← Back
Two family frame
90-49 53 AVENUE
QUEENS · BIN 4045828
💬 Discuss this project
1930Year Built
2.75Stories
B2Building Class
R5Zoning
2,658 sfGross Floor Area
2Units
1 Open Violation ▸
Two family frame · 3,003 sf lot · 0.89 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction1p · 2 filings · 8 docs
Sub-BasementUnder Construction2p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEVEN KUO ARCHITECT PLLC301/12/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TURNKEY 88 CONTRACTING INGeneral Contractor104/09/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STEVEN KUO4979201/07/2026
Building Lifecycle
All (43)Filed (3)Permit Issued (2)Violation (5)Inspection (2)Objection (29)Special Inspection (2)
08/25/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
07/31/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/11/2026
Permit issued — Plumbing
Q01345193-I1-PL
04/22/2026
Objection resolved — Resolved
04/22/2026
Objection resolved — Resolved
04/22/2026
Objection resolved — Resolved
04/22/2026
Objection resolved — Resolved
04/18/2026
Objection raised — Scope
04/18/2026
Objection raised — Cost
04/18/2026
Objection raised — Scope
04/18/2026
Objection raised — Other
02/22/2026
Objection raised — Fire_Protection
02/22/2026
Objection raised — Code
02/22/2026
Objection raised — Fire_Protection
02/22/2026
Objection raised — Code
02/22/2026
Objection raised — Code
02/22/2026
Objection raised — Energy
02/22/2026
Objection raised — Scope
02/22/2026
Objection raised — Structural
02/22/2026
Objection raised — Admin
02/22/2026
Objection raised — Inspections
02/22/2026
Objection raised — Zoning
02/22/2026
Objection raised — Admin
02/22/2026
Objection raised — Scope
02/18/2026
Permit issued — General Construction
Q01337957-I1-GC
01/23/2026
Objection raised — Admin
01/23/2026
Objection resolved — Addressed
01/12/2026
Filed — Alteration
Q01345193-I1
01/12/2026
Objection resolved — Addressed
01/07/2026
Filed — Alteration CO
filing to install new shower and kitchen sink and cook top at attic convert into (Ancillary Dwelling Unit) ADU within existing building envelope obtain new CO no change in egress, use or occupancy
Q01343040-I1
01/07/2026
Objection resolved — Addressed
01/07/2026
Objection resolved — Addressed
12/30/2025
Objection raised — Zoning
12/29/2025
Objection raised — Plumbing
12/29/2025
Objection raised — Scope
12/19/2025
Filed — Alteration
Q01337957-I1
12/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
STEVEN KUO
12/19/2025
Special inspection requirement — Final
STEVEN KUO
07/08/2025
Violation issued (ECB, closed)
Unknown
07/08/2025
Violation issued (ECB, closed)
Construction
07/08/2025
Violation issued (ECB, open)
Construction
05/27/2020
Violation issued (ECB, closed)
Construction
12/10/2014
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTRI STATE PLBG & HTG INC05/11/2026
DOB NOWGeneral ConstructionPermit IssuedTURNKEY 88 CONTRACTING IN02/18/2026
BISPLISSUEDS & L PLUMBING INC10/15/2004
BISOTISSUEDN/A07/09/2004
1 project · most recent 01/12/2026
Water/Sanitary
FiledStatusContractorScope
01/12/2026Permit IssuedDW PLUMBING INCWater/Sanitary
1 project · most recent 12/19/2025
General Wiring
FiledStatusContractorScope
12/19/2025Permit IssuedA ELECTRICAL MAIN SVC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/25/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
07/31/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/19/2025Structural Stability – Alterations of existing buildingsSTEVEN KUOspecial
12/19/2025FinalSTEVEN KUOprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/18/2026Q01337957-I1Request digital key ↗
08/17/2026Q01343040-I1Request digital key ↗
08/17/2026Q01345193-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026Q01337957-I1Open ↗
08/17/2026Q01343040-I1Open ↗
08/13/2026Q01345193-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/07/2015401947499Open ↗
01/07/2015401947499Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026Q01337957-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026Q01337957-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/18/2026Q01337957-I1Open ↗
08/17/2026Q01343040-I1Open ↗
08/13/2026Q01345193-I1Open ↗