← Back
Two family brick
94-24 121 STREET
QUEENS · BIN 4199170
💬 Discuss this project
1905Year Built
2Stories
B1Building Class
R5Zoning
2,044 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 2,302 sf lot · 0.89 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/23/2021$950K—— → —$465/sf building
09/29/2014$580K—Private party → Private party$284/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JANHA BUILDING IDEAS108/23/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JANHA BUILDING IDEAS INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LV CONTRACTING SOLUTIONSGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JANHA BUILDING IDEAS INC6129108/23/2024
Building Lifecycle
All (14)Filed (1)Permit Issued (1)Signed Off (1)Violation (4)Special Inspection (7)
01/14/2025
Signed off — Alteration
Window restoration and address violation#39113294Z.
Q01098484-I1
12/19/2024
Permit issued — General Construction
Q01098484-I1-GC
08/23/2024
Filed — Alteration
Window restoration and address violation#39113294Z.
Q01098484-I1
08/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Energy Code Compliance Inspections
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Final
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Fenestration air leakage
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Air barrier - visual inspection
KAMRUZ ZAMAN
08/23/2024
Special inspection requirement — Fenestration areas
KAMRUZ ZAMAN
05/02/2024
Violation issued (ECB, closed)
Construction
05/01/2019
Violation issued (HPD, closed)
B
03/23/2015
Violation issued (ECB, closed)
Construction
03/20/2015
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offLV CONTRACTING SOLUTIONS12/19/2024
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
08/23/2024Fire-Resistant Penetrations and JointsKAMRUZ ZAMANspecial
08/23/2024Energy Code Compliance InspectionsKAMRUZ ZAMANprogress
08/23/2024FinalKAMRUZ ZAMANprogress
08/23/2024Fenestration and door U-factor and product ratingsKAMRUZ ZAMANenergy_progress
08/23/2024Fenestration air leakageKAMRUZ ZAMANenergy_progress
08/23/2024Air barrier - visual inspectionKAMRUZ ZAMANenergy_progress
08/23/2024Fenestration areasKAMRUZ ZAMANenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01098484-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026Q01098484-I1Open ↗
08/28/2026Q01098484-I1Open ↗
08/28/2026Q01098484-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026Q01098484-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01098484-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026Q01098484-I1Open ↗