← Back
Two family frame
95-13 91 STREET
QUEENS · Ozone Park (North) · BIN 4187554
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R4-1Zoning
1,615 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,200 sf lot · 0.73 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC201/15/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802201/15/2025
Building Lifecycle
All (13)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Objection (2)Special Inspection (5)
03/04/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01143156-I1
01/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
01/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
01/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
01/28/2025
Special inspection requirement — Final
Kaijin Liang
01/28/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
01/15/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01143156-P1
12/30/2024
Permit issued — Solar
Q01143156-I1-SL
12/11/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Admin
11/26/2024
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01143156-I1
09/08/2006
Violation issued (ECB, closed)
Quality of Life
09/08/2006
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP12/30/2024
1 project · most recent 11/11/2024
FiledStatusContractorScope
11/11/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/28/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
01/28/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
01/28/2025Energy Code Compliance InspectionsKaijin Liangprogress
01/28/2025FinalKaijin Liangprogress
01/28/2025Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01143156-I1Request digital key ↗
08/21/2026Q01143156-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q01143156-I1Open ↗
08/23/2026Q01143156-I1Open ↗
08/23/2026Q01143156-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01143156-P1Open ↗
08/13/2026Q01143156-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01143156-I1Open ↗
08/23/2026Q01143156-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01143156-P1Open ↗
08/13/2026Q01143156-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01143156-I1Open ↗