← Back
Two stories - detached, small or mid-size
90-08 197 STREET
QUEENS · BIN 4222456
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R4Zoning
1,612 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,025 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 11 docs
Floor 21p · 1 filing · 11 docs
Floor 1
Cellar1p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/02/2015$428K—Private party → Private party$266/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMIL COPPIN ARCHITECT PC308/25/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FAMILY HOME IMPROVEMENT CORPGeneral Contractor108/21/2026
Building Lifecycle
All (42)Filed (3)Permit Issued (1)Objection (13)Special Inspection (25)
08/20/2026
Permit issued — Construction Fence
Q01272149-I1-FN
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
09/18/2025
Objection raised — Fire_Protection
09/18/2025
Objection raised — Inspections
09/18/2025
Objection raised — Admin
09/18/2025
Objection raised — Other
09/18/2025
Objection raised — Inspections
09/18/2025
Objection raised — Inspections
09/04/2025
Objection resolved — Addressed
08/28/2025
Objection raised — Admin
08/25/2025
Filed — Alteration
Installation of Construction Fence
Q01272149-I1
08/25/2025
Filed — Alteration CO
Installation of Plumbing Fixtures, Gas Fixtures, and Storm Drainage to Drywell
Q01145757-S1
03/04/2025
Special inspection requirement — Duct leakage testing, insulation and design
03/04/2025
Special inspection requirement — Electric vehicle service equipment requirements
12/24/2024
Filed — Alteration CO
Installation of Plumbing Fixtures, Gas Fixtures, and Storm Drainage to Drywell
Q01145757-I1
11/21/2024
Special inspection requirement — Concrete - Cast-In-Place
11/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/21/2024
Special inspection requirement — Subgrade Inspections
11/21/2024
Special inspection requirement — Final
11/21/2024
Special inspection requirement — Footing and Foundation
11/21/2024
Special inspection requirement — Energy Code Compliance Inspections
11/21/2024
Special inspection requirement — Fire-Resistance Rated Construction
11/21/2024
Special inspection requirement — Preliminary
11/21/2024
Special inspection requirement — Structural Wood Frame
11/21/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
11/21/2024
Special inspection requirement — Mechanical Systems
11/21/2024
Special inspection requirement — HVAC-R and service water heating system controls
11/21/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
11/21/2024
Special inspection requirement — Interior lighting power
11/21/2024
Special inspection requirement — Air barrier - visual inspection
11/21/2024
Special inspection requirement — Maintenance information
11/21/2024
Special inspection requirement — Insulation placement and R values
11/21/2024
Special inspection requirement — Fenestration air leakage
11/21/2024
Special inspection requirement — Metering
11/21/2024
Special inspection requirement — HVAC-R and service water heating equipment
11/21/2024
Special inspection requirement — Permanent certificate
11/21/2024
Special inspection requirement — Fenestration areas
11/21/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedFAMILY HOME IMPROVEMENT CORP08/20/2026
1 project · most recent 08/25/2025
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2025——Air Conditioning Systems, Heating Systems
Cooling
Fujitsu 15 LZAS1B 12,000 BTU · Vrf Indoor ×5
Fujitsu 15 LZAS1B 14,000 BTU · Heat Pump Outdoor ×3
Fujitsu AOU36LXFZ1 36,000 BTU · Heat Pump Outdoor ×3
Heating
Fujitsu Fujitsu 15 LZAS1B and 12 LZAS1B 12,000 BTU · Heat Pump Outdoor ×8
1 project · most recent 08/25/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/25/2025——Gas, Storm, Water/Sanitary
1 project · most recent 08/25/2025
Wood
FiledStatusContractorScope
08/25/2025——Wood
1 project · most recent 08/25/2025
Fence
FiledStatusContractorScope
08/25/2025Permit IssuedFAMILY HOME IMPROVEMENT CFence
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
03/04/2025Duct leakage testing, insulation and design—energy_progress
03/04/2025Electric vehicle service equipment requirements—energy_progress
11/21/2024Concrete - Cast-In-Place—special
11/21/2024Fire-Resistant Penetrations and Joints—special
11/21/2024Subgrade Inspections—special
11/21/2024Final—progress
11/21/2024Footing and Foundation—progress
11/21/2024Energy Code Compliance Inspections—progress
11/21/2024Fire-Resistance Rated Construction—progress
11/21/2024Preliminary—progress
11/21/2024Structural Wood Frame—progress
11/21/2024Fenestration and door U-factor and product ratings—energy_progress
11/21/2024Mechanical Systems—special
11/21/2024HVAC-R and service water heating system controls—energy_progress
11/21/2024HVAC-R and service water piping design and insulation—energy_progress
11/21/2024Interior lighting power—energy_progress
11/21/2024Air barrier - visual inspection—energy_progress
11/21/2024Maintenance information—energy_progress
11/21/2024Insulation placement and R values—energy_progress
11/21/2024Fenestration air leakage—energy_progress
11/21/2024Metering—energy_progress
11/21/2024HVAC-R and service water heating equipment—energy_progress
11/21/2024Permanent certificate—energy_progress
11/21/2024Fenestration areas—energy_progress
11/21/2024Structural Stability – Alterations of existing buildings—special
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026Q01145757-I1Request digital key ↗
08/19/2026Q01272149-I1Request digital key ↗
08/15/2026Q01145757-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01145757-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01145757-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026Q01145757-S1Open ↗
08/21/2026Q01145757-I1Open ↗
08/19/2026Q01272149-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/21/2026Q01145757-I1Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram1
08/13/2026Q01145757-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/21/2026Q01145757-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01145757-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01145757-I1Open ↗