← Back
Primarily 2 family with 1 store or office
9023 3 AVENUE
BROOKLYN · Bay Ridge · BIN 3154544
💬 Discuss this project
1911Year Built
2Stories
S2Building Class
R6BZoning
2,520 sfGross Floor Area
3Units
Rent Stabilized6 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 9023 BROOKLYN LLC · 2,020 sf lot · 1.25 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof3p · 1 filing · 3 docs
Floor 2Under Construction14p · 4 filings · 20 docs
Floor 1Under Construction15p · 3 filings · 18 docs
Cellar8p · 1 filing · 10 docs
Basement1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MADISON CONSTRUCTION CONSULTANTS2408/28/2026
9023 BROOKLYN LLC203/22/2026
9023 THIRD AVE203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/16/2019$1.6M—Private party → 9023 BROOKLYN LLC$635/sf building
03/08/2017$350K—— → —$139/sf building
03/07/2017$50K—— → —$20/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
E.D. PONS ASSOCIATES, P.C.208/26/2026
DANIEL O'CONNOR ARCHITECTS404/20/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SEAY-YARBROUGH603/21/2026
PEROTTO CONSULTING MANAGEMENT203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MADISON CONSTRUCTION CONSGeneral Contractor1007/08/2026
JNR PLUMBING INC DBAPlumbing207/08/2026
RAM, TAGERAMElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DANIEL O'CONNOR ARCHITECT1730203/24/2023
Building Lifecycle
All (85)Filed (6)Permit Issued (9)Violation (31)Objection (25)Special Inspection (14)
08/26/2026
Filed — Alteration
structural work on cellar, 1st, 2nd , roof FILED IN CONJUNCTION WITH JOB#S B00466410 AND B00836778
B01359992-S1
08/05/2026
Special inspection requirement — Final
08/05/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
08/05/2026
Special inspection requirement — Footing and Foundation
05/26/2026
Objection raised — Structural
05/26/2026
Objection raised — Admin
05/26/2026
Objection raised — Admin
05/26/2026
Objection raised — Admin
05/26/2026
Objection raised — Zoning
05/26/2026
Objection raised — Admin
05/26/2026
Objection raised — Scope
05/26/2026
Objection raised — Structural
05/26/2026
Objection raised — Structural
05/07/2026
Filed — Alteration
structural work on cellar, 1st, 2nd , roof FILED IN CONJUNCTION WITH JOB#S B00466410 AND B00836778
B01359992-I1
01/21/2026
Permit issued — General Construction
B00836778-I1-GC
01/21/2026
Permit issued — General Construction
B00466410-I1-GC
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/05/2025
Permit issued — General Construction
B00836778-I1-GC
09/05/2025
Permit issued — General Construction
B00466410-I1-GC
05/28/2025
Violation issued (ECB, open)
Boilers
12/27/2024
Permit issued — Plumbing
B00493709-I1-PL
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/15/2024
Permit issued — General Construction
B00466410-I1-GC
12/20/2023
Permit issued — Plumbing
B00493709-I1-PL
11/28/2023
Violation issued (HPD, closed)
I
07/14/2023
Permit issued — General Construction
B00836778-I1-GC
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/03/2023
Special inspection requirement — HVAC-R and service water heating equipment
Daniel O'Connor
05/03/2023
Special inspection requirement — Energy Code Compliance Inspections
Daniel O'Connor
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/20/2023
Filed — Alteration
B00493709-P1
04/18/2023
Special inspection requirement — Energy Code Compliance Inspections
Daniel O'Connor
04/18/2023
Special inspection requirement — HVAC-R and service water heating equipment
Daniel O'Connor
04/11/2023
Permit issued — General Construction
B00466410-I1-GC
03/24/2023
Filed — Alteration
B00836778-I1
03/01/2023
Special inspection requirement — Final
Harry Hong
03/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel O'Connor
03/16/2022
Violation issued (HPD, closed)
I
12/16/2021
Filed — Alteration
B00493709-I1
08/02/2021
Objection raised — Other
08/02/2021
Objection resolved — Addressed
04/21/2021
Violation issued (HPD, closed)
I
03/29/2021
Objection raised — Other
03/29/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/26/2021
Objection raised — Other
03/26/2021
Objection resolved — Addressed
03/24/2021
Filed — Alteration
#8331 - Interior renovation of existing apartments including GC work. No change in egress, use or occupancy.
B00466410-I1
03/24/2021
Special inspection requirement — Interior lighting power
Daniel O'Connor
03/05/2021
Special inspection requirement — Energy Code Compliance Inspections
Daniel O'Connor
Latest 60 of 85 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS01/21/2026
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS01/21/2026
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS09/05/2025
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS09/05/2025
DOB NOWPlumbingPermit IssuedJNR PLUMBING INC DBA12/27/2024
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS04/15/2024
DOB NOWPlumbingPermit IssuedJNR PLUMBING INC DBA12/20/2023
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS07/14/2023
DOB NOWGeneral ConstructionPermit IssuedMADISON CONSTRUCTION CONS04/11/2023
BISFPISSUEDACTIVE FIRE EXTINGUISHER CO INC07/02/2004
BISPLISSUEDDURNEY MECHANICAL04/27/1993
BISFPISSUEDARROW MECH SYST./IDEAL FIRE03/24/1993
BISPLISSUEDDURNEY MECHANICAL01/26/1993
BIS—ISSUED9023 THIRD AVE12/18/1992
1 project · most recent 02/03/2020
FiledStatusContractorScope
02/03/2020Permit IssuedMERRICK TECH ELEC CORP5 meters, 5 new_meters
1 project · most recent 08/26/2026
Steel Concrete Masonry
FiledStatusContractorScope
08/26/2026——Steel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
08/05/2026Final—progress
08/05/2026Excavations - Sheeting, Shoring, and Bracing—special
08/05/2026Footing and Foundation—progress
05/03/2023HVAC-R and service water heating equipmentDaniel O'Connorenergy_progress
05/03/2023Energy Code Compliance InspectionsDaniel O'Connorprogress
04/18/2023Energy Code Compliance InspectionsDaniel O'Connorprogress
04/18/2023HVAC-R and service water heating equipmentDaniel O'Connorenergy_progress
03/01/2023FinalHarry Hongprogress
03/01/2023Fire-Resistant Penetrations and JointsDaniel O'Connorspecial
03/24/2021Interior lighting powerDaniel O'Connorenergy_progress
03/05/2021Energy Code Compliance InspectionsDaniel O'Connorprogress
03/05/2021Fire-Resistance Rated ConstructionDaniel O'Connorprogress
03/05/2021Fire-Resistant Penetrations and JointsDaniel O'Connorspecial
02/05/2021FinalHarry Hongprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch4
08/27/2026B00836778-I1Request digital key ↗
08/27/2026B00493709-P1Request digital key ↗
08/27/2026B00493709-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - General Construction1
09/01/2026B00466410-I1Request digital key ↗
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature9
09/02/2026B00493709-P1Open ↗
09/02/2026B00493709-P1Open ↗
09/01/2026B00836778-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/27/2026B00493709-I1Open ↗
08/27/2026B00493709-P1Open ↗
08/17/2026B01359992-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00836778-I1Open ↗
08/24/2026B00466410-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/27/2026B00493709-I1Open ↗
08/27/2026B00493709-P1Open ↗
08/17/2026B01359992-S1Open ↗
Showing 3 of 6 on file for this type