← Back
BuildNYC
Two family converted from one family
957 FTELEY AVENUE
BRONX · BIN 2086996
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R6Zoning
2,557 sfGross Floor Area
2Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Two family converted from one family · 2,700 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof2p · 1 filing · 9 docs
Floor 25p · 1 filing · 11 docs
Floor 1
Cellar5p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Ers Foundation403/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/06/2021$749K—Private party → Private party$293/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Tom Petersen Architect103/28/2025
Thomas J. Curro Architect204/05/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Smart Line ElectricElectrical503/22/2026
Catizone ElectricalElectrical203/21/2026
Interstate ElectricElectrical103/22/2026
Excelsior Design ConstructionGeneral Contractor103/21/2026
Long Island Power Solutionsspecialty_contractor107/08/2026
New York Standard MechanicalPlumbing107/08/2026
Joey BarranGeneral Contractor106/29/2011
Sadagat AliGeneral Contractor312/09/2011
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Thomas Petersen Architect7854103/28/2025
Thomas J. Curro Architect718204/05/2021
Building Lifecycle
11/24/2025
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
06/20/2025
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
X01202441-I1
04/04/2025
Permit issued — Solar
X01202441-I1-SL
03/28/2025
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
X01202441-I1
03/28/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
37 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offLong Island Power Solutions04/04/2025
DOB NOWPlumbingSigned-offNew York Standard Mechanical12/22/2020
BIS—ISSUEDExcelsior Design & Construction01/07/2021
BIS—ISSUEDSadagat Ali12/09/2011
BISEQISSUEDSadagat Ali12/09/2011
BISOTISSUEDSadagat Ali10/31/2011
BISOTISSUEDJoey Barran06/29/2011
1 project · most recent 04/05/2021
Gas Water/Sanitary
FiledStatusContractorScope
04/05/2021Signed-offNew York Standard MechanicalGas, Water/Sanitary
7 projects · most recent 03/27/2025
General Wiring
FiledStatusContractorScope
03/27/2025CompleteCatizone Electrical—
02/07/2025CompleteSmart Line ElectricGeneral Wiring
01/29/2025CompleteSmart Line Electric—
12/17/2024CompleteSmart Line ElectricGeneral Wiring
06/14/2021CompleteL J Electrical ServiceGeneral Wiring
01/26/2021CompleteInterstate ElectricGeneral Wiring
08/29/2020CompleteInterstate ElectricGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/28/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
03/28/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/28/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/28/2025Energy Code Compliance InspectionsTOM PETERSENprogress
03/28/2025FinalTOM PETERSENprogress
03/24/2021Fire-Resistant Penetrations and JointsTHOMAS CURROspecial
03/24/2021Energy Code Compliance InspectionsTHOMAS CURROprogress
09/29/2020Fire-Resistant Penetrations and JointsTHOMAS CURROspecial
09/29/2020Energy Code Compliance InspectionsTHOMAS CURROprogress
09/29/2020Fire-Resistance Rated ConstructionTHOMAS CURROprogress
82 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account