← Back
Two family brick
945 77 STREET
BROOKLYN · BIN 3149480
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R4-1Zoning
2,232 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 2,433 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HES CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/22/2022$1.7M—— → —$753/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YE DEVELOPMENT INC.708/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY BUILDING NY ARCHITECT603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HES CONSTRUCTION INCGeneral Contractor307/08/2026
WASOFF PLBG & UTILITY COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JASON ZHEN YU YE3246508/22/2023
Building Lifecycle
All (71)Filed (7)Permit Issued (4)Signed Off (4)Violation (1)Inspection (5)Objection (24)Special Inspection (26)
09/25/2023
Signed off — Alteration
To file MS mechanical work in conjunction with DOB Now Build application job#B08011928. Install new split HVAC unit at cel, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011941-I1
08/28/2023
Special inspection requirement — Mechanical Systems
YU YE ZHEN
08/28/2023
Special inspection requirement — Duct leakage testing, insulation and design
YU YE ZHEN
08/28/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
YU YE ZHEN
08/28/2023
Special inspection requirement — HVAC-R and service water heating system controls
YU YE ZHEN
08/28/2023
Special inspection requirement — HVAC-R and service water heating equipment
YU YE ZHEN
08/28/2023
Special inspection requirement — Final
YU YE ZHEN
08/28/2023
Special inspection requirement — Energy Code Compliance Inspections
YU YE ZHEN
08/22/2023
Filed — Alteration
To file MS mechanical work in conjunction with DOB Now Build application job#B08011928. Install new split HVAC unit at cel, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011941-P1
08/14/2023
Signed off — Alteration
To file structure ST work type to replace existing wood floor joist at cellar, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011928-I1
08/11/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/10/2023
Signed off — Alteration
To file structure ST work type to replace existing wood floor joist at cellar, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011928-S1
07/26/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/31/2023
Signed off — Alteration
To file PL plumbing work in conjunction with dob now build job#B08011928. Remove & cap existing plumbing & gas fixtures at cel, 1st & 2nd fl. Install new plumbing fixtures at cel, 1st & 2nd fl No change in use, egress or occupancy under this application.
B08011935-I1
01/31/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/26/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
YU YE ZHEN
01/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YU YE ZHEN
01/26/2023
Special inspection requirement — Energy Code Compliance Inspections
YU YE ZHEN
01/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
YU YE ZHEN
01/26/2023
Special inspection requirement — Fenestration air leakage
YU YE ZHEN
01/26/2023
Special inspection requirement — Fenestration areas
YU YE ZHEN
01/26/2023
Special inspection requirement — Air barrier - visual inspection
YU YE ZHEN
01/26/2023
Special inspection requirement — Insulation placement and R values
YU YE ZHEN
01/17/2023
Filed — Alteration
To file PL plumbing work in conjunction with dob now build job#B08011928. Remove & cap existing plumbing & gas fixtures at cel, 1st & 2nd fl. Install new plumbing fixtures at cel, 1st & 2nd fl No change in use, egress or occupancy under this application.
B08011935-P2
01/12/2023
Filed — Alteration
To file structure ST work type to replace existing wood floor joist at cellar, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011928-P1
01/06/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/04/2023
Special inspection requirement — Fire-Resistance Rated Construction
YU YE ZHEN
01/04/2023
Special inspection requirement — Air barrier - visual inspection
YU YE ZHEN
01/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YU YE ZHEN
01/04/2023
Special inspection requirement — Energy Code Compliance Inspections
YU YE ZHEN
01/04/2023
Special inspection requirement — Fenestration areas
YU YE ZHEN
01/04/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
YU YE ZHEN
01/04/2023
Special inspection requirement — Insulation placement and R values
YU YE ZHEN
01/04/2023
Special inspection requirement — Fenestration air leakage
YU YE ZHEN
12/02/2022
Permit issued — Structural
B08011928-S1-ST
11/30/2022
Objection raised — Structural
11/30/2022
Objection resolved — Addressed
11/30/2022
Objection raised — Admin
11/30/2022
Objection resolved — Addressed
11/30/2022
Objection raised — Structural
11/30/2022
Objection resolved — Addressed
11/29/2022
Filed — Alteration
To file structure ST work type to replace existing wood floor joist at cellar, 1st and 2nd floor. No change in use, egress or occupancy under this application.
B08011928-S1
11/23/2022
Special inspection requirement — Construction Operations Influencing Adjacent Structures
YU YE ZHEN
11/23/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
YU YE ZHEN
11/23/2022
Special inspection requirement — Final
YU YE ZHEN
11/21/2022
Violation issued (ECB, closed)
Construction
11/01/2022
Permit issued — Plumbing
B08011935-I1-PL
10/26/2022
Permit issued — General Construction
B08011928-I1-GC
10/25/2022
Permit issued — Mechanical Systems
B08011941-I1-MS
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection resolved — Addressed
10/12/2022
Objection raised — Other
10/12/2022
Objection raised — Other
10/12/2022
Objection raised — Other
10/12/2022
Objection raised — Other
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offHES CONSTRUCTION INC12/02/2022
DOB NOWPlumbingSigned-offWASOFF PLBG & UTILITY CO11/01/2022
DOB NOWGeneral ConstructionSigned-offHES CONSTRUCTION INC10/26/2022
DOB NOWMechanical SystemsSigned-offHES CONSTRUCTION INC10/25/2022
1 project · most recent 11/14/2022
General Wiring
FiledStatusContractorScope
11/14/2022CompleteAL-LECTRIC ELECT'L CONTRGGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/11/2023Pass-Final General Construction Non-Directive 14PassView ↗
07/26/2023Fail-Final General Construction Non-Directive 14FailView ↗
01/31/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/06/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/06/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
08/28/2023Mechanical SystemsYU YE ZHENspecial
08/28/2023Duct leakage testing, insulation and designYU YE ZHENenergy_progress
08/28/2023HVAC-R and service water piping design and insulationYU YE ZHENenergy_progress
08/28/2023HVAC-R and service water heating system controlsYU YE ZHENenergy_progress
08/28/2023HVAC-R and service water heating equipmentYU YE ZHENenergy_progress
08/28/2023FinalYU YE ZHENprogress
08/28/2023Energy Code Compliance InspectionsYU YE ZHENprogress
01/26/2023Fenestration and door U-factor and product ratingsYU YE ZHENenergy_progress
01/26/2023Fire-Resistant Penetrations and JointsYU YE ZHENspecial
01/26/2023Energy Code Compliance InspectionsYU YE ZHENprogress
01/26/2023Fire-Resistance Rated ConstructionYU YE ZHENprogress
01/26/2023Fenestration air leakageYU YE ZHENenergy_progress
01/26/2023Fenestration areasYU YE ZHENenergy_progress
01/26/2023Air barrier - visual inspectionYU YE ZHENenergy_progress
01/26/2023Insulation placement and R valuesYU YE ZHENenergy_progress
01/04/2023Fire-Resistance Rated ConstructionYU YE ZHENprogress
01/04/2023Air barrier - visual inspectionYU YE ZHENenergy_progress
01/04/2023Fire-Resistant Penetrations and JointsYU YE ZHENspecial
01/04/2023Energy Code Compliance InspectionsYU YE ZHENprogress
01/04/2023Fenestration areasYU YE ZHENenergy_progress
01/04/2023Fenestration and door U-factor and product ratingsYU YE ZHENenergy_progress
01/04/2023Insulation placement and R valuesYU YE ZHENenergy_progress
01/04/2023Fenestration air leakageYU YE ZHENenergy_progress
11/23/2022Construction Operations Influencing Adjacent StructuresYU YE ZHENspecial
11/23/2022Structural Stability – Alterations of existing buildingsYU YE ZHENspecial
Latest 25 of 26.
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/28/2026B08011928-P1Request digital key ↗
08/27/2026B08011935-P2Request digital key ↗
08/26/2026B08011941-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B08011928-I1Open ↗
08/13/2026B08011928-P1Open ↗
▸DOB NOWRestrictive Declaration/Easement 22
08/13/2026B08011928-I1Open ↗
08/13/2026B08011928-P1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026B08011928-I1Open ↗
09/01/2026B08011928-I1Open ↗
08/30/2026B08011941-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/28/2026B08011928-I1Open ↗
08/28/2026B08011928-S1Open ↗
08/28/2026B08011928-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026B08011928-I1Open ↗
08/30/2026B08011941-I1Open ↗
08/28/2026B08011928-P1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/28/2026B08011928-P1Open ↗
08/27/2026B08011935-P2Open ↗
08/26/2026B08011941-P1Open ↗
Showing 3 of 7 on file for this type