← Back
Four families
95-02 43 AVENUE
QUEENS · Elmhurst · BIN 4039992
💬 Discuss this project
1931Year Built
2Stories
C3Building Class
R5Zoning
3,040 sfGross Floor Area
4Units
Rent Stabilized0 Open Violations
Four families · Owner of record: 43 AVE ALLIANCE LLC · 2,500 sf lot · 1.22 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
43 AVE ALLIANCE LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/21/2023$1.1M—Private party → 43 AVE ALLIANCE LLC$372/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PIROOZ ENGINEERING, P.C.310/16/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OMEGA STUCCO CORPGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARC CONSULTING ENGINEERS,4083104/02/2024
Building Lifecycle
All (22)Filed (3)Permit Issued (2)Signed Off (2)Violation (9)Inspection (1)Special Inspection (5)
06/11/2025
Violation issued (HPD, closed)
A
03/05/2025
Signed off — Alteration
Q01018336-I1
03/04/2025
Signed off — Alteration
Q01018343-I1
02/28/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/02/2024
Violation issued (HPD, closed)
I
10/17/2024
Special inspection requirement — Tenant Protection Plan Compliance
JAN PEREZ
10/17/2024
Special inspection requirement — Preliminary
PIROOZ SOLTANIZADEH
10/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
PIROOZ SOLTANIZADEH
10/17/2024
Special inspection requirement — Energy Code Compliance Inspections
PIROOZ SOLTANIZADEH
10/17/2024
Special inspection requirement — Insulation placement and R values
PIROOZ SOLTANIZADEH
10/16/2024
Filed — Alteration
Q01018336-P1
05/01/2024
Permit issued — General Construction
Q01018336-I1-GC
04/12/2024
Violation issued (HPD, closed)
A
04/02/2024
Filed — Alteration
Q01018336-I1
03/29/2024
Permit issued — Construction Fence
Q01018343-I1-FN
03/13/2024
Filed — Alteration
Q01018343-I1
11/24/2023
Violation issued (HPD, closed)
I
03/28/2023
Violation issued (HPD, closed)
A
11/15/2022
Violation issued (HPD, closed)
I
03/03/2022
Violation issued (HPD, closed)
A
03/03/2022
Violation issued (HPD, closed)
I
04/14/2021
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offOMEGA STUCCO CORP05/01/2024
DOB NOWConstruction FenceSigned-offOMEGA STUCCO CORP03/29/2024
1 project · most recent 03/29/2024
FiledStatusContractorScope
03/29/2024Permit IssuedE D ELECTRICAL INC5 meters, 5 new_meters
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
02/28/2025Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
10/17/2024Tenant Protection Plan ComplianceJAN PEREZspecial
10/17/2024PreliminaryPIROOZ SOLTANIZADEHprogress
10/17/2024Fire-Resistance Rated ConstructionPIROOZ SOLTANIZADEHprogress
10/17/2024Energy Code Compliance InspectionsPIROOZ SOLTANIZADEHprogress
10/17/2024Insulation placement and R valuesPIROOZ SOLTANIZADEHenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q01018343-I1Request digital key ↗
08/21/2026Q01018336-I1Request digital key ↗
08/21/2026Q01018336-P1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q01018343-I1Open ↗
08/21/2026Q01018336-I1Open ↗
08/21/2026Q01018336-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01018336-I1Open ↗
08/28/2026Q01018336-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01018336-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01018336-I1Open ↗
08/21/2026Q01018336-P1Open ↗