← Back
Two family brick
912 EAST 227 STREET
BRONX · Williamsbridge-Olinville · BIN 2064494
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R4Zoning
1,976 sfGross Floor Area
2Units
9 Open Violations 8 unresolved · 1 paperwork only ▸
Two family brick · 2,393 sf lot · 0.83 FAR built · Flood zone X
Locations of Work
Electrical
Roof1p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES A CLANCY102/22/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARC DESIGN AND CONSULTING LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYS ESSENTIAL POWER INCGeneral Contractor303/21/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ETRECTE LLC8116102/22/2024
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Signed Off (1)Violation (13)Special Inspection (5)
06/17/2024
Signed off — Alteration
INSTALLATION OF PV SYSTEM ON EXISITNG ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
X01007696-I1
03/01/2024
Permit issued — Solar
X01007696-I1-SL
02/22/2024
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISITNG ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
X01007696-I1
02/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VYACHESLAV NECHAYEV
02/19/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
VYACHESLAV NECHAYEV
02/19/2024
Special inspection requirement — Energy Code Compliance Inspections
James Clancy
02/19/2024
Special inspection requirement — Final
James Clancy
02/19/2024
Special inspection requirement — Air barrier - visual inspection
James Clancy
09/16/2020
Violation issued (ECB, open)
Construction
07/20/2020
Violation issued (HPD, closed)
C
07/11/2020
Violation issued (HPD, closed)
C
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/11/2020
Violation issued (HPD, open)
B
07/09/2020
Violation issued (HPD, open)
I
07/09/2020
Violation issued (HPD, closed)
C
07/07/2020
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYS ESSENTIAL POWER INC03/01/2024
2 projects · most recent 02/18/2024
FiledStatusContractorScope
02/18/2024CompleteBERGER QUALITY ELEC'L CON—
12/05/2023CompleteBERGER QUALITY ELEC'L CON2 meters
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
02/19/2024Fire-Resistant Penetrations and JointsVYACHESLAV NECHAYEVspecial
02/19/2024Structural Stability – Alterations of existing buildingsVYACHESLAV NECHAYEVspecial
02/19/2024Energy Code Compliance InspectionsJames Clancyprogress
02/19/2024FinalJames Clancyprogress
02/19/2024Air barrier - visual inspectionJames Clancyenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026X01007696-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature3
08/31/2026X01007696-I1Open ↗
08/31/2026X01007696-I1Open ↗
08/31/2026X01007696-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026X01007696-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026X01007696-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026X01007696-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01007696-I1Open ↗