← Back
Old law tenement
935 COLLEGE AVENUE
BRONX · Concourse-Concourse Village · BIN 2002010
💬 Discuss this project
1913Year Built
4Stories
C4Building Class
R7-1Zoning
9,516 sfGross Floor Area
9Units
Rent Stabilized100 Open Violations ▸
Old law tenement · Owner of record: NEV VENTURE INC. · 2,675 sf lot · 3.56 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 44p · 1 filing · 9 docs
Floor 33p · 1 filing · 9 docs
Floor 2
Floor 1
Cellar29p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEV VENTURE INC.203/22/2026
BEECO CONTRACTING103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
OMFPE CONSULTING PLLC305/11/2026
BASSIRI103/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARCHVISION DESIGN STUDIO103/21/2026
CITY CONSULTANT ENGINEERING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LATTY'S GEN PLBG CONT CORPlumbing206/28/2026
WILLIAM GEIGERElectrical103/21/2026
AKHTAR CONSTRUCTION CO INGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ADJ ENGINEERING PLLC7640305/11/2026
BASSIRI8394103/02/2023
Building Lifecycle
All (82)Filed (4)Permit Issued (3)Violation (60)Inspection (3)Objection (2)Special Inspection (10)
08/18/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/10/2026
Inspection — Fail-Final PL - Underground
Fail
View inspection ↗
07/31/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/12/2026
Violation issued (HPD, open)
C
05/19/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dwayne Williams
05/11/2026
Filed — Alteration
INSTALL TWO NEW GAS BOILERS IN EXISTING BOILER ROOM.
X01167728-P1
11/17/2025
Violation issued (HPD, closed)
I
11/11/2025
Violation issued (HPD, open)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, open)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, closed)
B
11/11/2025
Violation issued (HPD, closed)
C
09/18/2025
Permit issued — Boiler Equipment
X01167728-S1-BE
09/04/2025
Permit issued — Plumbing
X01167728-I1-PL
06/04/2025
Violation issued (HPD, closed)
A
05/01/2025
Objection resolved — Addressed
04/28/2025
Objection raised — Cost
04/19/2025
Filed — Alteration
INSTALL TWO NEW GAS BOILERS IN EXISTING BOILER ROOM.
X01167728-S1
04/14/2025
Filed — Alteration
INSTALL TWO NEW GAS BOILERS IN EXISTING BOILER ROOM.
X01167728-I1
02/27/2025
Special inspection requirement — HVAC-R and service water heating system controls
Dwayne Williams
02/27/2025
Special inspection requirement — Maintenance information
Dwayne Williams
02/27/2025
Special inspection requirement — HVAC-R and service water heating equipment
Dwayne Williams
02/27/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Dwayne Williams
02/23/2025
Special inspection requirement — Tenant Protection Plan Compliance
Dwayne Williams
02/17/2025
Special inspection requirement — Heating Systems
Dwayne Williams
11/22/2024
Violation issued (HPD, closed)
I
04/02/2024
Violation issued (HPD, closed)
A
11/16/2023
Violation issued (HPD, closed)
I
04/03/2023
Permit issued — General Construction
X00600534-I1-GC
03/16/2023
Violation issued (HPD, closed)
A
03/02/2023
Filed — Alteration
ALTERATION FILED FOR INSTALLATION HARDWOOD FL, CERAMIC TILES AT KITCHEN & BATHRM. FL, REPLACE KITCHEN CABINET, COSMETIC PAINT, REPLACE EXISTING. INSIDE DOOR 3rd Fl. (Apt # 3N & 3S) 4th Fl.(Apartment 4S & 4N)NO CHANGE IN USE EGRESS OR ANY OCCUPANCY.
X00600534-I1
03/02/2023
Special inspection requirement — Tenant Protection Plan Compliance
FARHAD BASSIRI-TEHRANI
11/03/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
09/25/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
C
05/19/2021
Violation issued (HPD, open)
A
04/02/2021
Violation issued (HPD, closed)
I
04/02/2021
Violation issued (HPD, closed)
A
08/06/2020
Violation issued (HPD, closed)
C
08/06/2020
Violation issued (HPD, closed)
C
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/30/2018
Violation issued (HPD, closed)
B
04/30/2018
Violation issued (HPD, closed)
B
04/30/2018
Violation issued (HPD, closed)
B
04/30/2018
Violation issued (HPD, closed)
B
04/30/2018
Violation issued (HPD, closed)
B
04/30/2018
Violation issued (HPD, closed)
B
11/09/2017
Violation issued (HPD, closed)
I
Latest 60 of 82 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentPermit IssuedLATTY'S GEN PLBG CONT COR09/18/2025
DOB NOWPlumbingPermit IssuedLATTY'S GEN PLBG CONT COR09/04/2025
DOB NOWGeneral ConstructionPermit IssuedAKHTAR CONSTRUCTION CO IN04/03/2023
BISOTISSUEDC.JAMES PLUMBING & HEATING10/26/2011
BISPLISSUEDC JAMES PLBG & HTG INC10/26/2011
1 project · most recent 05/11/2026
Gas
FiledStatusContractorScope
05/11/2026Permit IssuedLATTY'S GEN PLBG CONT CORGas
4 projects · most recent 03/16/2026
General Wiring
FiledStatusContractorScope
03/16/2026Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
11/18/2024CancelledADAM ELECL CONTRNG LLCGeneral Wiring
07/31/2020Permit IssuedF & F ELECTRICAL CORP.General Wiring
03/27/2019Permit IssuedWATTS ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/18/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/10/2026Fail-Final PL - UndergroundFailView ↗
07/31/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/19/2026Tenant Protection Plan Compliance—special
05/19/2026Fire-Resistant Penetrations and JointsDwayne Williamsspecial
02/27/2025HVAC-R and service water heating system controlsDwayne Williamsenergy_progress
02/27/2025Maintenance informationDwayne Williamsenergy_progress
02/27/2025HVAC-R and service water heating equipmentDwayne Williamsenergy_progress
02/27/2025HVAC-R and service water piping design and insulationDwayne Williamsenergy_progress
02/23/2025Tenant Protection Plan ComplianceDwayne Williamsspecial
02/17/2025Heating SystemsDwayne Williamsspecial
03/02/2023Tenant Protection Plan ComplianceFARHAD BASSIRI-TEHRANIspecial
09/25/2021Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
▾Documents — 58 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/23/2026X00600534-P1Request digital key ↗
08/23/2026X00600534-I1Request digital key ↗
08/16/2026X01167728-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION4
10/26/2011220146982Open ↗
10/26/2011220146982Open ↗
10/26/2011220146982Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
10/26/2011220146982Open ↗
10/14/2009220032042Open ↗
▸Seals & Professional Certifications21
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026X01167728-S1Open ↗
09/23/2026X01167728-S1Open ↗
08/31/2026X00600534-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026X00600534-P1Open ↗
08/23/2026X00600534-I1Open ↗
08/16/2026X01167728-P1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
10/26/2011220146982Open ↗
10/26/2011220146982Open ↗
07/21/2010220032042Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026X01167728-S1Open ↗
09/23/2026X01167728-S1Open ↗
09/23/2026X01167728-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/26/2011220146982Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/26/2011220146982Open ↗
▸Trade Schedules & Equipment7
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
05/23/2013220146982Open ↗
10/27/2011220146982Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION2
05/23/2013220146982Open ↗
05/31/2012220146982Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
05/31/2012220146982Open ↗
05/29/2012220146982Open ↗
▸BISSCHEDULE B - PLUMBING1
10/26/2011220146982Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026X00600534-P1Open ↗
08/23/2026X00600534-I1Open ↗
08/16/2026X01167728-P1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
10/26/2011220146982Open ↗
10/14/2009220032042Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
10/26/2011220146982Open ↗
▸Approvals, Objections & Sign-offs4
▸BISADMINISTRATIVE OBJECTIONS2
10/26/2011220146982Open ↗
10/14/2009220032042Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/21/2010220032042Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/21/2010220032042Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/26/2011220146982Open ↗
07/21/2010220032042Open ↗
10/14/2009220032042Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
10/26/2011220146982Open ↗
10/14/2009220032042Open ↗
▸BISADDITIONAL INFORMATION2
03/21/2012220146982Open ↗
02/29/2012220146982Open ↗