← Back
Two stories - detached, small or mid-size
94-58 221 STREET
QUEENS · Queens Village · BIN 4229844
💬 Discuss this project
1915Year Built
2.5Stories
A1Building Class
R3-2Zoning
2,252 sfGross Floor Area
1Units
19 Open Violations 3 unresolved · 16 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 6,370 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
Architecture
Filed — no permit issued9p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M. BAZAC ARCHITECT206/26/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING203/21/2026
Building Lifecycle
All (54)Filed (2)Violation (21)Objection (23)Special Inspection (8)
07/21/2026
Objection raised — Other
07/21/2026
Objection raised — Other
06/26/2026
Filed — New Building
NEW MIXED USE BUILDING, COMMERCIAL HEALTH AND FITNESS ESTABLISHMENT AND RESIDENTIAL ON A VACANT LOT.
Q01012206-S1
06/26/2026
Objection resolved — Addressed
06/26/2026
Objection resolved — Addressed
07/23/2025
Objection resolved — Addressed
07/02/2025
Special inspection requirement — Concrete - Cast-In-Place
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Open
07/01/2025
Objection resolved — Open
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
07/08/2024
Objection raised — Scope
07/08/2024
Objection raised — Admin
07/08/2024
Objection raised — Other
07/08/2024
Objection raised — Inspections
07/08/2024
Objection raised — Structural
07/08/2024
Objection raised — Inspections
07/08/2024
Objection raised — Fire_Protection
07/08/2024
Objection raised — Structural
07/08/2024
Objection raised — Fire_Protection
07/08/2024
Objection raised — Other
07/08/2024
Objection raised — Energy
07/08/2024
Objection raised — Admin
06/26/2024
Filed — New Building
NEW MIXED USE BUILDING, COMMERCIAL HEALTH AND FITNESS ESTABLISHMENT AND RESIDENTIAL ON A VACANT LOT.
Q01012206-I1
05/30/2024
Special inspection requirement — Insulation placement and R values
05/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
05/30/2024
Special inspection requirement — Fenestration areas
05/30/2024
Special inspection requirement — Fenestration air leakage
05/30/2024
Special inspection requirement — Air barrier - visual inspection
02/28/2024
Special inspection requirement — Footing and Foundation
02/28/2024
Special inspection requirement — Final
12/10/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/08/2015
Violation issued (ECB, open)
Construction
06/20/2015
Violation issued (ECB, open)
Construction
05/20/2015
Violation issued (ECB, open)
Construction
05/01/2015
Violation issued (ECB, open)
Construction
03/10/2015
Violation issued (ECB, open)
Construction
02/14/2015
Violation issued (ECB, open)
Construction
12/19/2014
Violation issued (ECB, open)
Construction
11/10/2014
Violation issued (ECB, open)
Construction
11/10/2014
Violation issued (ECB, open)
Construction
09/09/2014
Violation issued (ECB, open)
Construction
09/09/2014
Violation issued (ECB, open)
Construction
07/24/2014
Violation issued (ECB, open)
Construction
07/24/2014
Violation issued (ECB, open)
Construction
02/27/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/27/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/01/2012
Violation issued (ECB, open)
Construction
12/01/2012
Violation issued (ECB, closed)
Construction
12/01/2012
Violation issued (ECB, open)
Construction
12/01/2012
Violation issued (ECB, open)
Quality of Life
12/01/2012
Violation issued (ECB, closed)
Construction
Nothing on file for this building.
1 project · most recent 06/26/2026
FiledStatusContractorScope
06/26/2026——1 scope_items
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/02/2025Concrete - Cast-In-Place—special
05/30/2024Insulation placement and R values—energy_progress
05/30/2024Fenestration and door U-factor and product ratings—energy_progress
05/30/2024Fenestration areas—energy_progress
05/30/2024Fenestration air leakage—energy_progress
05/30/2024Air barrier - visual inspection—energy_progress
02/28/2024Footing and Foundation—progress
02/28/2024Final—progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/15/2026Q01012206-S1Request digital key ↗
08/14/2026Q01012206-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
02/12/2013420799844Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/14/2026Q01012206-I1Open ↗
08/13/2026Q01012206-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026Q01012206-S1Open ↗
08/13/2026Q01012206-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/12/2013420799844Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
02/12/2013420799844Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/12/2013420799844Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/12/2013420799844Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01012206-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/12/2013420799844Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
02/12/2013420799844Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/12/2013420799844Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q01012206-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01012206-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01012206-I1Open ↗