← Back
Elevator apt, semi-fireproof without stores
9 WEST 64 STREET
MANHATTAN · BIN 1028136
💬 Discuss this project
1930Year Built
6Stories
D1Building Class
R10AZoning
21,528 sfGross Floor Area
35Units
Rent Stabilized3 Open Violations ▸FISP: SAFE
Elevator apt, semi-fireproof without stores · Owner of record: NINE WEST COMPANY, LLC · 5,021 sf lot · 4.29 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
BulkheadUnder Construction2p · 2 filings · 19 docs
Floor 12p · 2 filings · 20 docs
Cellar12p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PRAT ENTERPRISES1409/18/2026
NINE WEST COMPANY1403/22/2026
NINE WEST COMPANY LLC TRI103/22/2026
LV REALTY403/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PRAT ENTERPRISES203/21/2026
Rigid Structural Design, LLC503/21/2026
OUTSOURCE CONSULTANTS, INC.103/21/2026
BMB BUILDING CONSULTING1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TIBER LLCGeneral Contractor1203/21/2026
PRAT ENTERPRISES CORPGeneral Contractor609/18/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
OUTSOURCE SPECIAL INSPECT2827209/16/2026
STEEL CORE ENGINEERING PL1098403/23/2023
TECNICO SPECIAL INSPECTIO5939307/15/2022
Building Lifecycle
All (144)Filed (17)Permit Issued (12)Signed Off (6)Facade (FISP) (12)Violation (39)Inspection (10)Objection (18)Special Inspection (30)
09/17/2026
Permit issued — Sidewalk Shed
M01281256-I1-SH
09/16/2026
Filed — Alteration
TEMPORARY STRUCTURAL BRACING AND PARTIAL DEMOLITION (MEANS & METHODS) DURING FACADE REPAIRS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01232443-S1
09/14/2026
Permit issued — Supported Scaffold
M01281178-I1-SF
09/09/2026
Special inspection requirement — Final
JONAR MADRIAGA
09/09/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
JONAR MADRIAGA
09/09/2026
Special inspection requirement — Tenant Protection Plan Compliance
JONAR MADRIAGA
08/24/2026
Permit issued — General Construction
M01232443-I1-GC-CX
08/21/2026
Objection resolved — Resolved
08/14/2026
Filed — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01281178-P1
08/14/2026
Filed — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01281256-P1
08/14/2026
Permit issued — Suspended Scaffold
M01279764-I1-SC
08/12/2026
Objection raised — Other
08/05/2026
Filed — Alteration
INSTALLATION AND USE OF SUSPENDED SCAFFOLD FOR FACADE RESTORATION/ INSPECTION AS PER PLANS SUBMITTED
M01441696-I1
07/14/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/14/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/18/2025
Violation issued (HPD, closed)
B
12/18/2025
Violation issued (HPD, closed)
C
09/16/2025
Permit issued — Sidewalk Shed
M01281256-I1-SH
09/16/2025
Permit issued — Supported Scaffold
M01281178-I1-SF
09/15/2025
Filed — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01281178-I1
09/15/2025
Filed — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01281256-I1
08/29/2025
Filed — Alteration
INSTALLATION AND USE OF SUSPENDED SCAFFOLD FOR FACADE RESTORATION/ INSPECTION AS PER PLANS SUBMITTED
M01279764-I1
07/02/2025
Filed — Alteration
TEMPORARY STRUCTURAL BRACING AND PARTIAL DEMOLITION (MEANS & METHODS) DURING FACADE REPAIRS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01232443-I1
06/23/2025
Special inspection requirement — Post-installed Anchors
JONAR MADRIAGA
06/23/2025
Special inspection requirement — Tenant Protection Plan Compliance
JONAR MADRIAGA
06/23/2025
Special inspection requirement — Energy Code Compliance Inspections
Nicholas Ferrara
06/23/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
JONAR MADRIAGA
06/23/2025
Special inspection requirement — Masonry
JONAR MADRIAGA
05/28/2025
Special inspection requirement — Final
Nicholas Ferrara
05/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
JONAR MADRIAGA
01/14/2025
Signed off — Alteration
M00450877-I1
01/08/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/19/2024
Signed off — Alteration
Propose Foundation scope of works in conjunction with Alt I NW application ## 121209272.
M00450791-I1
03/28/2024
Violation issued (HPD, open)
C
03/14/2024
Signed off — Alteration
M00457936-I1
03/04/2024
Violation issued (HPD, closed)
B
03/04/2024
Violation issued (HPD, closed)
C
03/04/2024
Violation issued (HPD, closed)
B
03/04/2024
Violation issued (HPD, closed)
B
12/13/2023
Signed off — Alteration
PROPOSE PLUMBING SCOPE OF WORK TO ADD ACCESSORY LAUNDRY ROOM FILED IN CONJUNCTION WITH GC JOB #M00450877 & ALT I NO WORK JOB # 121209272.
M00457947-I1
12/13/2023
Signed off — Alteration
Propose Structural and Partial Demolition work filed in conjunction Alt I Application # 121209272 _. Work consist of cellar infill of existing court to create laundry room. Scope of work includes CMU shear walls, and concrete metal deck with wood plank.
M00449856-I1
11/01/2023
Violation issued (HPD, closed)
C
11/01/2023
Violation issued (HPD, closed)
C
05/05/2023
Special inspection requirement — Mechanical Systems
Alexander Sheyman
05/05/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
05/05/2023
Special inspection requirement — Energy Code Compliance Inspections
Alexander Sheyman
05/05/2023
Special inspection requirement — Final
Alexander Sheyman
05/05/2023
Special inspection requirement — HVAC-R and service water heating system controls
Alexander Sheyman
05/05/2023
Special inspection requirement — HVAC-R and service water heating equipment
Alexander Sheyman
05/05/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Sheyman
05/05/2023
Special inspection requirement — Maintenance information
Alexander Sheyman
04/21/2023
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
04/21/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/14/2023
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
04/14/2023
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
04/03/2023
Permit issued — Plumbing
M00457947-I1-PL
03/23/2023
Filed — Alteration
M00457936-P1
Latest 60 of 144 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedPRAT ENTERPRISES CORP09/17/2026
DOB NOWSupported ScaffoldPermit IssuedPRAT ENTERPRISES CORP09/14/2026
DOB NOWGeneral ConstructionPermit IssuedPRAT ENTERPRISES CORP08/24/2026
DOB NOWSuspended ScaffoldPermit IssuedPRAT ENTERPRISES CORP08/14/2026
DOB NOWSidewalk ShedPermit IssuedPRAT ENTERPRISES CORP09/16/2025
DOB NOWSupported ScaffoldPermit IssuedPRAT ENTERPRISES CORP09/16/2025
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP04/03/2023
DOB NOWSidewalk ShedSigned-offPRAT ENTERPRISES CORP10/17/2022
DOB NOWStructuralSigned-offTIBER LLC09/27/2022
DOB NOWGeneral ConstructionSigned-offTIBER LLC09/27/2022
DOB NOWFoundationSigned-offTIBER LLC09/27/2022
DOB NOWMechanical SystemsSigned-offTIBER LLC09/27/2022
BIS—ISSUEDTIBER LLC09/26/2022
BISEQISSUEDPOWERS BRIDGING & SCAFFOLDING03/21/2008
BISOTISSUEDDNA CONTRACTING LLC03/18/2008
BISOTISSUEDDNA CONTRACTING LLC02/15/2008
BISEQISSUEDPOWERS BRIDGING & SCAFFOLDING12/13/2007
BISEQISSUEDPOWERS BRIDGING & SCAFFOLDING02/15/2007
BISEQISSUEDPOWERS BRIDGING & SCAFFOLDING05/19/2005
BISFBISSUEDSTAR INDUSTRIAL SERV CO INC08/22/1997
BISEQRE-ISSUEDROCKLEDGE SCAFFOLDING CORP06/15/1993
BISEQRE-ISSUEDPOWERS GENERAL CONST08/15/1990
4 projects · most recent 07/21/2026
General Wiring
FiledStatusContractorScope
07/21/2026Permit IssuedAURORA ELECL CONTG INC—
06/23/2026Permit IssuedAURORA ELECL CONTG INC—
06/21/2023CompleteBRANDL ELECTRIC INC.General Wiring
10/18/2022CompleteSTEVEN FARKAS—
1 project · most recent 09/16/2026
FiledStatusContractorScope
09/16/2026Permit IssuedPRAT ENTERPRISES CORP2 scope_items
2 projects · most recent 08/14/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
08/14/2026Permit IssuedPRAT ENTERPRISES CORPScaffold
08/14/2026Permit IssuedPRAT ENTERPRISES CORPSidewalk Shed
2 projects · most recent 08/05/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
08/05/2026——Suspended Scaffold (SC)
08/29/2025Permit IssuedPRAT ENTERPRISES CORPSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
07/14/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/14/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/14/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/08/2025Pass-Final General Construction Non-Directive 14PassView ↗
04/21/2023Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
04/21/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/14/2023Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
04/14/2023Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
09/09/2026FinalJONAR MADRIAGAprogress
09/09/2026Structural Stability – Alterations of existing buildingsJONAR MADRIAGAspecial
09/09/2026Tenant Protection Plan ComplianceJONAR MADRIAGAspecial
06/23/2025Post-installed AnchorsJONAR MADRIAGAspecial
06/23/2025Tenant Protection Plan ComplianceJONAR MADRIAGAspecial
06/23/2025Energy Code Compliance InspectionsNicholas Ferraraprogress
06/23/2025Construction Operations Influencing Adjacent StructuresJONAR MADRIAGAspecial
06/23/2025MasonryJONAR MADRIAGAspecial
05/28/2025FinalNicholas Ferraraprogress
05/28/2025Structural Stability – Alterations of existing buildingsJONAR MADRIAGAspecial
05/05/2023Mechanical SystemsAlexander Sheymanspecial
05/05/2023Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
05/05/2023Energy Code Compliance InspectionsAlexander Sheymanprogress
05/05/2023FinalAlexander Sheymanprogress
05/05/2023HVAC-R and service water heating system controlsAlexander Sheymanenergy_progress
05/05/2023HVAC-R and service water heating equipmentAlexander Sheymanenergy_progress
05/05/2023HVAC-R and service water piping design and insulationAlexander Sheymanenergy_progress
05/05/2023Maintenance informationAlexander Sheymanenergy_progress
07/20/2022Preliminary—progress
07/20/2022Masonry—special
07/20/2022Structural Cold-Formed Steel—special
07/20/2022Structural Stability – Alterations of existing buildings—special
07/20/2022Structural Steel - Details—special
07/20/2022Structural Steel - High Strength Bolting—special
07/20/2022Structural Steel - Welding—special
Latest 25 of 41.
▾Documents — 135 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch8
09/01/2026M08020924-I1Request digital key ↗
08/23/2026M01232443-I1Request digital key ↗
08/21/2026M01279764-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/02/2026M00457936-I1Request digital key ↗
08/15/2026M00457936-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026M00457947-P1Request digital key ↗
08/14/2026M00457947-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural2
08/15/2026M00449856-I1Request digital key ↗
08/15/2026M00449856-P1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
09/04/2026M00450877-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Foundation1
08/14/2026M00450791-I1Request digital key ↗
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION12
05/12/2025121209272Open ↗
05/05/2025121209272Open ↗
12/19/2024101842268Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION3
09/26/2022121209272Open ↗
03/20/2008110080643Open ↗
02/15/2008110080643Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
09/19/2022121209272Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
09/19/2022121209272Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
07/24/2023121209272Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026M00450791-I1Open ↗
08/13/2026M00450877-I1Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
05/20/2025121209272Open ↗
▸BISVERIFY TAX LOT1
03/20/2025121209272Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
05/20/2025121209272Open ↗
▸Seals & Professional Certifications45
▸DOB NOWDPL-1: Design Professional Seal & Signature16
09/22/2026M01232443-S1Open ↗
09/02/2026M00457947-P1Open ↗
09/02/2026M00457947-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/23/2026M01232443-S1Open ↗
09/23/2026M01232443-S1Open ↗
08/28/2026M00457936-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/23/2026M01232443-S1Open ↗
08/28/2026M00457936-I1Open ↗
08/28/2026M00457936-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
11/02/2011120881402Open ↗
07/15/2009110080643Open ↗
02/15/2008110080643Open ↗
Showing 3 of 4 on file for this type
▸BISPC FULL REPORT1
02/05/2008110080643Open ↗
▸Trade Schedules & Equipment2
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
04/15/2025121209272Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026M00450877-I1Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/05/2021121209272Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
09/19/2022121209272Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/14/2026M00457947-I1Open ↗
08/13/2026M00450791-I1Open ↗
08/13/2026M00457936-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/22/2026M01232443-S1Open ↗
08/13/2026M01232443-I1Open ↗
▸BISASBESTOS INSPECTION REPORT1
02/05/2008110080643Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026M00450877-I1Open ↗
08/13/2026M00457936-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/14/2025121209272Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Plot Diagram1
08/13/2026M00450791-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026M00450791-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026M00450791-I1Open ↗
▸Approvals, Objections & Sign-offs9
▸BISSCHEDULE A - OCCUPANCY / USE3
05/05/2025121209272Open ↗
02/05/2021121209272Open ↗
11/02/2011120881402Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION3
04/07/2025101842268Open ↗
03/06/2025101842268Open ↗
07/07/2022121209272Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
11/02/2011120881402Open ↗
01/31/2008110080643Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/15/2009110080643Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT4
11/02/2011120881402Open ↗
07/15/2009110080643Open ↗
04/29/2009110080643Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
03/20/2025121209272Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026M00450877-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026M00450877-I1Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION4
03/29/2024121209272Open ↗
07/29/2022121209272Open ↗
07/07/2022121209272Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
01/21/2021121209272Open ↗
11/02/2011120881402Open ↗
▸Other Documents11
▸DOB NOWManufacturer's Specifications2
08/15/2026M01441696-I1Open ↗
08/13/2026M01279764-I1Open ↗
▸DOB NOWCalculations2
08/15/2026M01441696-I1Open ↗
08/13/2026M01279764-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026M00450791-I1Open ↗
08/13/2026M00450877-I1Open ↗
▸BISPLOT DIAGRAM1
02/05/2021121209272Open ↗
▸BISDHCR DOCUMENT1
04/07/2025101842268Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026M00450877-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026M00450877-I1Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/23/2026M01232443-I1Open ↗