← Back
Two stories - detached, small or mid-size
93-13 VANDERVEER STREET
QUEENS · Queens Village · BIN 4226651
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R2Zoning
1,200 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,448 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
Electrical
Roof4p · 1 filing · 12 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/14/2015$382K—— → —$318/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC209/19/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor203/21/2026
SUNRUN SOLAR ELECTL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272209/19/2024
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (5)
12/05/2024
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01100951-I1
09/19/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01100951-P1
09/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
09/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
09/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
09/18/2024
Special inspection requirement — Final
Walid Abdulla
09/18/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
09/05/2024
Permit issued — Solar
Q01100951-I1-SL
08/29/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01100951-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC09/05/2024
BISOTISSUEDN/A10/22/1993
1 project · most recent 09/18/2024
FiledStatusContractorScope
09/18/2024CompleteSUNRUN SOLAR ELECTL CORP—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/18/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
09/18/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
09/18/2024Energy Code Compliance InspectionsWalid Abdullaprogress
09/18/2024FinalWalid Abdullaprogress
09/18/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01100951-I1Request digital key ↗
08/21/2026Q01100951-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q01100951-P1Open ↗
09/01/2026Q01100951-P1Open ↗
09/01/2026Q01100951-P1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01100951-P1Open ↗
08/21/2026Q01100951-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01100951-P1Open ↗
09/01/2026Q01100951-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01100951-P1Open ↗
08/21/2026Q01100951-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01100951-I1Open ↗