| Owner | Filings | Most Recent |
|---|---|---|
| PARSONS CONSTRUCTION | 12 | 03/22/2026 |
| ROCK BUILDERS | 1 | 03/22/2026 |
| 103 W 162ND LLC | 3 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/31/2022 | $665K | — | — → — | — not available |
| 11/06/2017 | $370K | — | OGDEN PARKING LLC → Private party | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| DJLU ARCHITECT | 5 | 10/24/2023 |
| ADVANCED ENGINEERING & INSPECT. PLL | 8 | 10/23/2023 |
| AP PROFESSIONAL ENGINEERING PLLC | 3 | 05/24/2023 |
| ELEVATED ENGINEERING NYC | 7 | 05/15/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| SPEEDY EXPEDITING | 40 | 03/21/2026 |
| SANDEEP KAUR | 3 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ROCK BUILDERS INC | General Contractor | 16 | 07/08/2026 |
| PARSONS CONSTRUCTION INC | General Contractor | 6 | 03/21/2026 |
| PARK MANAGEMENT USA CORP | General Contractor | 5 | 07/08/2026 |
| POWER DIRECT ELECTRIC INC | Electrical | 1 | 03/22/2026 |
| BRUCHE MECHANICAL NY LLC | Fire Protection | 1 | 07/08/2026 |
| TRUE POWER ELECL CONT LLC | Electrical | 1 | 03/22/2026 |
| PLBG P & H INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| REGIONAL TESTING CORP. | 394 | 16 | 10/24/2023 |
| HRF SERVICES CORP | 5616 | 2 | 01/17/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | ROCK BUILDERS INC | 05/30/2023 |
| DOB NOW | Plumbing | Signed-off | PLBG P & H INC | 05/18/2023 |
| DOB NOW | Sprinklers | Signed-off | BRUCHE MECHANICAL NY LLC | 05/16/2023 |
| DOB NOW | Supported Scaffold | Signed-off | PARSONS CONSTRUCTION INC | 05/02/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | PARSONS CONSTRUCTION INC | 04/25/2023 |
| DOB NOW | Foundation | Signed-off | ROCK BUILDERS INC | 03/31/2023 |
| DOB NOW | Structural | Signed-off | ROCK BUILDERS INC | 03/31/2023 |
| DOB NOW | General Construction | Permit Issued | ROCK BUILDERS INC | 03/28/2023 |
| DOB NOW | Mechanical Systems | Signed-off | ROCK BUILDERS INC | 03/24/2023 |
| DOB NOW | Support of Excavation | Signed-off | ROCK BUILDERS INC | 09/28/2022 |
| DOB NOW | Foundation | Signed-off | ROCK BUILDERS INC | 09/28/2022 |
| DOB NOW | Construction Fence | Signed-off | ROCK BUILDERS INC | 09/28/2022 |
| DOB NOW | Support of Excavation | Signed-off | PARK MANAGEMENT USA CORP | 06/21/2022 |
| DOB NOW | Construction Fence | Signed-off | PARK MANAGEMENT USA CORP | 06/10/2022 |
| DOB NOW | Foundation | Signed-off | PARK MANAGEMENT USA CORP | 06/10/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/24/2023 | Permit Issued | ROCK BUILDERS INC | Heating and Air Conditioning Systems | Heat / Cool Daikin 3MXS24WMVJU9 24,000 BTU · Heat Pump Outdoor ×10 5MXS48TVJU 47,000 BTU · Heat Pump Outdoor ×8 4MXS36WMVJU9 36,000 BTU · Heat Pump Outdoor ×4 RX12BXVJU 10,900 BTU · Heat Pump Outdoor ×4 RX36NMVJU 34,400 BTU · Heat Pump Outdoor ×2 RXTQ36TBVJUA 34,200 BTU · Vrf Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/24/2023 | Signed-off | PLBG P & H INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/24/2023 | Signed-off | BRUCHE MECHANICAL NY LLC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/22/2023 | Complete | POWER DIRECT ELECTRIC INC | 16 meters, 2 new_meters |
| 11/21/2023 | Complete | POWER DIRECT ELECTRIC INC | — |
| 10/25/2023 | Complete | POWER DIRECT ELECTRIC INC | — |
| 07/12/2023 | Complete | POWER DIRECT ELECTRIC INC | General Wiring |
| 05/07/2023 | Complete | BDS ELECTRIC CORP. | — |
| 04/27/2023 | Complete | TRUE POWER ELECL CONT LLC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/24/2023 | Permit Issued | ROCK BUILDERS INC | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/24/2023 | Permit Issued | ROCK BUILDERS INC | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/13/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/30/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/26/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 10/24/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/22/2023 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 06/12/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 06/12/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 02/13/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/12/2022 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/30/2023 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 10/30/2023 | Exterior Insulation and Finish Systems (EIFS) | Paul Raymond | special |
| 10/30/2023 | Energy Code Compliance Inspections | Paul Raymond | progress |
| 10/30/2023 | Fire-Resistance Rated Construction | Paul Raymond | progress |
| 10/30/2023 | Fenestration areas | Paul Raymond | energy_progress |
| 10/30/2023 | Air barrier - visual inspection | Paul Raymond | energy_progress |
| 10/30/2023 | Fenestration air leakage | Paul Raymond | energy_progress |
| 10/30/2023 | Fenestration and door U-factor and product ratings | Paul Raymond | energy_progress |
| 10/30/2023 | Maintenance information | Paul Raymond | energy_progress |
| 10/30/2023 | Lighting controls | Paul Raymond | energy_progress |
| 10/30/2023 | Metering | Paul Raymond | energy_progress |
| 10/30/2023 | Interior lighting power | Paul Raymond | energy_progress |
| 10/30/2023 | Insulation placement and R values | Paul Raymond | energy_progress |
| 10/30/2023 | Protection of exposed foundation insulation | Paul Raymond | energy_progress |
| 10/30/2023 | Air barrier — testing | Paul Raymond | energy_progress |
| 10/30/2023 | Exterior lighting power | Paul Raymond | energy_progress |
| 10/30/2023 | Lighting in dwelling units | Paul Raymond | energy_progress |
| 10/24/2023 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 10/24/2023 | Sprinkler Systems | Paul Raymond | special |
| 10/16/2023 | Energy Code Compliance Inspections | Paul Raymond | progress |
| 10/16/2023 | Maintenance information | Paul Raymond | energy_progress |
| 10/16/2023 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 10/16/2023 | HVAC-R and service water heating equipment | Paul Raymond | energy_progress |
| 10/16/2023 | HVAC-R and service water heating system controls | Paul Raymond | energy_progress |
| 10/16/2023 | HVAC-R and service water piping design and insulation | Paul Raymond | energy_progress |