← Back
Two family converted from one family
94-50 SUTTER AVENUE
QUEENS · BIN 4247893
💬 Discuss this project
1925Year Built
2.5Stories
B3Building Class
R4AZoning
1,944 sfGross Floor Area
2Units
Two family converted from one family · 2,700 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/01/2017$350K—— → —$180/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN D CALCAGNILE ARCHITECT111/23/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SERVE-WELL P&H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495111/23/2020
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Inspection (3)Special Inspection (3)
05/16/2022
Signed off — Alteration
Installation of underground storm drainage piping, area drain , grit chamber and drywell in conjunction with one car detached garage filed under NB # 440630783
Q00430299-I1
07/12/2021
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
07/09/2021
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/09/2021
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/26/2021
Permit issued — Plumbing
Q00430299-I1-PL
05/18/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
05/18/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Rajasekhar Sakhamuri
05/13/2021
Special inspection requirement — Electrical energy consumption
John Calcagnile
11/23/2020
Filed — Alteration
Installation of underground storm drainage piping, area drain , grit chamber and drywell in conjunction with one car detached garage filed under NB # 440630783
Q00430299-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSERVE-WELL P&H INC05/26/2021
BIS—ISSUEDBERTOLINI CONTRACTING INC04/07/2021
BIS—ISSUEDBERTOLINI CONTRACTING INC03/22/2021
BIS—ISSUEDKP CONTRACTING ASSO.,INC05/22/2019
BISPLISSUEDSPARACO'S P&H CORP10/10/2018
BIS—ISSUEDKP CONTRACTING ASSO.,INC07/12/2018
2 projects · most recent 06/23/2021
General Wiring
FiledStatusContractorScope
06/23/2021CompleteTRIANGLE ELECTRIC INC.General Wiring
03/05/2018CompleteTRIANGLE ELECTRIC INC.General Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/12/2021Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/09/2021Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/09/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
05/18/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
05/18/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationRajasekhar Sakhamurispecial
05/13/2021Electrical energy consumptionJohn Calcagnileenergy_progress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00430299-I1Request digital key ↗
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION3
05/30/2019421629189Open ↗
10/12/2018421629189Open ↗
07/20/2018421629189Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
07/14/2020421629189Open ↗
05/08/2018421629189Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
07/17/2020421629189Open ↗
▸Seals & Professional Certifications7
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
08/03/2018421629189Open ↗
07/20/2018421629189Open ↗
05/08/2018421629189Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026Q00430299-I1Open ↗
08/22/2026Q00430299-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00430299-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026Q00430299-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
05/08/2018421629189Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
06/04/2018421629189Open ↗
▸BISTenant Protection Plan and Notes1
06/04/2018421629189Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/04/2018421629189Open ↗
▸Energy Compliance6
▸BISAS-BUILT ENERGY ANALYSIS2
08/27/2020421629189Open ↗
08/25/2020421629189Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/20/2018421629189Open ↗
05/08/2018421629189Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
08/25/2020421629189Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00430299-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/25/2020421629189Open ↗
08/25/2020421629189Open ↗
08/25/2020421629189Open ↗
▸Approvals, Objections & Sign-offs1
▸BISSCHEDULE A - OCCUPANCY / USE1
05/08/2018421629189Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/08/2018421629189Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
05/08/2018421629189Open ↗
▸BISADDITIONAL INFORMATION1
06/04/2018421629189Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
07/23/2018421629189Open ↗