| Owner | Filings | Most Recent |
|---|---|---|
| NYC SCHOOL CONSTRUCTION AUTHORITY | 17 | 08/22/2026 |
| NYC SCHOOL CONSTRUCTION | 11 | 07/08/2026 |
| NYC DEPARTMENT OF EDUCATION | 1 | 03/22/2026 |
| DEPARTMENT OF EDUCATION 0 | 1 | 03/22/2026 |
| DOE PS 262/306 | 3 | 03/22/2026 |
| DOE P.S. 262 | 1 | 03/22/2026 |
| CITNALTA CONSTRUC CORP | 3 | 03/22/2026 |
| CITNALTA CONSTRUCTION COR | 3 | 03/22/2026 |
| P.S.262 (PS306) D.O.E. | 2 | 03/22/2026 |
| NYC SCHOOL CONST AUTHORITY | 3 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| BLADYKAS ENGINEERING, P.C. | 3 | 02/03/2025 |
| DSENY ENGINEERING SERVICES, PC | 3 | 11/15/2024 |
| DI DOMENICO + PARTNERS LLP | 1 | 03/18/2024 |
| SEVERUD ASSOCIATES CONSULTING ENGIN | 1 | 03/16/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| DSENY ENGINEERING SERVICES | 6 | 03/21/2026 |
| BLADYKAS ENGINEERING, P.C. | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| WHITESTONE CONSTRUCTION CORP | General Contractor | 11 | 07/08/2026 |
| CHARAN ELEC'L ENTERP'S IN | Electrical | 2 | 03/22/2026 |
| SPYRIDON ILIADIS | Electrical | 2 | 03/21/2026 |
| AJIT ONE MECH & GEN CONTR | Fire Protection | 2 | 08/22/2026 |
| ACS SYSTEM ASSOCIATES INC. | General Contractor | 2 | 07/08/2026 |
| FORSYTHE PLBG & HTG CORP | Plumbing | 2 | 07/08/2026 |
| HEXAGON CONST & ELECL GRP | Electrical | 1 | 03/22/2026 |
| C.B. MILLS ELECTRIC LLC | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| UNIVERSAL TESTING AND INS | 400 | 5 | 11/15/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | AJIT ONE MECH & GEN CONTR | 08/21/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | WHITESTONE CONSTRUCTION CORP | 07/01/2026 |
| DOB NOW | Structural | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/26/2026 |
| DOB NOW | General Construction | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/26/2026 |
| DOB NOW | Supported Scaffold | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/26/2026 |
| DOB NOW | Plumbing | Permit Issued | FORSYTHE PLBG & HTG CORP | 06/17/2026 |
| DOB NOW | Construction Fence | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/16/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | ACS SYSTEM ASSOCIATES INC. | 04/22/2026 |
| DOB NOW | Plumbing | Permit Issued | HAR JI PLBG & HTG CORP | 08/20/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | ACS SYSTEM ASSOCIATES INC. | 06/24/2025 |
| DOB NOW | General Construction | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/13/2025 |
| DOB NOW | Structural | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/12/2025 |
| DOB NOW | Sprinklers | Permit Issued | FORSYTHE PLBG & HTG CORP | 06/12/2025 |
| DOB NOW | Sidewalk Shed | Permit Issued | WHITESTONE CONSTRUCTION CORP | 06/11/2025 |
| DOB NOW | Supported Scaffold | Permit Issued | WHITESTONE CONSTRUCTION CORP | 05/20/2025 |
| DOB NOW | Construction Fence | Permit Issued | WHITESTONE CONSTRUCTION CORP | 05/20/2025 |
| BIS | EQ | ISSUED | CITNALTA CONSTRUCTION | 11/13/2009 |
| BIS | PL | ISSUED | FRANCO BELLI P&H&SONS INC | 09/03/2009 |
| BIS | PL | ISSUED | FRANCO BELLI P&H&SONS INC | 09/03/2009 |
| BIS | SP | ISSUED | ASCO SPRINKLER CO.,INC | 12/30/2008 |
| BIS | — | ISSUED | CITNALTA CONSTRUCTION | 11/12/2008 |
| BIS | PL | ISSUED | FRANCO BELLI PLUMBING & HTG &SON | 09/15/2008 |
| BIS | FP | ISSUED | FIREMASTERS | 04/23/2008 |
| BIS | SP | ISSUED | ASCO SPRINKLER CO.,INC | 02/15/2008 |
| BIS | SP | ISSUED | ASCO SPRINKLER CO.,INC | 01/11/2008 |
| BIS | PL | ISSUED | FRANCO BELLI PLUMBING & HTG &SON | 09/24/2007 |
| BIS | PL | ISSUED | FRANCO BELLI PLUMBING & HTG &SON | 09/24/2007 |
| BIS | EQ | ISSUED | CITNALTA CONSTRUCTION CORP | 08/06/2007 |
| BIS | EQ | ISSUED | CITNALTA CONSTRUCTION CORP | 12/15/2006 |
| BIS | SP | ISSUED | ASCO SPRINKLER CO.,INC | 10/19/2006 |
| BIS | — | ISSUED | CITNALTA CONSTRUCTION CORP | 10/13/2006 |
| BIS | PL | ISSUED | FRANCO BELLI PLUMBING & HTG &SON | 10/13/2006 |
| BIS | PL | ISSUED | FRANCO BELLI PLUMBING & HTG &SON | 10/13/2006 |
| BIS | EQ | ISSUED | CITNALTA CONSTRUCTION CORP | 10/12/2006 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/03/2025 | Permit Issued | WHITESTONE CONSTRUCTION C | Heating and Air Conditioning Systems, Others, Refrigeration Systems | Heat / Cool Scott Springfield Custom 118 tons · Rooftop Unit ×4 Refrigeration Mitsubishi Electric PCA-A24KA8 24,000 BTU · Vrf Indoor ×4 PUZ-A24NHA7 24,000 BTU · Heat Pump Outdoor ×4 PCA-A30KA8 30,000 BTU · Vrf Indoor ×2 PUY-A30NHA7 30,000 BTU · Heat Pump Outdoor ×2 Other Greenheck GB-098-6 355 CFM · Exhaust Fan ×4 GB-099-3 800 CFM · Exhaust Fan ×2 GB-100-3 925 CFM · Exhaust Fan ×2 GB-100-4 750 CFM · Exhaust Fan ×2 GB-160HP-4 1,100 CFM · Exhaust Fan ×2 GB-220-10 3,600 CFM · Exhaust Fan ×2 GB0974 200 CFM · Exhaust Fan ×2 GB140HP4 725 CFM · Exhaust Fan ×2 USF-10 825 CFM · Exhaust Fan ×2 USF-4 120 CFM · Exhaust Fan ×2 Berko HUHAA320 3 kW · Electric Heater ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/18/2026 | Permit Issued | A & S ELECTRIC INC. | General Wiring |
| 09/29/2025 | Permit Issued | HEXAGON CONST & ELECL GRP | — |
| 06/10/2025 | Permit Issued | HEXAGON CONST & ELECL GRP | — |
| 12/21/2024 | Permit Issued | HEXAGON CONST & ELECL GRP | General Wiring |
| 12/21/2024 | Permit Issued | HEXAGON CONST & ELECL GRP | General Wiring |
| 07/19/2023 | Complete | C.B. MILLS ELECTRIC LLC | 1 meters, 1 new_meters |
| 04/09/2023 | Complete | JTE ELECTRICAL SERVICES | General Wiring |
| 06/22/2022 | Complete | PRINCE ELECTRIC CORP. | — |
| 01/14/2020 | Complete | CHARAN ELEC'L ENTERP'S IN | — |
| 11/27/2019 | Complete | CHARAN ELEC'L ENTERP'S IN | — |
| 07/15/2019 | Complete | CHARAN ELEC'L ENTERP'S IN | General Wiring |
| 05/21/2018 | Complete | CHARAN ELEC'L ENTERP'S IN | — |
| 05/03/2018 | Complete | CHARAN ELEC'L ENTERP'S IN | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/03/2025 | Permit Issued | AJIT ONE MECH & GEN CONTR | Steel |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/04/2025 | Fire-Resistant Penetrations and Joints | NELSON LOPEZ | special |
| 02/04/2025 | Mechanical Systems | NELSON LOPEZ | special |
| 02/04/2025 | Post-installed Anchors | NELSON LOPEZ | special |
| 02/04/2025 | Final | NELSON LOPEZ | progress |
| 02/04/2025 | Duct leakage testing, insulation and design | NELSON LOPEZ | energy_progress |
| 02/04/2025 | Electrical motors and elevators | NELSON LOPEZ | energy_progress |
| 02/04/2025 | HVAC-R and service water piping design and insulation | NELSON LOPEZ | energy_progress |
| 02/04/2025 | Shutoff dampers | NELSON LOPEZ | energy_progress |
| 02/04/2025 | Maintenance information | NELSON LOPEZ | energy_progress |
| 02/04/2025 | HVAC-R and service water heating equipment | NELSON LOPEZ | energy_progress |
| 02/04/2025 | HVAC-R and service water heating system controls | NELSON LOPEZ | energy_progress |
| 01/30/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 01/30/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 01/30/2025 | Mechanical Systems | — | special |
| 01/30/2025 | Post-installed Anchors | — | special |
| 01/30/2025 | Final | — | progress |
| 01/30/2025 | Duct leakage testing, insulation and design | — | energy_progress |
| 01/30/2025 | Maintenance information | — | energy_progress |
| 01/30/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 01/30/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 01/30/2025 | Electrical motors and elevators | — | energy_progress |
| 01/30/2025 | Shutoff dampers | — | energy_progress |
| 10/22/2024 | Post-installed Anchors | NELSON LOPEZ | special |
| 04/03/2024 | Insulation placement and R values | NELSON LOPEZ | energy_progress |
| 03/13/2024 | Structural Steel - Details | NELSON LOPEZ | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Ps306q | Education | — | Project Q01130513 Project Q01130517 |