← Back
Miscellaneous two family
943 EAST 78 STREET
BROOKLYN · Canarsie · BIN 3224801
💬 Discuss this project
1960Year Built
3Stories
B9Building Class
R5BZoning
2,304 sfGross Floor Area
2Units
Miscellaneous two family · 1,800 sf lot · 1.28 FAR built · Flood zone X500
Locations of Work
ArchitectureElectrical
Roof3p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC102/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854102/11/2025
Building Lifecycle
All (19)Filed (1)Permit Issued (1)Signed Off (1)Objection (10)Special Inspection (6)
04/23/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01178562-I1
03/11/2025
Permit issued — Solar
B01178562-I1-SL
02/26/2025
Objection resolved — Addressed
02/26/2025
Objection resolved — Addressed
02/26/2025
Objection resolved — Addressed
02/26/2025
Objection resolved — Addressed
02/26/2025
Objection resolved — Addressed
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Other
02/21/2025
Objection raised — Structural
02/21/2025
Objection raised — Other
02/21/2025
Objection raised — Other
02/11/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01178562-I1
02/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/10/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
02/10/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
02/10/2025
Special inspection requirement — Final
TOM PETERSEN
02/10/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC03/11/2025
2 projects · most recent 03/16/2025
FiledStatusContractorScope
03/16/2025CompleteBERGER QUALITY ELEC'L CON2 meters
02/11/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
02/10/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/10/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/10/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
02/10/2025Energy Code Compliance InspectionsTOM PETERSENprogress
02/10/2025FinalTOM PETERSENprogress
02/10/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B01178562-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
09/26/2026B01178562-I1Open ↗
09/26/2026B01178562-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/26/2026B01178562-I1Open ↗
09/26/2026B01178562-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01178562-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01178562-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01178562-I1Open ↗