← Back
Factory, light manufacturing
92 VAN DYKE STREET
BROOKLYN · BIN 3008816
💬 Discuss this project
1931Year Built
2Stories
F5Building Class
M1-1Zoning
10,900 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Factory, light manufacturing · Owner of record: 9 4TH PLACE, LLC · 5,450 sf lot · 2 FAR built · Flood zone AE
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OC CONSTRUCTION GROUP307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEVIN ENGINEERING PLLC106/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEVIN ENGINEERING PLLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EARLY PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEVIN ENGINEERING PLLC1267106/10/2022
Building Lifecycle
All (24)Filed (1)Permit Issued (1)Signed Off (1)Violation (8)Inspection (1)Objection (10)Special Inspection (2)
04/05/2023
Violation issued (FDNY_NOV, closed)
08/30/2022
Signed off — Alteration
INSTALLATION OF NEW GAS FIRED UNIT HEATER. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00723915-I1
08/19/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/09/2022
Permit issued — Plumbing
B00723915-I1-PL
06/29/2022
Objection resolved — Addressed
06/29/2022
Objection resolved — Addressed
06/27/2022
Objection raised — Scope
06/27/2022
Objection raised — Energy
06/17/2022
Objection resolved — Addressed
06/17/2022
Objection resolved — Addressed
06/17/2022
Objection resolved — Addressed
06/17/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Dmitry Levin
06/16/2022
Objection raised — Inspections
06/16/2022
Objection raised — Inspections
06/16/2022
Objection raised — Scope
06/10/2022
Filed — Alteration
INSTALLATION OF NEW GAS FIRED UNIT HEATER. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00723915-I1
04/22/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dmitry Levin
01/11/2021
Violation issued (FDNY_ORDER, closed)
04/16/2019
Violation issued (FDNY_NOV, closed)
04/16/2019
Violation issued (FDNY_NOV, closed)
01/06/2012
Violation issued (FDNY_NOV, closed)
06/08/1994
Violation issued (FDNY_NOV, closed)
12/27/1988
Violation issued (FDNY_NOV, closed)
11/25/1988
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offEARLY PLBG & HTG INC07/09/2022
1 project · most recent 03/25/2022
FiledStatusContractorScope
03/25/2022Permit IssuedM.A.M. ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/19/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
06/17/2022HVAC-R and service water piping design and insulationDmitry Levinenergy_progress
04/22/2022Fire-Resistant Penetrations and JointsDmitry Levinspecial
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B00723915-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/29/2026B00723915-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/26/2026B00723915-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/26/2026B00723915-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026B00723915-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis1
08/15/2026B00723915-I1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/15/2026B00723915-I1Open ↗