← Back
Two family brick
921 60 STREET
BROOKLYN · Sunset Park (East)-Borough Park (West) · BIN 3140927
💬 Discuss this project
1905Year Built
2Stories
B1Building Class
R6Zoning
1,908 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · Owner of record: 921 WU INC · 2,003 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof8p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 16 docs
Floor 611p · 2 filings · 20 docs
Floor 56p · 2 filings · 20 docs
Floor 43p · 1 filing · 20 docs
Floor 34p · 1 filing · 20 docs
Floor 28p · 2 filings · 20 docs
Floor 15p · 2 filings · 20 docs
Cellar7p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAFE-SHIELD ENTERPRISES407/08/2026
LXC CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/20/2022$998K—Private party → 921 WU INC$523/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HTX BUILDING CONSULTING INC1201/20/2026
INDETAIL ARCHITECTURAL AND ENGIN311/18/2024
ASHRAF CORP109/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HTX BUILDING CONSULTING1503/21/2026
DANICO SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LXC CONSTRUCTION INCGeneral Contractor2307/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing307/08/2026
FLINT MECHANICAL CORPFire Protection107/08/2026
HF GROUP PLMBG & SPNKLERFire Protection107/08/2026
SAFE-SHEILD ENTERPRISE INGeneral Contractor107/08/2026
QMB PLUMBING & HEATING INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S70101301/20/2026
Building Lifecycle
All (144)Filed (16)Permit Issued (18)Signed Off (7)Violation (2)Inspection (13)Objection (58)Special Inspection (30)
08/28/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
STRUCTURAL AND FOUNDATION WORKS FOR A PROPOSED 6-STORY MIX USED BUILDING WITH PENTHOUSE
B00754901-S1
07/31/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
STRUCTURAL AND FOUNDATION WORKS FOR A PROPOSED 6-STORY MIX USED BUILDING WITH PENTHOUSE
B00754901-S3
07/24/2026
Signed off — Alteration
File BL WORK TYPE IN CONJUCTION WITH ALT1 JOB# B00754901
B01204186-I1
07/22/2026
Signed off — Alteration
FIle PL permit for SD 1 and 2 inspection , no change in use, egress or occupancy
B01234055-I1
05/07/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/05/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/05/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/21/2026
Permit issued — Plumbing
B00754901-S3-EW-SP
03/31/2026
Signed off — Alteration
B00814563-I1
03/31/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
STRUCTURAL AND FOUNDATION WORKS FOR A PROPOSED 6-STORY MIX USED BUILDING WITH PENTHOUSE
B00754901-S2
02/27/2026
Permit issued — Support of Excavation
B00754901-S2-SE
02/05/2026
Special inspection requirement — Protection of exposed foundation insulation
XIUCHENG LI
02/05/2026
Special inspection requirement — Footing and Foundation
XIUCHENG LI
02/05/2026
Special inspection requirement — Structural Cold-Formed Steel
XIUCHENG LI
02/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
02/05/2026
Special inspection requirement — Masonry
XIUCHENG LI
02/05/2026
Special inspection requirement — Final
XIUCHENG LI
02/05/2026
Special inspection requirement — Concrete - Cast-In-Place
XIUCHENG LI
02/05/2026
Special inspection requirement — Underpinning
XIUCHENG LI
02/05/2026
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
02/05/2026
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
02/05/2026
Special inspection requirement — Structural Steel - Welding
XIUCHENG LI
02/05/2026
Special inspection requirement — Structural Steel - Details
XIUCHENG LI
02/05/2026
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
02/05/2026
Special inspection requirement — Fenestration areas
XIUCHENG LI
02/05/2026
Special inspection requirement — Structural Steel - High Strength Bolting
XIUCHENG LI
02/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
02/05/2026
Special inspection requirement — Subgrade Inspections
XIUCHENG LI
02/05/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
XIUCHENG LI
01/28/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
XIUCHENG LI
01/28/2026
Special inspection requirement — Heating Systems
XIUCHENG LI
01/28/2026
Special inspection requirement — Shutoff dampers
XIUCHENG LI
01/28/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
01/28/2026
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
01/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
01/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
01/28/2026
Special inspection requirement — Protection of exposed foundation insulation
XIUCHENG LI
01/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
01/28/2026
Special inspection requirement — Exterior lighting power
XIUCHENG LI
01/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
01/28/2026
Special inspection requirement — Lighting in dwelling units
XIUCHENG LI
01/22/2026
Objection resolved — Addressed
01/21/2026
Objection resolved — Addressed
01/20/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
STRUCTURAL AND FOUNDATION WORKS FOR A PROPOSED 6-STORY MIX USED BUILDING WITH PENTHOUSE
B00754901-P7
11/17/2025
Objection raised — Other
10/16/2025
Objection raised — Other
09/24/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
STRUCTURAL AND FOUNDATION WORKS FOR A PROPOSED 6-STORY MIX USED BUILDING WITH PENTHOUSE
B00754901-P6
09/15/2025
Filed — Alteration
File BL WORK TYPE IN CONJUCTION WITH ALT1 JOB# B00754901
B01204186-P1
09/10/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
08/29/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/27/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/01/2025
Permit issued — Plumbing
B00754901-S3-EW-SP
06/16/2025
Violation issued (ECB, closed)
Construction
06/09/2025
Inspection — Pass-Final House Connection
Pass
View inspection ↗
06/04/2025
Permit issued — Plumbing
B01234055-I1-PL
06/02/2025
Filed — Alteration
FIle PL permit for SD 1 and 2 inspection , no change in use, egress or occupancy
B01234055-I1
05/29/2025
Permit issued — Boiler Equipment
B01204186-I1-BE
05/28/2025
Signed off — Alteration
HEAVYDUTY SIDEWALK SHED IN ORDER TO DO A VERTICAL EXTENSION AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE.
B01107625-I1
Latest 60 of 144 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHF GROUP PLMBG & SPNKLER04/21/2026
DOB NOWSupport of ExcavationSigned-offLXC CONSTRUCTION INC02/27/2026
DOB NOWPlumbingSigned-offBLETSAS P&H CORP08/01/2025
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC06/04/2025
DOB NOWBoiler EquipmentSigned-offAMC PLBG, HTG & CLNG, INC05/29/2025
DOB NOWEarth WorkSigned-offLXC CONSTRUCTION INC05/20/2025
DOB NOWGeneral ConstructionPermit IssuedLXC CONSTRUCTION INC05/19/2025
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC05/06/2025
DOB NOWConstruction FenceSigned-offLXC CONSTRUCTION INC10/04/2024
DOB NOWSidewalk ShedSigned-offSAFE-SHEILD ENTERPRISE IN09/09/2024
DOB NOWMechanical SystemsPermit IssuedLXC CONSTRUCTION INC05/21/2024
DOB NOWFoundationSigned-offLXC CONSTRUCTION INC05/21/2024
DOB NOWSupport of ExcavationSigned-offLXC CONSTRUCTION INC05/15/2024
DOB NOWFoundationSigned-offLXC CONSTRUCTION INC03/01/2024
DOB NOWSprinklersSigned-offAMC PLBG, HTG & CLNG, INC01/04/2024
DOB NOWConstruction FenceSigned-offLXC CONSTRUCTION INC10/06/2023
DOB NOWGeneral ConstructionPermit IssuedLXC CONSTRUCTION INC10/05/2023
DOB NOWSupport of ExcavationSigned-offLXC CONSTRUCTION INC10/05/2023
1 project · most recent 01/20/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/20/2026Signed-offLXC CONSTRUCTION INCHeating and Air Conditioning Systems
Heat / Cool
Fujitsu AOU24RLXFZ 2 tons · Condensing Unit ×18
Gree 4LIV24HP230V1A0 (COOLING @22000 BTU , HEATING @24000 BTU) 22,000 BTU · Condensing Unit ×4
2 projects · most recent 01/20/2026
Storm Gas Water/Sanitary
FiledStatusContractorScope
01/20/2026Signed-offAMC PLBG, HTG & CLNG, INCGas, Storm, Water/Sanitary
06/02/2025Signed-offNYC MAINMAN CORPStorm
2 projects · most recent 01/06/2026
FiledStatusContractorScope
01/06/2026CompleteGOODALL ELECTRIC CORP12 meters, 12 new_meters
02/12/2025CompleteKJK ELECTRIC INC—
1 project · most recent 01/20/2026
Steel Concrete Masonry
FiledStatusContractorScope
01/20/2026Signed-offHF GROUP PLMBG & SPNKLERSteel, Concrete, Masonry
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
05/07/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/07/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/05/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/05/2026Pass-Final CND-Occupancy InspectionPassView ↗
09/10/2025Pass-Final Boiler Equipment InspectionPassView ↗
08/29/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/27/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/09/2025Pass-Final House ConnectionPassView ↗
05/02/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/02/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/02/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/02/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 120
DateRequirementInspectorRole
02/05/2026Footing and FoundationXIUCHENG LIprogress
02/05/2026Structural Cold-Formed SteelXIUCHENG LIspecial
02/05/2026UnderpinningXIUCHENG LIspecial
02/05/2026Excavations - Sheeting, Shoring, and BracingXIUCHENG LIspecial
02/05/2026Subgrade InspectionsXIUCHENG LIspecial
02/05/2026Concrete - Cast-In-PlaceXIUCHENG LIspecial
02/05/2026Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
02/05/2026Structural Steel - High Strength BoltingXIUCHENG LIspecial
02/05/2026MasonryXIUCHENG LIspecial
02/05/2026Structural Steel - WeldingXIUCHENG LIspecial
02/05/2026Structural Steel - DetailsXIUCHENG LIspecial
02/05/2026Protection of exposed foundation insulationXIUCHENG LIenergy_progress
02/05/2026Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
02/05/2026Fenestration air leakageXIUCHENG LIenergy_progress
02/05/2026Insulation placement and R valuesXIUCHENG LIenergy_progress
02/05/2026Fenestration areasXIUCHENG LIenergy_progress
02/05/2026Air barrier - visual inspectionXIUCHENG LIenergy_progress
02/05/2026FinalXIUCHENG LIprogress
01/28/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
01/28/2026FinalXIUCHENG LIprogress
01/28/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
01/28/2026Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
01/28/2026MasonryXIUCHENG LIspecial
01/28/2026Mechanical SystemsXIUCHENG LIspecial
01/28/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
Latest 25 of 120.
▾Documents — 192 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/27/2026B00814563-I1Request digital key ↗
08/27/2026B00754901-S3Request digital key ↗
08/27/2026B00754901-P7Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
02/02/2024340878170Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/02/2024340878170Open ↗
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZoning Exhibit form (1-5)4
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-I1Open ↗
08/15/2026B00754901-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-I1Open ↗
08/15/2026B00754901-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/27/2026B00754901-I1Open ↗
▸Seals & Professional Certifications117
▸DOB NOWProgress Inspector Seal & Signature59
09/23/2026B01204186-I1Open ↗
08/29/2026B00754901-I1Open ↗
08/29/2026B00754901-I1Open ↗
Showing 3 of 59 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature42
09/23/2026B01204186-I1Open ↗
08/29/2026B00754901-I1Open ↗
08/29/2026B00754901-I1Open ↗
Showing 3 of 42 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/27/2026B00814563-I1Open ↗
08/27/2026B00754901-P7Open ↗
08/27/2026B00754901-P6Open ↗
Showing 3 of 14 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/02/2024340878170Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/02/2024340878170Open ↗
▸Trade Schedules & Equipment8
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)8
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-P2Open ↗
08/27/2026B00754901-I1Open ↗
Showing 3 of 8 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
08/27/2026B00754901-I1Open ↗
08/14/2026B00754901-S1Open ↗
▸DOB NOWStreet Tree Sign Off2
08/27/2026B00754901-I1Open ↗
08/14/2026B00754901-S1Open ↗
▸BISBPP: STREET TREES SITE PLAN1
02/02/2024340878170Open ↗
▸DOB NOWStreet Trees Site Plan1
08/27/2026B00754901-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/27/2026B00754901-P7Open ↗
08/27/2026B00754901-P5Open ↗
08/27/2026B00754901-P4Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/27/2026B00754901-I1Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
02/02/2024340878170Open ↗
▸BISADDITIONAL INFORMATION1
02/02/2024340878170Open ↗
▸Other Documents24
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone8
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-P2Open ↗
08/27/2026B00754901-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSite Survey: Initial8
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-P2Open ↗
08/27/2026B00754901-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProperty Ownership Certification4
08/27/2026B00754901-P4Open ↗
08/27/2026B00754901-I1Open ↗
08/15/2026B00754901-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/14/2026B00754901-S1Open ↗
08/13/2026B00754901-S2Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
02/02/2024340878170Open ↗
▸DOB NOWFinal Survey1
08/27/2026B00754901-I1Open ↗