← Back
One family attached or semi-detached
917 HART STREET
BROOKLYN · Bushwick (West) · BIN 3073267
💬 Discuss this project
1984Year Built
2Stories
A5Building Class
R6Zoning
1,452 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
One family attached or semi-detached · Owner of record: 917 HART ACQUISITION LLC · 2,200 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneralOther
Permit Issued — active, not yet Signed-off
RoofUnder Construction131p · 2 filings · 20 docs
Floor 4Under Construction98p · 1 filing · 20 docs
Floor 3Under Construction100p · 1 filing · 20 docs
Floor 2Under Construction97p · 1 filing · 20 docs
Floor 1Under Construction93p · 1 filing · 20 docs
CellarUnder Construction102p · 1 filing · 20 docs
Site & exteriorUnder Construction83p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BELL CONTRACTING NY 11704/09/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/26/2023$1.2M—Private party → 917 HART ACQUISITION LLC$826/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BELL CONTRACTING NY 11203/21/2026
MODERN BUILDING CONSULTANT103/21/2026
FISCHER + MAKOOI ARCHITECTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BELL CONTRACTING NY 1 INCGeneral Contractor1607/08/2026
VILLAGE P & H NY INCFire Protection207/08/2026
ZONE PLUMBING & HEATING CPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S70101007/28/2026
XC ENGINEERING PC9405311/17/2025
GRANT ENGINEERING2627312/23/2024
Building Lifecycle
All (160)Filed (23)Permit Issued (17)Signed Off (10)Violation (11)Inspection (3)Objection (66)Special Inspection (30)
08/13/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED TO INSTALL A NEW SPRINKLER SYSTEM TO A SEVEN (7) FAMILY BUILDING. FILED IN CONJUNCTION WITH ALT 1 JOB B00979960-I1 FOR HORIZONTAL AND VERTICAL ENLARGEMENT.
B00979960-S2
08/11/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/07/2026
Special inspection requirement — Sprinkler Systems
XIUCHENG LI
08/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
08/04/2026
Objection resolved — Addressed
08/04/2026
Objection resolved — Open
08/04/2026
Objection resolved — Addressed
08/04/2026
Objection resolved — Addressed
08/04/2026
Objection resolved — Addressed
08/04/2026
Objection resolved — Addressed
08/04/2026
Objection resolved — Addressed
07/30/2026
Objection raised — Other
07/30/2026
Objection raised — Zoning
07/30/2026
Objection raised — Other
07/30/2026
Objection raised — Other
07/30/2026
Objection raised — Other
07/30/2026
Objection raised — Other
07/30/2026
Objection raised — Other
07/28/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED TO INSTALL A NEW SPRINKLER SYSTEM TO A SEVEN (7) FAMILY BUILDING. FILED IN CONJUNCTION WITH ALT 1 JOB B00979960-I1 FOR HORIZONTAL AND VERTICAL ENLARGEMENT.
B00979960-P6
07/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
07/28/2026
Special inspection requirement — Sprinkler Systems
XIUCHENG LI
07/14/2026
Objection resolved — Addressed
06/25/2026
Signed off — Alteration
Temporary construction fence filed in conjunction with DOB NOW #B00979960-I1 as per plan.
B01150406-I1
06/04/2026
Objection raised — Scope
05/07/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED TO INSTALL A NEW SPRINKLER SYSTEM TO A SEVEN (7) FAMILY BUILDING. FILED IN CONJUNCTION WITH ALT 1 JOB B00979960-I1 FOR HORIZONTAL AND VERTICAL ENLARGEMENT.
B00979960-P5
05/07/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
05/07/2026
Special inspection requirement — Exterior lighting power
XIUCHENG LI
05/07/2026
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
05/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
05/07/2026
Special inspection requirement — Lighting controls
XIUCHENG LI
05/07/2026
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
05/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
05/07/2026
Special inspection requirement — Protection of exposed foundation insulation
XIUCHENG LI
05/07/2026
Special inspection requirement — Permanent certificate
XIUCHENG LI
05/07/2026
Special inspection requirement — Lighting in dwelling units
XIUCHENG LI
05/07/2026
Special inspection requirement — Post-installed Anchors
XIUCHENG LI
05/07/2026
Special inspection requirement — Air barrier — testing
XIUCHENG LI
05/07/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
05/07/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
05/07/2026
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
05/07/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
XIUCHENG LI
05/07/2026
Special inspection requirement — Sprayed fire-resistant materials
XIUCHENG LI
05/07/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/07/2026
Special inspection requirement — Fenestration areas
XIUCHENG LI
05/07/2026
Special inspection requirement — Seismic Isolation Systems
XIUCHENG LI
05/01/2026
Permit issued — Sprinklers
B00979960-S4-EW-SP
04/20/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED TO INSTALL A NEW SPRINKLER SYSTEM TO A SEVEN (7) FAMILY BUILDING. FILED IN CONJUNCTION WITH ALT 1 JOB B00979960-I1 FOR HORIZONTAL AND VERTICAL ENLARGEMENT.
B00979960-Z2
03/19/2026
Signed off — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B01228146-S2
03/18/2026
Signed off — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B01228146-S1
03/18/2026
Signed off — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B01228146-I1
03/17/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED TO INSTALL A NEW SPRINKLER SYSTEM TO A SEVEN (7) FAMILY BUILDING. FILED IN CONJUNCTION WITH ALT 1 JOB B00979960-I1 FOR HORIZONTAL AND VERTICAL ENLARGEMENT.
B00979960-S9
03/17/2026
Permit issued — Support of Excavation
B00979960-Z2-SE
03/10/2026
Permit issued — Mechanical Systems
B00979960-S2-MS
03/04/2026
Permit issued — Construction Fence
B01150406-I1-FN
02/24/2026
Permit issued — Plumbing
B00979960-S3-PL
01/17/2026
Violation issued (ECB, closed)
Construction
01/16/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
01/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2025
Permit issued — General Construction
B00979960-I1-GC
Latest 60 of 160 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC05/01/2026
DOB NOWSupport of ExcavationSigned-offBELL CONTRACTING NY 103/17/2026
DOB NOWMechanical SystemsSigned-offBELL CONTRACTING NY 103/10/2026
DOB NOWConstruction FenceSigned-offBELL CONTRACTING NY 103/04/2026
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C02/24/2026
DOB NOWGeneral ConstructionPermit IssuedBELL CONTRACTING NY 112/01/2025
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC11/05/2025
DOB NOWGeneral ConstructionSigned-offBELL CONTRACTING NY 111/03/2025
DOB NOWSupported ScaffoldSigned-offBELL CONTRACTING NY 106/12/2025
DOB NOWSidewalk ShedSigned-offBELL CONTRACTING NY 106/12/2025
DOB NOWStructuralSigned-offBELL CONTRACTING NY 106/10/2025
DOB NOWFoundationSigned-offBELL CONTRACTING NY 102/10/2025
DOB NOWSupport of ExcavationSigned-offBELL CONTRACTING NY 101/03/2025
DOB NOWStructuralSigned-offBELL CONTRACTING NY 101/02/2025
DOB NOWGeneral ConstructionPermit IssuedBELL CONTRACTING NY 112/27/2024
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C12/13/2024
DOB NOWConstruction FenceSigned-offBELL CONTRACTING NY 112/05/2024
1 project · most recent 07/28/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/28/2026Signed-offBELL CONTRACTING NY 1 INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric SEZ-AD18NL 18,000 BTU · Ahu ×6
SUZAA18NLHZ 2 tons · Heat Pump Outdoor ×6
MLZ-KX06NL 12,000 BTU · Ahu ×1
MSZ-GX09NL 7,000 BTU · Fan Coil Indoor ×1
MXZ-SM36NLHZ 3 tons · Heat Pump Outdoor ×1
SEZ-AD09NL 12,000 BTU · Vrf Indoor ×1
1 project · most recent 07/28/2026
Sprinkler System
FiledStatusContractorScope
07/28/2026Signed-offPARAMOUNT SERVICES, LLCSprinkler System
1 project · most recent 07/28/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/28/2026Signed-offZONE PLUMBING & HEATING CStorm, Water/Sanitary
3 projects · most recent 09/04/2026
General Wiring
FiledStatusContractorScope
09/04/2026Permit IssuedP.L. ELEC'L CONTR'G CORPGeneral Wiring
07/29/2026CompleteP.L. ELEC'L CONTR'G CORPGeneral Wiring
07/01/2025CompleteRICHARD NEU—
1 project · most recent 07/28/2026
Steel Concrete
FiledStatusContractorScope
07/28/2026Signed-offPARAMOUNT SERVICES, LLCSteel, Concrete
1 project · most recent 12/04/2024
Fence
FiledStatusContractorScope
12/04/2024Signed-offBELL CONTRACTING NY 1 INCFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/11/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/16/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 114
DateRequirementInspectorRole
08/07/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
08/07/2026Sprinkler SystemsXIUCHENG LIspecial
07/28/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
07/28/2026Sprinkler SystemsXIUCHENG LIspecial
05/07/2026Fenestration areasXIUCHENG LIenergy_progress
05/07/2026Lighting in dwelling unitsXIUCHENG LIenergy_progress
05/07/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
05/07/2026Air barrier - visual inspectionXIUCHENG LIenergy_progress
05/07/2026Exterior lighting powerXIUCHENG LIenergy_progress
05/07/2026Fenestration air leakageXIUCHENG LIenergy_progress
05/07/2026Sprayed fire-resistant materialsXIUCHENG LIspecial
05/07/2026Interior lighting powerXIUCHENG LIenergy_progress
05/07/2026Maintenance informationXIUCHENG LIenergy_progress
05/07/2026Lighting controlsXIUCHENG LIenergy_progress
05/07/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
05/07/2026Permanent certificateXIUCHENG LIenergy_progress
05/07/2026Protection of exposed foundation insulationXIUCHENG LIenergy_progress
05/07/2026Seismic Isolation SystemsXIUCHENG LIspecial
05/07/2026Post-installed AnchorsXIUCHENG LIspecial
05/07/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/07/2026Construction Operations Influencing Adjacent StructuresXIUCHENG LIspecial
05/07/2026Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
05/07/2026Air barrier — testing XIUCHENG LIenergy_progress
05/07/2026Insulation placement and R valuesXIUCHENG LIenergy_progress
05/07/2026Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
Latest 25 of 114.
▾Documents — 164 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch24
08/23/2026B01150406-I1Request digital key ↗
08/21/2026B01228146-I1Request digital key ↗
08/21/2026B01228146-S1Request digital key ↗
Showing 3 of 24 on file for this type
▸Applications & Permits3
▸BISBPP-5 - Authorization to the Department of Transportation2
10/01/2025340912212Open ↗
10/01/2025340912212Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
07/31/2024340912212Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram3
08/15/2026B00979960-P5Open ↗
08/13/2026B00979960-I1Open ↗
08/13/2026B00979960-P3Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/15/2026B00979960-P5Open ↗
08/13/2026B00979960-I1Open ↗
08/13/2026B00979960-P3Open ↗
▸Seals & Professional Certifications90
▸DOB NOWSpecial Inspector Seal & Signature38
09/19/2026B00979960-S4Open ↗
09/19/2026B00979960-S4Open ↗
09/13/2026B00979960-S9Open ↗
Showing 3 of 38 on file for this type
▸DOB NOWProgress Inspector Seal & Signature28
09/13/2026B00979960-S9Open ↗
09/01/2026B00979960-S5Open ↗
08/31/2026B00979960-S3Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature23
08/23/2026B01150406-I1Open ↗
08/21/2026B01228146-I1Open ↗
08/21/2026B01228146-S1Open ↗
Showing 3 of 23 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/31/2024340912212Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/15/2026B00979960-P5Open ↗
08/13/2026B00979960-I1Open ↗
08/13/2026B00979960-P3Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST2
10/01/2025340912212Open ↗
10/01/2025340912212Open ↗
▸BISSTREET TREES SITE PLAN1
07/31/2024340912212Open ↗
▸BISBPP: STREET TREES SITE PLAN1
08/26/2025340912212Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00979960-I1Open ↗
▸Environmental & Asbestos16
▸DOB NOWDEP ACP-5: Asbestos Assessment Report16
08/17/2026B00979960-Z2Open ↗
08/17/2026B00979960-P4Open ↗
08/17/2026B00979960-P6Open ↗
Showing 3 of 16 on file for this type
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00979960-S6Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B00979960-S6Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
07/31/2024340912212Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial3
08/15/2026B00979960-P5Open ↗
08/13/2026B00979960-P3Open ↗
08/13/2026B00979960-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/15/2026B00979960-P5Open ↗
08/13/2026B00979960-P3Open ↗
08/13/2026B00979960-I1Open ↗
▸DOB NOWProperty Ownership Certification3
08/17/2026B00979960-I1Open ↗
08/15/2026B00979960-P5Open ↗
08/14/2026B00979960-P3Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00979960-Z2Open ↗
08/13/2026B00979960-S7Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
08/26/2025340912212Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
10/01/2025340912212Open ↗
▸DOB NOWFinal Survey1
08/17/2026B00979960-I1Open ↗