← Back
Two stories - detached, small or mid-size
95-20 134 STREET
QUEENS · South Richmond Hill · BIN 4200273
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R4AZoning
1,204 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: MENDEZ AS TO 1% INTEREST, WILLIAM G · 2,521 sf lot · 0.48 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/29/2024$665K—— → —$552/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC103/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMPACITY ELECTRICAL INCElectrical103/22/2026
SURF CLEAN ENERGY INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244103/05/2025
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Violation (3)Special Inspection (5)
03/11/2025
Permit issued — Solar
Q01190317-I1-SL
03/05/2025
Filed — Alteration
info@nybuildingassociates.com
Q01190317-I1
03/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/05/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/05/2025
Special inspection requirement — Final
NARESH MAHANGU
03/05/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
10/23/1999
Violation issued (ECB, closed)
Quality of Life
10/23/1999
Violation issued (ECB, closed)
Quality of Life
10/23/1999
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC03/11/2025
2 projects · most recent 02/25/2025
FiledStatusContractorScope
02/25/2025CompleteAMPACITY ELECTRICAL INC—
04/24/2024Permit IssuedISLAND ELECTRIC CORP—
1 project · most recent 03/05/2025
FiledStatusContractorScope
03/05/2025Permit IssuedSURF CLEAN ENERGY INC13 panels, 5.52 kw, 2,300 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/05/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/05/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/05/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/05/2025FinalNARESH MAHANGUprogress
03/05/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01190317-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q01190317-I1Open ↗
09/01/2026Q01190317-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01190317-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q01190317-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01190317-I1Open ↗