← Back
Two stories - detached, small or mid-size
90-15 205 STREET
QUEENS · Hollis · BIN 4223173
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,723 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,342 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
AtticUnder Construction5p · 1 filing · 20 docs
Floor 2Under Construction14p · 1 filing · 20 docs
Floor 1Under Construction12p · 1 filing · 20 docs
CellarUnder Construction13p · 1 filing · 20 docs
Site & exteriorUnder Construction19p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/05/2024$670K—— → —$389/sf building
12/18/2023$555K—— → —$322/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOLANKI ENGINEERING, PC402/28/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
R&R CONTRACTING MGMT CORPGeneral Contractor303/21/2026
VILLAGE ELECTL CONTRS INCElectrical103/22/2026
CUSTOMBUILT HOMES INCGeneral Contractor107/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP CONCRETE TESTING AND I6252202/28/2025
SOLANKI ENGINEERING, P.C.8451302/28/2025
Building Lifecycle
All (31)Filed (4)Permit Issued (3)Inspection (4)Objection (12)Special Inspection (8)
03/13/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/13/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/28/2025
Filed — Alteration CO
SUBSEQUENT FILING FOR THE INSTALLATION OF NEW PLUMBING FIXTURES THROUGHOUT BUILDING AND DRYWELL IN OPEN SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01042730-P1
02/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ashray Solanki
02/21/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Ashray Solanki
02/21/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
INDARDEO PARBHUNATH
02/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Ashray Solanki
02/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
Ashray Solanki
02/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Ashray Solanki
02/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
Ashray Solanki
02/21/2025
Special inspection requirement — Maintenance information
Ashray Solanki
02/04/2025
Permit issued — Plumbing
Q01042730-S1-PL
11/19/2024
Permit issued — General Construction
Q01042730-I1-GC-CX
11/14/2024
Objection resolved — Addressed
11/08/2024
Objection resolved — Addressed
11/07/2024
Objection raised — Zoning
11/07/2024
Objection raised — Zoning
11/07/2024
Objection resolved — Addressed
08/08/2024
Objection resolved — Addressed
07/30/2024
Permit issued — Construction Fence
Q01042730-S2-FN
07/26/2024
Objection resolved — Addressed
07/26/2024
Objection resolved — Addressed
06/17/2024
Objection raised — Zoning
06/17/2024
Objection raised — Zoning
06/17/2024
Objection raised — Admin
06/17/2024
Objection raised — Structural
06/15/2024
Filed — Alteration CO
SUBSEQUENT FILING FOR THE INSTALLATION OF NEW PLUMBING FIXTURES THROUGHOUT BUILDING AND DRYWELL IN OPEN SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01042730-S1
06/10/2024
Filed — Alteration CO
SUBSEQUENT FILING FOR THE INSTALLATION OF NEW PLUMBING FIXTURES THROUGHOUT BUILDING AND DRYWELL IN OPEN SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01042730-S2
06/10/2024
Filed — Alteration CO
SUBSEQUENT FILING FOR THE INSTALLATION OF NEW PLUMBING FIXTURES THROUGHOUT BUILDING AND DRYWELL IN OPEN SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01042730-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAMC PLBG, HTG & CLNG, INC02/04/2025
DOB NOWGeneral ConstructionPermit IssuedCUSTOMBUILT HOMES INC11/19/2024
DOB NOWConstruction FencePermit IssuedR&R CONTRACTING MGMT CORP07/30/2024
1 project · most recent 02/28/2025
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
02/28/2025Permit IssuedCUSTOMBUILT HOMES INCHeating Systems
Heating
Navien NPE-240A 199,900 BTU · Boiler ×1
1 project · most recent 02/28/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/28/2025Permit IssuedAMC PLBG, HTG & CLNG, INCGas, Storm, Water/Sanitary
1 project · most recent 07/29/2024
General Wiring
FiledStatusContractorScope
07/29/2024Permit IssuedVILLAGE ELECTL CONTRS INCGeneral Wiring
1 project · most recent 02/28/2025
Wood
FiledStatusContractorScope
02/28/2025Permit IssuedAMC PLBG, HTG & CLNG, INCWood
1 project · most recent 02/28/2025
Fence
FiledStatusContractorScope
02/28/2025Permit IssuedAMC PLBG, HTG & CLNG, INCFence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/13/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/13/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/13/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
02/21/2025Fire-Resistant Penetrations and JointsAshray Solankispecial
02/21/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationAshray Solankispecial
02/21/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesINDARDEO PARBHUNATHspecial
02/21/2025Energy Code Compliance InspectionsAshray Solankiprogress
02/21/2025HVAC-R and service water heating equipmentAshray Solankienergy_progress
02/21/2025HVAC-R and service water piping design and insulationAshray Solankienergy_progress
02/21/2025HVAC-R and service water heating system controlsAshray Solankienergy_progress
02/21/2025Maintenance informationAshray Solankienergy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/22/2026Q01042730-P1Request digital key ↗
08/22/2026Q01042730-S2Request digital key ↗
08/22/2026Q01042730-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01042730-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/22/2026Q01042730-P1Open ↗
08/22/2026Q01042730-S2Open ↗
08/22/2026Q01042730-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01042730-P1Open ↗
08/23/2026Q01042730-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q01042730-P1Open ↗
08/23/2026Q01042730-P1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01042730-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026Q01042730-P1Open ↗
08/22/2026Q01042730-S1Open ↗
08/15/2026Q01042730-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01042730-I1Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01042730-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01042730-I1Open ↗