← Back
Two family frame
91-15 183 STREET
QUEENS · BIN 4211887
💬 Discuss this project
1910Year Built
2Stories
B2Building Class
R4-1Zoning
1,980 sfGross Floor Area
2Units
Two family frame · 1,911 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Permit Issued — active, not yet Signed-off
Floor 2Under Construction14p · 1 filing · 20 docs
Floor 1Under Construction13p · 1 filing · 20 docs
CellarUnder Construction15p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/08/2020$864K—— → —$436/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MUMTAZ ENTERPRISES507/09/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SHEIKH EXPEDITING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREAT AMERICAN CONSTR SERGeneral Contractor207/08/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MUMTAZ ENTERPRISES9459507/09/2026
Building Lifecycle
All (15)Filed (5)Permit Issued (3)Special Inspection (7)
07/09/2026
Filed — Alteration
APPLICATION FILE TO REMOVE & REPLACE PLUMBING FIXTURES AS 3PCS BATHROOM, RES. SINK AND INSTALL 2PCS BATHROOM AT 1st & 2nd FLOOR, REMOVE & REPLACE 02PCS BATHROOM AT CELLAR AND INSTALL SHOWER AT CELLAR FLOOR DAMAGED BY FIRE. NO CHANGE IN USE, EGRESS OR OC
Q01255038-P3
07/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mumtaz Hussain
07/05/2026
Filed — Alteration
APPLICATION FILE TO REMOVE & REPLACE PLUMBING FIXTURES AS 3PCS BATHROOM, RES. SINK AND INSTALL 2PCS BATHROOM AT 1st & 2nd FLOOR, REMOVE & REPLACE 02PCS BATHROOM AT CELLAR AND INSTALL SHOWER AT CELLAR FLOOR DAMAGED BY FIRE. NO CHANGE IN USE, EGRESS OR OC
Q01255038-P2
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mumtaz Hussain
06/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mumtaz Hussain
06/22/2026
Special inspection requirement — Final
Mumtaz Hussain
12/02/2025
Permit issued — General Construction
Q01255038-I1-GC
10/14/2025
Filed — Alteration
APPLICATION FILE TO REMOVE & REPLACE PLUMBING FIXTURES AS 3PCS BATHROOM, RES. SINK AND INSTALL 2PCS BATHROOM AT 1st & 2nd FLOOR, REMOVE & REPLACE 02PCS BATHROOM AT CELLAR AND INSTALL SHOWER AT CELLAR FLOOR DAMAGED BY FIRE. NO CHANGE IN USE, EGRESS OR OC
Q01255038-P1
10/10/2025
Special inspection requirement — Final
Mumtaz Hussain
10/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mumtaz Hussain
10/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mumtaz Hussain
09/10/2025
Permit issued — Plumbing
Q01255038-S1-PL
08/07/2025
Permit issued — General Construction
Q01255038-I1-GC
08/04/2025
Filed — Alteration
APPLICATION FILE TO REMOVE & REPLACE PLUMBING FIXTURES AS 3PCS BATHROOM, RES. SINK AND INSTALL 2PCS BATHROOM AT 1st & 2nd FLOOR, REMOVE & REPLACE 02PCS BATHROOM AT CELLAR AND INSTALL SHOWER AT CELLAR FLOOR DAMAGED BY FIRE. NO CHANGE IN USE, EGRESS OR OC
Q01255038-I1
08/04/2025
Filed — Alteration
APPLICATION FILE TO REMOVE & REPLACE PLUMBING FIXTURES AS 3PCS BATHROOM, RES. SINK AND INSTALL 2PCS BATHROOM AT 1st & 2nd FLOOR, REMOVE & REPLACE 02PCS BATHROOM AT CELLAR AND INSTALL SHOWER AT CELLAR FLOOR DAMAGED BY FIRE. NO CHANGE IN USE, EGRESS OR OC
Q01255038-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedGREAT AMERICAN CONSTR SER12/02/2025
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC09/10/2025
DOB NOWGeneral ConstructionPermit IssuedGREAT AMERICAN CONSTR SER08/07/2025
1 project · most recent 07/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/09/2026Permit IssuedALL PRO PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 08/22/2025
General Wiring
FiledStatusContractorScope
08/22/2025Permit IssuedCLAIRMONT ELEC'L CONTR'GGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
07/09/2026Fire-Resistant Penetrations and JointsMumtaz Hussainspecial
06/22/2026Fire-Resistant Penetrations and JointsMumtaz Hussainspecial
06/22/2026Structural Stability – Alterations of existing buildingsMumtaz Hussainspecial
06/22/2026FinalMumtaz Hussainprogress
10/10/2025FinalMumtaz Hussainprogress
10/10/2025Fire-Resistant Penetrations and JointsMumtaz Hussainspecial
10/10/2025Structural Stability – Alterations of existing buildingsMumtaz Hussainspecial
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/18/2026Q01255038-P1Request digital key ↗
08/18/2026Q01255038-S1Request digital key ↗
08/18/2026Q01255038-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWRestrictive Declaration/Easement 15
08/18/2026Q01255038-P2Open ↗
08/18/2026Q01255038-P3Open ↗
08/13/2026Q01255038-P1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/18/2026Q01255038-P3Open ↗
08/18/2026Q01255038-P2Open ↗
08/13/2026Q01255038-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/14/2026Q01255038-P2Open ↗
09/14/2026Q01255038-P2Open ↗
09/01/2026Q01255038-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/14/2026Q01255038-P2Open ↗
08/22/2026Q01255038-P1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/18/2026Q01255038-P2Open ↗
08/18/2026Q01255038-P3Open ↗
08/13/2026Q01255038-P1Open ↗
Showing 3 of 5 on file for this type