← Back
Two family frame
94-15 113 STREET
QUEENS · South Richmond Hill · BIN 4197549
💬 Discuss this project
1901Year Built
2Stories
B2Building Class
R4AZoning
1,948 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · 5,428 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 26p · 2 filings · 20 docs
Floor 18p · 2 filings · 20 docs
Cellar7p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
URENA CONSTRUCTION & DESIGN1303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOTIR ASSOCIATES410/06/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
URENA CONST & DESIGN INCGeneral Contractor303/21/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050210/01/2021
Building Lifecycle
All (20)Filed (4)Permit Issued (2)Signed Off (2)Violation (1)Inspection (4)Special Inspection (7)
11/15/2021
Signed off — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #Q00482306.
Q00487001-I1
10/18/2021
Signed off — Alteration
PROPOSED INTERIOR RENOVATIONS OF EXISTING TWO FAMILY HOUSE TO REPAIR FIRE DAMAGE & REMOVE AND INSTALL NEW PLUMBING FIXTURES. PLUMBING TO BE FILED SEPARATELY. NO CHANGE IN OCCUPANCY, USE, OR EGRESS.
Q00482306-I1
10/15/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/08/2021
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
10/06/2021
Filed — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #Q00482306.
Q00487001-P1
10/01/2021
Filed — Alteration
PROPOSED INTERIOR RENOVATIONS OF EXISTING TWO FAMILY HOUSE TO REPAIR FIRE DAMAGE & REMOVE AND INSTALL NEW PLUMBING FIXTURES. PLUMBING TO BE FILED SEPARATELY. NO CHANGE IN OCCUPANCY, USE, OR EGRESS.
Q00482306-P1
09/30/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
PAUL MARINO
09/30/2021
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
09/30/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
09/30/2021
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
09/30/2021
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
09/30/2021
Special inspection requirement — Final
Hany Demetry
06/18/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/18/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/18/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/15/2021
Permit issued — Plumbing
Q00487001-I1-PL
06/14/2021
Filed — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #Q00482306.
Q00487001-I1
03/16/2021
Permit issued — General Construction
Q00482306-I1-GC
03/12/2021
Filed — Alteration
PROPOSED INTERIOR RENOVATIONS OF EXISTING TWO FAMILY HOUSE TO REPAIR FIRE DAMAGE & REMOVE AND INSTALL NEW PLUMBING FIXTURES. PLUMBING TO BE FILED SEPARATELY. NO CHANGE IN OCCUPANCY, USE, OR EGRESS.
Q00482306-I1
10/25/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR06/15/2021
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC03/16/2021
2 projects · most recent 05/14/2021
General Wiring
FiledStatusContractorScope
05/14/2021Permit IssuedC.FALCO ELETL CONT CORPGeneral Wiring
10/27/2020Permit IssuedALL WAYS ELECTRIC CORP.W—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/15/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/18/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/18/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/18/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/08/2021Energy Code Compliance InspectionsHany Demetryprogress
09/30/2021Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
09/30/2021Energy Code Compliance InspectionsPAUL MARINOprogress
09/30/2021Fire-Resistant Penetrations and JointsPAUL MARINOspecial
09/30/2021Lighting in dwelling unitsPAUL MARINOenergy_progress
09/30/2021Energy Code Compliance InspectionsHany Demetryprogress
09/30/2021FinalHany Demetryprogress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026Q00482306-P1Request digital key ↗
08/27/2026Q00482306-I1Request digital key ↗
08/27/2026Q00487001-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/13/2026Q00487001-I1Open ↗
08/13/2026Q00482306-I1Open ↗
08/13/2026Q00482306-P1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026Q00487001-P1Open ↗
08/26/2026Q00482306-P1Open ↗
08/26/2026Q00482306-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00482306-P1Open ↗
08/27/2026Q00482306-I1Open ↗
08/13/2026Q00487001-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q00482306-P1Open ↗
08/26/2026Q00482306-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026Q00482306-P1Open ↗
08/27/2026Q00482306-I1Open ↗
08/13/2026Q00487001-P1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00482306-I1Open ↗