← Back
Two family brick
929 EAST 219 STREET
BRONX · Williamsbridge-Olinville · BIN 2059047
💬 Discuss this project
1935Year Built
2Stories
B1Building Class
R4Zoning
1,620 sfGross Floor Area
2Units
18 Open Violations ▸
Two family brick · 2,383 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar6p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/24/2019$689K—TIGER GATE LLC → Private party$425/sf building
10/13/2017$353K—U.S. BANK NATIONAL ASSOCIATION → TIGER GATE LLC$218/sf building
09/12/2017$495K—— → —$306/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GINO O. LONGO, ARCHITECT506/09/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JAMES BERNARDOElectrical203/21/2026
ROBERT CHIMENTIElectrical103/21/2026
ROBERT CHIMENTIElectrical103/22/2026
A GUAMAN CONSTRUCTION CORGeneral Contractor104/09/2026
RENEW PLUMBING CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GINO O. LONGO ARCHITETCT331506/09/2026
Building Lifecycle
All (47)Filed (5)Permit Issued (2)Signed Off (2)Violation (20)Inspection (5)Objection (8)Special Inspection (5)
08/26/2026
Signed off — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-I1
08/11/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/22/2026
Signed off — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-S2
06/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
06/09/2026
Filed — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-P3
06/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
04/28/2026
Filed — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-P2
04/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
04/15/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/12/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/20/2026
Filed — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-P1
03/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
03/03/2026
Permit issued — Plumbing
X01217527-S2-PL
12/05/2025
Permit issued — General Construction
X01217527-I1-GC
09/18/2025
Filed — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-S2
09/03/2025
Objection raised — Cost
09/03/2025
Objection resolved — Addressed
08/25/2025
Objection resolved — Addressed
08/14/2025
Objection resolved — Addressed
08/14/2025
Objection resolved — Addressed
07/10/2025
Objection raised — Other
07/10/2025
Objection raised — Other
07/10/2025
Objection raised — Other
07/03/2025
Filed — Alteration
APPLICATION HEREWITH FILED FOR LEGALIZING RENOVATIONS AT CELLAR AND TO CURE ECB VIOLATIONS 39138350P, 39138335R, 35482589Y, AND & DOB VIOLATIONS V 072523C23-02141; V 072523C23-02140. NO CHANGE TO OCCUPANCY USE, EGRESS, OR BULK
X01217527-I1
06/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
02/13/2025
Violation issued (ECB, closed)
Unknown
02/13/2025
Violation issued (ECB, closed)
Construction
06/09/2024
Violation issued (HPD, open)
B
06/09/2024
Violation issued (HPD, open)
B
06/09/2024
Violation issued (HPD, open)
B
06/09/2024
Violation issued (HPD, open)
B
06/09/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
06/06/2024
Violation issued (HPD, open)
B
07/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/02/2023
Violation issued (HPD, open)
I
05/14/2023
Violation issued (HPD, open)
B
05/14/2023
Violation issued (HPD, open)
B
05/14/2023
Violation issued (HPD, open)
B
05/14/2023
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRENEW PLUMBING CORP03/03/2026
DOB NOWGeneral ConstructionSigned-offA GUAMAN CONSTRUCTION COR12/05/2025
BISOTISSUEDFLORENTON RIVER LLC09/09/2019
1 project · most recent 06/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/09/2026Signed-offRENEW PLUMBING CORPGas, Water/Sanitary
2 projects · most recent 12/16/2019
FiledStatusContractorScope
12/16/2019Permit IssuedROBERT CHIMENTI3 meters, 1 new_meters
11/18/2019CompleteCANDELA SYSTEMS CORP DBA—
1 project · most recent 06/09/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
06/09/2026Signed-offRENEW PLUMBING CORPTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/11/2026Pass-Final General Construction Non-Directive 14PassView ↗
04/15/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/12/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/25/2026Fire-Resistant Penetrations and JointsGINO LONGOspecial
06/05/2026Fire-Resistant Penetrations and JointsGINO LONGOspecial
04/24/2026Fire-Resistant Penetrations and JointsGINO LONGOspecial
03/11/2026Fire-Resistant Penetrations and JointsGINO LONGOspecial
05/09/2025Fire-Resistant Penetrations and JointsGINO LONGOspecial
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/17/2026X01217527-P3Request digital key ↗
08/17/2026X01217527-P2Request digital key ↗
08/17/2026X01217527-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
09/09/2019240259849Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
08/09/2019240259849Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026X01217527-I1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026X01217527-P2Open ↗
08/17/2026X01217527-P1Open ↗
08/17/2026X01217527-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/02/2026X01217527-P3Open ↗
08/27/2026X01217527-I1Open ↗
08/26/2026X01217527-P1Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/09/2019240259849Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
08/09/2019240259849Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/17/2026X01217527-P2Open ↗
08/17/2026X01217527-P3Open ↗
08/17/2026X01217527-S2Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/09/2019240259849Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
02/11/2020240259849Open ↗
02/04/2020240259849Open ↗
02/04/2020240259849Open ↗
Showing 3 of 4 on file for this type
▸BISSOLAR TAX ABATEMENT APPLICATION3
02/04/2020240259849Open ↗
02/04/2020240259849Open ↗
08/09/2019240259849Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
02/11/2020240259849Open ↗
02/04/2020240259849Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
02/18/2020240259849Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
02/11/2020240259849Open ↗
02/04/2020240259849Open ↗
02/04/2020240259849Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs4
▸BISUtility Company PV System Interconnection Acknowledgement Letter3
02/11/2020240259849Open ↗
02/04/2020240259849Open ↗
02/04/2020240259849Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/18/2020240259849Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
02/18/2020240259849Open ↗
02/04/2020240259849Open ↗
02/04/2020240259849Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
08/09/2019240259849Open ↗
▸Other Documents2
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
02/11/2020240259849Open ↗
02/11/2020240259849Open ↗