Two family brick · 2,209 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofSolar panel installation on residential building roof19p · 2 filings · 20 docs
Floor 2Interior renovation and roof bulkhead addition12p · 2 filings · 20 docs
Floor 1Unit 1B112p · 2 filings · 20 docs
CellarInterior renovation and roof bulkhead addition12p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BH26 Holdings2207/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/09/2024$1.9M—909 WILLOUGHBY LLC → Private party$778/sf building
03/15/2022$997K—Private party → 909 WILLOUGHBY LLC$398/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Tom Petersen Architect110/03/2025
Banji Awosika Architect1106/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Banji Architect2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Yafe MeodGeneral Contractor303/21/2026
Solar Contractingspecialty_contractor303/21/2026
Plumbing-It MechanicalPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Thomas Petersen Architect7854110/03/2025
Banji Awosika Architect P27211106/25/2024
Building Lifecycle
04/27/2026
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01296700-I1
11/18/2025
Permit issued — Solar
B01296700-I1-SL
10/20/2025
Objection resolved — Addressed
10/08/2025
Objection raised — Inspections
10/03/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01296700-I1
63 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSolar Contracting11/18/2025
DOB NOWGeneral ConstructionPermit IssuedYafe Meod02/12/2024
DOB NOWPlumbingSigned-offJVR Plumbing and Heating06/14/2023
1 project · most recent 06/25/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScope
06/25/2024Permit IssuedYafe MeodHeating and Air Conditioning Systems, Ventilation Systems
2 projects · most recent 10/01/2025
General Wiring
FiledStatusContractorScope
10/01/2025CompleteVillage Electl Contractors—
04/18/2023CompleteAccurate ElectricalGeneral Wiring
1 project · most recent 06/25/2024
Wood
FiledStatusContractorScope
06/25/2024Permit IssuedYafe MeodWood
1 project · most recent 10/03/2025
FiledStatusContractorScope
10/03/2025Signed-offSolar Contracting—
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
06/05/2024Pass-Final CND-Occupancy InspectionPassView ↗
05/23/2024Fail-Final CND-Occupancy InspectionFailView ↗
04/08/2024Pass-Final CND-Occupancy InspectionPassView ↗
02/29/2024Fail-Final CND-Occupancy InspectionFailView ↗
11/28/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/27/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/29/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
10/02/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
10/02/2025FinalTOM PETERSENprogress
10/02/2025Energy Code Compliance InspectionsTOM PETERSENprogress
10/02/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
10/02/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
07/01/2024Fire-Resistance Rated ConstructionOLABANJI AWOSIKAprogress
07/01/2024FinalOLABANJI AWOSIKAprogress
07/01/2024Lighting controlsOLABANJI AWOSIKAenergy_progress
07/01/2024Lighting in dwelling unitsOLABANJI AWOSIKAenergy_progress
07/01/2024Interior lighting powerOLABANJI AWOSIKAenergy_progress
07/01/2024Fenestration air leakageOLABANJI AWOSIKAenergy_progress
07/01/2024HVAC-R and service water heating system controlsOLABANJI AWOSIKAenergy_progress
07/01/2024Air barrier - visual inspectionOLABANJI AWOSIKAenergy_progress
07/01/2024Shutoff dampersOLABANJI AWOSIKAenergy_progress
07/01/2024Fire-Resistant Penetrations and JointsOLABANJI AWOSIKAspecial
07/01/2024Permanent certificateOLABANJI AWOSIKAenergy_progress
07/01/2024HVAC-R and service water piping design and insulationOLABANJI AWOSIKAenergy_progress
07/01/2024HVAC-R and service water heating equipmentOLABANJI AWOSIKAenergy_progress
07/01/2024MeteringOLABANJI AWOSIKAenergy_progress
07/01/2024Insulation placement and R valuesOLABANJI AWOSIKAenergy_progress
07/01/2024Maintenance informationOLABANJI AWOSIKAenergy_progress
07/01/2024Ventilation and air distribution systemOLABANJI AWOSIKAenergy_progress
07/01/2024Fenestration and door U-factor and product ratingsOLABANJI AWOSIKAenergy_progress
07/01/2024Fenestration areasOLABANJI AWOSIKAenergy_progress
07/01/2024MasonryOLABANJI AWOSIKAspecial