← Back
Single or multiple dwelling with stores or offices
9602 CHURCH AVENUE
BROOKLYN · East Flatbush-Remsen Village · BIN 3103595
💬 Discuss this project
1931Year Built
3Stories
S9Building Class
R6Zoning
5,220 sfGross Floor Area
9Units
Rent Stabilized12 Open Violations 11 unresolved · 1 paperwork only ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: BELISHA TWO INC. · 2,000 sf lot · 2.61 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalEquipmentGeneral
Roof7p · 2 filings · 11 docs
Floor 35p · 1 filing · 5 docs
Floor 2
Floor 12p · 1 filing · 6 docs
Site & exterior5p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EDEN GENERAL CONSTRUCTION INC407/08/2026
NEW YORK CITY PRIME407/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VOLUME SPACE CONSULTING INC.108/15/2024
IKRA CONSULTING LLC108/05/2024
NY BUILDING ASSOCIATES INC107/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AK CONSULTING SERVICES203/21/2026
GREEN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EDEN GENERAL CONSTR INCGeneral Contractor107/08/2026
NEW YORK CITY PRIME CORPGeneral Contractor107/08/2026
NY BUILDING ASSOCIATES INGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AK CONSULTING SERVICES, I6198108/05/2024
NKM ENGINEERING PLLC6244107/16/2024
Building Lifecycle
All (45)Filed (3)Permit Issued (3)Signed Off (3)Violation (19)Objection (4)Special Inspection (13)
01/02/2025
Signed off — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01095398-I1
11/07/2024
Signed off — Alteration
FILE MECHANICAL WORK ON 1ST FLOOR STORE OF MIXED USE BUILDING TO REPLACE KITCHEN DUCT AND EXHAUST FAN, INSTALL NEW SPLIT A/C UNIT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01080435-I1
10/16/2024
Signed off — Alteration
FACADE RESTORATION WORK AS PER INDICATED ON PLAN AND ADDRESS THE ECB VIOLATION NUMBER: 39115550H. THERE WILL BE NO CHANGE IN THE USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01090750-I1
08/15/2024
Filed — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01095398-I1
08/15/2024
Permit issued — Sidewalk Shed
B01095398-I1-SH
08/12/2024
Permit issued — General Construction
B01090750-I1-GC
08/05/2024
Filed — Alteration
FACADE RESTORATION WORK AS PER INDICATED ON PLAN AND ADDRESS THE ECB VIOLATION NUMBER: 39115550H. THERE WILL BE NO CHANGE IN THE USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01090750-I1
08/05/2024
Permit issued — Mechanical Systems
B01080435-I1-MS
08/02/2024
Special inspection requirement — Masonry
MAHFUZAR RAHMAN
08/02/2024
Special inspection requirement — Final
MAHFUZAR RAHMAN
08/02/2024
Special inspection requirement — Tenant Protection Plan Compliance
MAHFUZAR RAHMAN
08/02/2024
Special inspection requirement — Energy Code Compliance Inspections
MAHFUZAR RAHMAN
07/24/2024
Objection resolved — Addressed
07/24/2024
Objection resolved — Addressed
07/22/2024
Objection raised — Fire_Protection
07/22/2024
Objection raised — Other
07/16/2024
Filed — Alteration
FILE MECHANICAL WORK ON 1ST FLOOR STORE OF MIXED USE BUILDING TO REPLACE KITCHEN DUCT AND EXHAUST FAN, INSTALL NEW SPLIT A/C UNIT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01080435-I1
07/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
07/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
07/15/2024
Special inspection requirement — Tenant Protection Plan Compliance
NARESH MAHANGU
07/15/2024
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
07/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
07/15/2024
Special inspection requirement — Duct leakage testing, insulation and design
NARESH MAHANGU
07/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
07/12/2024
Special inspection requirement — Final
ARIEL GOLSHAN
07/12/2024
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
05/30/2024
Violation issued (ECB, open)
Construction
05/30/2024
Violation issued (ECB, closed)
Unknown
02/23/2022
Violation issued (HPD, closed)
A
04/07/2021
Violation issued (HPD, closed)
A
12/13/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/03/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/27/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/16/1999
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/19/1998
Violation issued (ECB, closed)
Boilers
09/16/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/10/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/01/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/16/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/01/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/17/1991
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offNEW YORK CITY PRIME CORP08/15/2024
DOB NOWGeneral ConstructionSigned-offEDEN GENERAL CONSTR INC08/12/2024
DOB NOWMechanical SystemsSigned-offNY BUILDING ASSOCIATES IN08/05/2024
2 projects · most recent 08/28/2025
General Wiring
FiledStatusContractorScope
08/28/2025Permit IssuedAMERICAN POWER ELECT CONS10 meters, 1 new_meters
06/12/2024CompleteE D ELECTRICAL INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/02/2024MasonryMAHFUZAR RAHMANspecial
08/02/2024FinalMAHFUZAR RAHMANprogress
08/02/2024Tenant Protection Plan ComplianceMAHFUZAR RAHMANspecial
08/02/2024Energy Code Compliance InspectionsMAHFUZAR RAHMANprogress
07/15/2024HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
07/15/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
07/15/2024Tenant Protection Plan ComplianceNARESH MAHANGUspecial
07/15/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
07/15/2024HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
07/15/2024Duct leakage testing, insulation and designNARESH MAHANGUenergy_progress
07/15/2024HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
07/12/2024FinalARIEL GOLSHANprogress
07/12/2024Mechanical SystemsNARESH MAHANGUspecial
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026B01080435-I1Request digital key ↗
08/24/2026B01090750-I1Request digital key ↗
08/24/2026B01095398-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B01090750-I1Open ↗
09/01/2026B01080435-I1Open ↗
09/01/2026B01080435-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026B01080435-I1Open ↗
08/24/2026B01095398-I1Open ↗
08/13/2026B01090750-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01090750-I1Open ↗
09/01/2026B01080435-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01090750-I1Open ↗