
APPLICATION FOR THE RENOVATION TO EXISTING KITCHEN AND BATHROOMS TO INCLUDE NEW GAS APPLIANCES AND REPLACEMENT OF THE EXISTING PLUMBING FIXTURES AS PER PLAN. NOTE: THERE IS NO ADDITIONAL FLOOR AREA OR LOT COVERAGE. THERE ARE NO NEW PARTITIONS CONSTRUCTED
S01011061-S1
05/17/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/14/2024
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
05/14/2024
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
27 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDesign Fence of NY03/12/2024
DOB NOWPlumbingSigned-offCapital Contracting P&H03/11/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/17/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/01/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/24/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/11/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/14/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
05/14/2024Energy Code Compliance Inspectionsanthony santoroprogress
05/14/2024HVAC-R and service water heating equipmentanthony santoroenergy_progress
05/14/2024Maintenance informationanthony santoroenergy_progress
05/14/2024HVAC-R and service water heating system controlsanthony santoroenergy_progress
05/14/2024Permanent certificateanthony santoroenergy_progress
05/14/2024HVAC-R and service water piping design and insulationanthony santoroenergy_progress
04/17/2024Finalanthony santoroprogress
04/12/2024HVAC-R and service water heating equipmentanthony santoroenergy_progress
04/12/2024Permanent certificateanthony santoroenergy_progress
04/12/2024HVAC-R and service water heating system controlsanthony santoroenergy_progress
04/12/2024Maintenance informationanthony santoroenergy_progress
04/12/2024HVAC-R and service water piping design and insulationanthony santoroenergy_progress
04/12/2024Energy Code Compliance Inspectionsanthony santoroprogress
20 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account