← Back
Police Department
92-20 DE SOTA ROAD
QUEENS · Rockaway Beach-Arverne-Edgemere · BIN 4445329
💬 Discuss this project
1929Year Built
3Stories
Y2Building Class
R6AZoning
32,670 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Police Department · Owner of record: NYC POLICE DEPARTMENT · 27,299 sf lot · 1.2 FAR built · Flood zone AE
Locations of Work
Mechanical
Floor 31p · 1 filing · 4 docs
Floor 21p · 1 filing · 4 docs
Floor 12p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
POLICE DEPARTMENT 1103/22/2026
NYPD403/22/2026
DEPARTMENT OF DESIGN AND CONST703/21/2026
NYC DEPT OF DESIGN & CONST.303/21/2026
NYCDDC1803/21/2026
NYC DEPT GENERAL SERVICES103/21/2026
N Y C DEPT OF GENERAL SERVICES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHANDA ENGINEERING CONSULTANT PC106/23/2022
HERBERT KUNSTADT ASSOCIATES, PC111/18/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HERBERT KUNSTADT ASSOCIATES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RNH ELECTRIC COMPANY INCElectrical203/22/2026
KLEIN WILLIAMElectrical103/21/2026
WILLIAM KLEINElectrical103/21/2026
Building Lifecycle
All (30)Filed (2)Violation (18)Special Inspection (10)
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2023
Violation issued (FDNY_ORDER, closed)
06/23/2022
Filed — Alteration
Q00761424-I1
03/07/2022
Violation issued (ECB, open)
Boilers
11/18/2019
Filed — Alteration
REPLACEMENT OF THE BOILER AND THE HEATING SYSTEM FOR THE BUILDING. THERE WILL BE 2 BOILERS SERVING THE BUILDING. NEW FINTUBE ELEMENTS WILL BE ADDED.
Q00203871-I1
08/01/2019
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
HERBERT KUNSTADT
08/01/2019
Special inspection requirement — Mechanical Systems
08/01/2019
Special inspection requirement — Heating Systems
08/01/2019
Special inspection requirement — Final
HERBERT KUNSTADT
08/01/2019
Special inspection requirement — Lowest Floor Elevation
HERBERT KUNSTADT
08/01/2019
Special inspection requirement — HVAC and service water heating system controls
08/01/2019
Special inspection requirement — HVAC and service water heating equipment
08/01/2019
Special inspection requirement — Permanent certificate
08/01/2019
Special inspection requirement — Maintenance information
08/01/2019
Special inspection requirement — HVAC insulation and sealing
06/30/2015
Violation issued (FDNY_ORDER, closed)
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISFSISSUEDMICHAEL S. KAPLAN04/25/2022
BISOTISSUEDGRYPHON CONSTRUCTION INC12/22/2021
BISOTISSUEDGRYPHON CONSTRUCTION INC12/22/2021
BISMHISSUEDGRYPHON CONSTRUCTION INC12/22/2021
BISFSISSUEDMICHAEL S. KAPLAN03/24/2021
BISOTISSUEDGRYPHON CONSTRUCTION INC03/16/2021
BISMHISSUEDGRYPHON CONSTRUCTION INC03/16/2021
BISOTISSUEDGRYPHON CONSTRUCTION INC03/16/2021
BISOTISSUEDGRYPHON CONSTRUCTION INC03/15/2021
BISOTISSUEDGRYPHON CONSTRUCTION INC06/22/2020
BISOTISSUEDGRYPHON CONSTRUCTION INC06/22/2020
BISMHISSUEDGRYPHON CONSTRUCTION INC06/22/2020
BISOTISSUEDGRYPHON CONSTRUCTION INC10/09/2019
BISOTISSUEDGRYPHON CONSTRUCTION INC10/09/2019
BISMHISSUEDGRYPHON CONSTRUCTION INC10/09/2019
BISPLISSUEDTHE PLUMBING COMPANY, INC.06/01/2005
BISOTISSUEDORBA CONSTRUCTION CORP05/26/2005
BISEQISSUEDORBA CONSTRUCTION CORP05/26/2005
BISOTISSUEDORBA CONSTRUCTION CORP05/16/2005
BISEQISSUEDORBA CONSTRUCTION CORP05/16/2005
BISEQISSUEDLILLY CONSTRUCTION CO. INC.03/31/2005
BISEQISSUEDLILLY CONSTRUCTION CO. INC.03/21/2005
BISEQISSUEDLILLY CONSTRUCTION CO. INC.02/02/2005
BISEQISSUEDLILLY CONSTRUCTION CO. INC.02/02/2005
BISEQISSUEDORBA CONSTRUCTION CORP01/24/2005
BISEQISSUEDLILLY CONSTRUCTION CO. INC.06/29/2004
BISEQISSUEDLILLY CONSTRUCTION CO. INC.06/29/2004
BISOTISSUEDORBA CONSTRUCTION CORP06/22/2004
BISEQISSUEDORBA CONSTRUCTION CORP06/22/2004
BISPLISSUEDQUEENS, THE MECHANICAL CORP05/26/2004
BISPLISSUEDJOHN CANNETTI PLUMBING10/31/2003
BISEQISSUEDSAFWAY SERVICE10/24/2003
BISEQISSUEDSAFEWAY STEEL PRODUCTS INC06/18/2003
BISPLISSUEDTHE PLG CO INC04/11/2003
BISOTISSUEDTHE PLG CO INC04/11/2003
BISOTISSUEDTHE FRANKLIN COMANY CONT*04/25/2002
BISOTISSUEDUNICO SERVICE CORP.03/13/1995
BISOTISSUEDTECHNIQUE CONTRACTING CO02/28/1995
BISPLISSUEDAPH UNIVERSAL PLG AND HEATING09/07/1994
BISOTISSUEDTECHNIQUE CONTRACTING CO08/19/1994
1 project · most recent 11/18/2019
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/18/2019——Heating Systems
Heating
Aerco Benchmark 1500 3,000,000 BTU · Condensing Unit ×2
3 projects · most recent 10/20/2022
General Wiring
FiledStatusContractorScope
10/20/2022CompleteRNH ELECTRIC COMPANY INCGeneral Wiring
11/12/2019CompleteRNH ELECTRIC COMPANY INC—
04/05/2018CompleteLEONE ELECTRIC CO. INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/01/2019Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)HERBERT KUNSTADTspecial
08/01/2019Mechanical Systems—special
08/01/2019Heating Systems—special
08/01/2019FinalHERBERT KUNSTADTprogress
08/01/2019Lowest Floor ElevationHERBERT KUNSTADTprogress
08/01/2019HVAC and service water heating system controls —energy_progress
08/01/2019HVAC and service water heating equipment —energy_progress
08/01/2019Permanent certificate—energy_progress
08/01/2019Maintenance information—energy_progress
08/01/2019HVAC insulation and sealing —energy_progress
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/28/2026Q00203871-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/26/2026Q00761424-I1Request digital key ↗
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION8
07/05/2022421577911Open ↗
04/13/2022421577911Open ↗
11/22/2017421577911Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION4
06/10/2021421577911Open ↗
10/10/2019421577911Open ↗
10/10/2019421577911Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
09/30/2019421577911Open ↗
09/30/2019421577911Open ↗
09/30/2019421577911Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026Q00761424-I1Open ↗
08/13/2026Q00203871-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
11/22/2017421577911Open ↗
01/27/2014420910553Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
09/14/2022421577911Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/22/2017421577911Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026Q00761424-I1Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
09/30/2019421577911Open ↗
11/22/2017421577911Open ↗
11/22/2017421577911Open ↗
Showing 3 of 6 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
09/14/2022421577911Open ↗
▸BIS* HVAC INSULATION AND SEALING1
09/14/2022421577911Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/15/2022421577911Open ↗
▸Inspections & Test Reports6
▸BISMECHANICAL DEMOLITION1
09/14/2022421577911Open ↗
▸BISMASONRY1
09/14/2022421577911Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
09/14/2022421577911Open ↗
▸BISMECHANICAL SYSTEMS1
09/14/2022421577911Open ↗
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
09/14/2022421577911Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
09/14/2022421577911Open ↗
▸Approvals, Objections & Sign-offs11
▸BISDESIGN COMM. SIGNOFF: CITY-OWNED PROPERTY (EXTERIOR WORK)2
03/11/2022421577911Open ↗
03/11/2022421577911Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
11/22/2017421577911Open ↗
01/27/2014420910553Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
09/27/2019421577911Open ↗
03/19/2014420910553Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/26/2026Q00761424-I1Open ↗
08/13/2026Q00203871-I1Open ↗
▸BISFINAL1
09/14/2022421577911Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/24/2025421577911Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026Q00203871-I1Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT6
11/22/2017421577911Open ↗
11/22/2017421577911Open ↗
11/22/2017421577911Open ↗
Showing 3 of 6 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
10/18/2022421577911Open ↗
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET6
11/22/2017421577911Open ↗
11/22/2017421577911Open ↗
11/22/2017421577911Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION1
05/02/2022421577911Open ↗
▸Other Documents3
▸BISFUEL-OIL STORAGE AND FUEL-OIL PIPING SYSTEMS1
09/14/2022421577911Open ↗
▸BISEMERGENCY & STANDBY POWER SYSTEMS (GENERATORS)1
09/14/2022421577911Open ↗
▸BISSHUTOFF DAMPERS1
09/14/2022421577911Open ↗