← Back
Two stories - detached, small or mid-size
90-44 205 STREET
QUEENS · Hollis · BIN 4223102
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,440 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,342 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
Electrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/13/2022$718K—— → —$499/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC107/26/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor107/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036107/26/2026
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
07/29/2026
Permit issued — Solar
Q01435082-I1-SL
07/26/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01435082-I1
07/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
07/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
KAMRUL AHSAN
07/22/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
07/22/2026
Special inspection requirement — Final
Ayracon Almaraz
07/22/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedTRINITY SOLAR LLC07/29/2026
1 project · most recent 09/26/2026
FiledStatusContractorScope
09/26/2026Permit IssuedREDLINE ELECTRIC INC1 meters, 1 new_meters
1 project · most recent 07/26/2026
FiledStatusContractorScope
07/26/2026Permit IssuedTRINITY SOLAR LLC16 panels, 6.56 kw, 676 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/22/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
07/22/2026Structural Stability – Alterations of existing buildingsKAMRUL AHSANspecial
07/22/2026Energy Code Compliance InspectionsAyracon Almarazprogress
07/22/2026FinalAyracon Almarazprogress
07/22/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01435082-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01435082-I1Open ↗
08/25/2026Q01435082-I1Open ↗
08/25/2026Q01435082-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01435082-I1Open ↗
08/25/2026Q01435082-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026Q01435082-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01435082-I1Open ↗