← Back
Two family frame
9324 FT HAMILTON PARKWAY
BROOKLYN · BIN 3155379
💬 Discuss this project
1915Year Built
2Stories
B2Building Class
R5BZoning
1,870 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family frame · 2,750 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 5 docs
Floor 1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/01/2016$874K—Private party → Private party$467/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIC 88 CORP112/20/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RUBEN LOPEZElectrical103/21/2026
CUBE BUILDERS GROUP NYGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIC 88 CORP8371112/20/2022
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (8)
02/07/2023
Signed off — Alteration
PROPOSED INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. NEW PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT, WORK AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00801928-I1
12/22/2022
Permit issued — General Construction
B00801928-I1-GC
12/20/2022
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. NEW PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT, WORK AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00801928-I1
12/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
12/20/2022
Special inspection requirement — Final
Eric Sun
12/20/2022
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
12/20/2022
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
12/20/2022
Special inspection requirement — Interior lighting power
Eric Sun
12/20/2022
Special inspection requirement — Air barrier - visual inspection
Eric Sun
12/20/2022
Special inspection requirement — Metering
Eric Sun
12/20/2022
Special inspection requirement — Insulation placement and R values
Eric Sun
02/23/2022
Violation issued (HPD, open)
C
02/06/2022
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offCUBE BUILDERS GROUP NY12/22/2022
BISOTISSUEDDESIGN DEPOT INC12/30/2016
BISPLISSUEDTOP PLUMBING GROUP,INC11/22/2016
BISOTISSUEDDESIGN DEPOT INC10/06/2016
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
12/20/2022Fire-Resistant Penetrations and JointsEric Sunspecial
12/20/2022FinalEric Sunprogress
12/20/2022Energy Code Compliance InspectionsEric Sunprogress
12/20/2022Fire-Resistance Rated ConstructionEric Sunprogress
12/20/2022Interior lighting powerEric Sunenergy_progress
12/20/2022Air barrier - visual inspectionEric Sunenergy_progress
12/20/2022MeteringEric Sunenergy_progress
12/20/2022Insulation placement and R valuesEric Sunenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/28/2026B00801928-I1Request digital key ↗
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION3
12/30/2016321402291Open ↗
11/22/2016321402291Open ↗
10/07/2016321402291Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
01/06/2017321402291Open ↗
10/11/2016321402291Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/05/2017321402291Open ↗
▸Seals & Professional Certifications8
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/14/2017321402291Open ↗
10/11/2016321402291Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026B00801928-I1Open ↗
08/25/2026B00801928-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/11/2016321402291Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/11/2016321402291Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00801928-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B00801928-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
01/06/2017321402291Open ↗
10/11/2016321402291Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
01/05/2017321402291Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
10/11/2016321402291Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/11/2016321402291Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/14/2017321402291Open ↗
10/11/2016321402291Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/14/2017321402291Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS1
10/11/2016321402291Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/14/2017321402291Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/14/2017321402291Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/14/2017321402291Open ↗
10/11/2016321402291Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
10/11/2016321402291Open ↗
▸BISADDITIONAL INFORMATION1
01/06/2017321402291Open ↗