1930Year Built
2Stories
C0Building Class
R6Zoning
2,680 sfGross Floor Area
3Units
Rent Stabilized14 Open Violations ▸FDNY Report ↗
Three families · Owner of record: DDL INTERNATIONAL LLC · 2,579 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Floor 26p · 2 filings · 19 docs
Floor 19p · 2 filings · 19 docs
Cellar7p · 2 filings · 19 docs
Site & exterior4p · 2 filings · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DDL INTERNATIONAL LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/09/2024$1.2M—Private party → DDL INTERNATIONAL LLC$448/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT305/31/2024
J&R DESIGN AND INSPECTION CORP.101/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor507/08/2026
E D ELECTRICAL INCElectrical103/22/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802205/31/2024
NKM ENGINEERING PLLC6244101/16/2024
Building Lifecycle
All (42)Filed (4)Permit Issued (4)Signed Off (3)Violation (16)Inspection (5)Special Inspection (10)
05/01/2026
Violation issued (HPD, open)
A
11/19/2025
Violation issued (HPD, open)
I
06/06/2025
Violation issued (HPD, open)
A
11/27/2024
Violation issued (HPD, open)
I
06/17/2024
Signed off — Alteration
FILE PLUMBING WORK AS PER PLAN, THIS JOB CONJUNCTION WITH DOB GC APPLICATION B00990179-I1, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00990394-I1
06/11/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/10/2024
Signed off — Alteration
B00990179-I1
05/31/2024
Filed — Alteration
FILE PLUMBING WORK AS PER PLAN, THIS JOB CONJUNCTION WITH DOB GC APPLICATION B00990179-I1, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00990394-P1
05/31/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Chun Feng
05/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
05/31/2024
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
05/31/2024
Special inspection requirement — HVAC-R and service water heating equipment
Chun Feng
05/31/2024
Special inspection requirement — HVAC-R and service water heating system controls
Chun Feng
05/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
05/30/2024
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
05/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
Chun Feng
05/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
Chun Feng
05/30/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Chun Feng
04/30/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/30/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/15/2024
Signed off — Alteration
INSTALLING TEMPORARY FENCE OF COMMERCIAL SPACE IN THE REAR YARD, THIS APPLICATION IS IN CONJUNCTION WITH JOB APPLICATION GC/MS#B00990179-I1. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00990178-I1
04/08/2024
Violation issued (HPD, open)
A
01/18/2024
Permit issued — Mechanical Systems
B00990179-I1-GC
01/18/2024
Permit issued — General Construction
B00990179-I1-MS
01/18/2024
Permit issued — Plumbing
B00990394-I1-PL
01/17/2024
Filed — Alteration
FILE PLUMBING WORK AS PER PLAN, THIS JOB CONJUNCTION WITH DOB GC APPLICATION B00990179-I1, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00990394-I1
01/17/2024
Permit issued — Construction Fence
B00990178-I1-FN
01/16/2024
Filed — Alteration
B00990179-I1
01/16/2024
Filed — Alteration
INSTALLING TEMPORARY FENCE OF COMMERCIAL SPACE IN THE REAR YARD, THIS APPLICATION IS IN CONJUNCTION WITH JOB APPLICATION GC/MS#B00990179-I1. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00990178-I1
11/21/2023
Violation issued (HPD, open)
I
03/20/2023
Violation issued (HPD, open)
A
11/09/2022
Violation issued (HPD, open)
I
02/22/2022
Violation issued (HPD, open)
I
02/22/2022
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, open)
I
10/28/2019
Violation issued (HPD, open)
I
10/12/2018
Violation issued (HPD, open)
I
10/06/2015
Violation issued (HPD, closed)
I
02/06/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offHIGH QUALITY CONSTRUCTION01/18/2024
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION01/18/2024
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.01/18/2024
DOB NOWConstruction FenceSigned-offHIGH QUALITY CONSTRUCTION01/17/2024
1 project · most recent 07/20/2024
General Wiring
FiledStatusContractorScope
07/20/2024CompleteE D ELECTRICAL INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/11/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/30/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/30/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/30/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/30/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/31/2024HVAC-R and service water piping design and insulationChun Fengenergy_progress
05/31/2024Fire-Resistant Penetrations and JointsChun Fengspecial
05/31/2024Energy Code Compliance InspectionsChun Fengprogress
05/31/2024HVAC-R and service water heating equipmentChun Fengenergy_progress
05/31/2024HVAC-R and service water heating system controlsChun Fengenergy_progress
05/30/2024Fire-Resistant Penetrations and JointsChun Fengspecial
05/30/2024Energy Code Compliance InspectionsChun Fengprogress
05/30/2024HVAC-R and service water heating equipmentChun Fengenergy_progress
05/30/2024HVAC-R and service water heating system controlsChun Fengenergy_progress
05/30/2024HVAC-R and service water piping design and insulationChun Fengenergy_progress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026B00990179-I1Request digital key ↗
08/26/2026B00990178-I1Request digital key ↗
08/26/2026B00990394-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature8
08/29/2026B00990394-I1Open ↗
08/29/2026B00990394-I1Open ↗
08/29/2026B00990394-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026B00990179-I1Open ↗
08/26/2026B00990178-I1Open ↗
08/13/2026B00990394-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026B00990394-I1Open ↗
08/25/2026B00990394-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026B00990179-I1Open ↗
08/13/2026B00990394-I1Open ↗
08/13/2026B00990394-P1Open ↗