← Back
Two stories - detached, small or mid-size
90-29 180 STREET
QUEENS · BIN 4211711
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R4-1Zoning
1,622 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,470 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Cellar2p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/30/2022$835K—Private party → Private party$515/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARCALHEK201/03/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A&A BUILDING CONSULTANTS INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DESIGN PROCURE BUILD LLCGeneral Contractor107/08/2026
GLENNS PLUMBING SVCS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010201/03/2024
Building Lifecycle
All (29)Filed (2)Permit Issued (2)Signed Off (2)Violation (4)Inspection (5)Objection (14)
09/30/2024
Signed off — Alteration
Cap and remove shower, residential sink and gas stove in cellar. Propose slop sink and floor drain. Legalize 2 pc bathroom
Q00980080-S1
09/30/2024
Signed off — Alteration
Cap and remove shower, residential sink and gas stove in cellar. Propose slop sink and floor drain. Legalize 2 pc bathroom
Q00980080-I1
07/01/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/27/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/27/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/27/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/19/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/13/2024
Permit issued — General Construction
Q00980080-I1-GC
02/13/2024
Permit issued — Plumbing
Q00980080-S1-PL
01/23/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/16/2024
Objection resolved — Addressed
01/16/2024
Objection resolved — Addressed
01/16/2024
Objection resolved — Addressed
01/12/2024
Objection raised — Scope
01/12/2024
Objection raised — Inspections
01/12/2024
Objection raised — Mechanical
01/12/2024
Objection raised — Scope
01/12/2024
Objection resolved — Addressed
01/12/2024
Objection resolved — Addressed
01/11/2024
Objection raised — Inspections
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Scope
01/03/2024
Filed — Alteration
Cap and remove shower, residential sink and gas stove in cellar. Propose slop sink and floor drain. Legalize 2 pc bathroom
Q00980080-S1
01/03/2024
Filed — Alteration
Cap and remove shower, residential sink and gas stove in cellar. Propose slop sink and floor drain. Legalize 2 pc bathroom
Q00980080-I1
11/14/2023
Violation issued (ECB, closed)
Unknown
11/14/2023
Violation issued (ECB, closed)
Construction
11/14/2023
Violation issued (ECB, closed)
Construction
01/26/2012
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDESIGN PROCURE BUILD02/13/2024
DOB NOWPlumbingSigned-offGLENNS PLUMBING SVCS INC02/13/2024
1 project · most recent 06/04/2024
General Wiring
FiledStatusContractorScope
06/04/2024CompleteKENNETH FISK ELECTRIC CORGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/01/2024Pass-Final General Construction Non-Directive 14PassView ↗
06/27/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/27/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/27/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/19/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026Q00980080-S1Request digital key ↗
08/23/2026Q00980080-I1Request digital key ↗