← Back
Unlicensed parking lot
903 EAST 140 STREET
BRONX · Mott Haven-Port Morris · BIN 2004049
💬 Discuss this project
0Year Built
—Stories
G7Building Class
M3-1Zoning
0 sfGross Floor Area
0Units
0 Open Violations
Unlicensed parking lot · Owner of record: SILVERCUP STUDIOS NY, LLC · 11,250 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Filed — no permit issued39p · 4 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
S2 CONSTRUCTION803/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EP ENGINEERING LLC202/17/2021
MCNAMARA SALVIA102/11/2021
SHALAT ARCHITECTS P.C.101/08/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OUTSOURCE CONSULTANTS, INC.803/21/2026
Building Lifecycle
All (49)Filed (4)Violation (4)Objection (30)Special Inspection (11)
05/05/2021
Special inspection requirement — Energy Code Compliance Inspections
05/05/2021
Special inspection requirement — Electrical motors
02/25/2021
Objection raised — Admin
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Scope
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Fire_Protection
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Energy
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Energy Recovery Ventilation
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Structural
02/25/2021
Objection resolved — Addressed
02/25/2021
Objection raised — Energy
02/25/2021
Objection resolved — Addressed
02/17/2021
Filed — Alteration
X00358858-I1
02/12/2021
Filed — Alteration
HEREWITH FILING MECHANICAL WORK IN CONJUNCTION WITH NEW BUILDING JOB #21018150
X00358847-I1
02/11/2021
Filed — Alteration
X00358870-I1
02/11/2021
Special inspection requirement — HVAC insulation and sealing
02/11/2021
Special inspection requirement — HVAC and service water heating equipment
02/11/2021
Special inspection requirement — Maintenance information
02/11/2021
Special inspection requirement — HVAC and service water heating system controls
02/11/2021
Special inspection requirement — Shutoff dampers
02/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/10/2021
Special inspection requirement — Post-installed Anchors
01/14/2021
Objection raised — Scope
01/14/2021
Objection resolved — Addressed
01/14/2021
Objection raised — Scope
01/14/2021
Objection resolved — Addressed
01/14/2021
Objection raised — Scope
01/14/2021
Objection resolved — Addressed
01/13/2021
Objection raised — Scope
01/13/2021
Objection resolved — Addressed
01/13/2021
Objection raised — Scope
01/13/2021
Objection resolved — Addressed
01/13/2021
Objection raised — Scope
01/13/2021
Objection resolved — Addressed
01/13/2021
Objection raised — Inspections
01/13/2021
Objection resolved — Addressed
01/13/2021
Objection raised — Scope
01/13/2021
Objection resolved — Addressed
01/08/2021
Filed — Alteration
CURB CUT APPLICATION FILE HEREIN IN SONJUCTION WITH BPP APPLICATION #:240292045 AND NEW BUILDING APPLICATION #:210181505
X00439031-I1
06/16/2020
Special inspection requirement — Mechanical Systems
06/16/2020
Special inspection requirement — Final
03/12/2002
Violation issued (ECB, closed)
Site Safety
03/03/1993
Violation issued (ECB, closed)
Construction
05/20/1992
Violation issued (ECB, closed)
Construction
12/01/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDPREMIER SOLAR SOLUTIONS L04/05/2022
BISCCISSUEDS2 CONSTRUCTION LLC06/16/2016
BIS—ISSUEDJ.E. ACTIVITIES INC03/27/2002
BISEQISSUEDA. RUSSO WRECKING INC02/21/2002
BIS—ISSUEDA. RUSSO WRECKING INC02/21/2002
BISEQISSUEDA. RUSSO WRECKING INC02/21/2002
BIS—ISSUEDA. RUSSO WRECKING INC02/21/2002
BIS—ISSUEDAMEC CONSTRUCTION MANAGEMENT02/21/2001
1 project · most recent 02/12/2021
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/12/2021——Air Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric PUZ-A24NHA7 24,000 BTU · Vrf Indoor ×1
PUZ-A36NKA7 36,000 BTU · Vrf Indoor ×1
TUHYP0964AN40AN 96,000 BTU · Vrf Outdoor ×1
TUMYP0361AK42NA 36,000 BTU · Vrf Outdoor ×1
Trane YCH360 366,000 BTU · Rooftop Unit ×2
YSH300 288,000 BTU · Rooftop Unit ×1
Ventilation
Greenheck USF-6 1 CFM · Exhaust Fan ×1
USF-8 600 CFM · Exhaust Fan ×1
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
05/05/2021Energy Code Compliance Inspections—progress
05/05/2021Electrical motors—energy_progress
02/11/2021HVAC insulation and sealing —energy_progress
02/11/2021HVAC and service water heating equipment —energy_progress
02/11/2021Maintenance information—energy_progress
02/11/2021HVAC and service water heating system controls —energy_progress
02/11/2021Shutoff dampers—energy_progress
02/10/2021Fire-Resistant Penetrations and Joints—special
02/10/2021Post-installed Anchors—special
06/16/2020Mechanical Systems—special
06/16/2020Final—progress
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Structural1
08/25/2026X00358870-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/25/2026X00358858-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/15/2026X00358847-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Curb Cut1
08/14/2026X00439031-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
03/02/2021240292045Open ↗
10/30/2020240292045Open ↗
10/23/2020240290939Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
04/05/2022240290939Open ↗
06/16/2016220521273Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISFLOOD ZONE DESIGN CERTIFICATION1
10/23/2020240290939Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026X00358870-I1Open ↗
08/25/2026X00358858-I1Open ↗
08/13/2026X00358847-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
07/22/2016220521273Open ↗
07/22/2016220521273Open ↗
06/13/2016220521273Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
10/30/2020240292045Open ↗
10/23/2020240290939Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/13/2016220521273Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/16/2016220521273Open ↗
▸Safety & Tenant Protection2
▸BISTPP1: TENANT PROTECTION PLAN1
04/05/2022240290939Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
10/23/2020240290939Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
04/05/2022240290939Open ↗
10/23/2020240290939Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/13/2016220521273Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/23/2020240290939Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
04/05/2022240290939Open ↗
10/23/2020240290939Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
08/15/2016220521273Open ↗
07/22/2016220521273Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/16/2016220521273Open ↗
06/16/2016220521273Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
10/23/2020240290939Open ↗
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION5
03/21/2022240290939Open ↗
03/21/2022240290939Open ↗
11/29/2021240290939Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
10/30/2020240292045Open ↗
10/23/2020240290939Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
10/30/2020240292045Open ↗
▸BISEFILING COVER SHEET1
06/13/2016220521273Open ↗