| Owner | Filings | Most Recent |
|---|---|---|
| NYC Parks | 16 | 07/08/2026 |
| City of New York - Parks and Rec | 4 | 03/21/2026 |
| NYC Department of Design and Construction | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| SRW Engineers | 6 | 05/05/2025 |
| Tan Engineering | 3 | 01/12/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| Municipal Building Consultants | 6 | 03/21/2026 |
| Studio C Architects | 6 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PNV Industries | General Contractor | 6 | 03/21/2026 |
| Prestigious Maintenance I | General Contractor | 3 | 03/21/2026 |
| Jpi Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| McManus Mechanical Maintenance P&H | Plumbing | 1 | 07/08/2026 |
| Northeast Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Crosscheck Inspection Services | 544 | 6 | 05/05/2025 |
| Tan Engineering | 1291 | 2 | 01/12/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | Jpi Plumbing & Heating | 01/27/2025 |
| DOB NOW | Plumbing | Signed-off | Northeast Plumbing & Heating | 11/09/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | PNV Industries | 10/21/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | PNV Industries | 04/06/2022 |
| DOB NOW | Plumbing | Signed-off | McManus Mechanical Maintenance P&H | 06/23/2021 |
| DOB NOW | Mechanical Systems | Permit Issued | Prestigious Maintenance I | 06/23/2021 |
| BIS | FP | ISSUED | Allied Fire Control Services | 06/28/2013 |
| BIS | FP | ISSUED | Allied Fire Control Services | 06/28/2013 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/12/2024 | Permit Issued | Prestigious Maintenance I | Ventilation Systems | Ventilation Accurex XUEF-13 2,000 CFM · Exhaust Fan ×2 |
| 09/12/2023 | Permit Issued | PNV Industries | Heating Systems | Heating Sterling PV10A1B01A43R30B1H1H2 100,000 BTU · Rooftop Unit ×2 PV25A11G01A43T5CB1H1H2 250,000 BTU · Rooftop Unit ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/05/2025 | Signed-off | Jpi Plumbing & Heating | Gas |
| 06/14/2021 | Signed-off | McManus Mechanical Maintenance P&H | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/25/2022 | Permit Issued | C.falco Eletl Cont | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/10/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/30/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/10/2025 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 09/24/2021 | Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish | Certified | View ↗ |
| 09/22/2021 | Certified Sprinkler (PL)-Sprinkler-Hydro | Certified | View ↗ |
| 07/14/2021 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 07/09/2021 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/15/2025 | Fire-Resistant Penetrations and Joints | EUGENE BIFULCO | special |
| 05/15/2025 | Post-installed Anchors | EUGENE BIFULCO | special |
| 05/01/2025 | Fire-Resistant Penetrations and Joints | EUGENE BIFULCO | special |
| 05/01/2025 | Post-installed Anchors | EUGENE BIFULCO | special |
| 01/17/2024 | HVAC-R and service water heating system controls | Roger Tan | energy_progress |
| 01/17/2024 | Energy Code Compliance Inspections | Roger Tan | progress |
| 01/17/2024 | Final | Roger Tan | progress |
| 01/17/2024 | Mechanical Systems | Roger Tan | special |
| 01/17/2024 | Fire-Resistant Penetrations and Joints | Roger Tan | special |
| 01/17/2024 | Maintenance information | Roger Tan | energy_progress |
| 01/17/2024 | HVAC-R and service water heating equipment | Roger Tan | energy_progress |
| 01/17/2024 | HVAC-R and service water piping design and insulation | Roger Tan | energy_progress |
| 01/16/2024 | Post-installed Anchors | EUGENE BIFULCO | special |
| 01/16/2024 | Fire-Resistant Penetrations and Joints | EUGENE BIFULCO | special |
| 01/11/2024 | Maintenance information | Roger Tan | energy_progress |
| 01/11/2024 | HVAC-R and service water heating system controls | Roger Tan | energy_progress |
| 01/11/2024 | Final | Roger Tan | progress |
| 01/11/2024 | Energy Code Compliance Inspections | Roger Tan | progress |
| 01/11/2024 | Mechanical Systems | Roger Tan | special |
| 01/11/2024 | Fire-Resistant Penetrations and Joints | Roger Tan | special |
| 01/11/2024 | HVAC-R and service water piping design and insulation | Roger Tan | energy_progress |
| 01/11/2024 | HVAC-R and service water heating equipment | Roger Tan | energy_progress |
| 10/08/2023 | Mechanical Systems | EUGENE BIFULCO | special |
| 10/08/2023 | HVAC-R and service water heating system controls | EUGENE BIFULCO | energy_progress |
| 10/08/2023 | Maintenance information | EUGENE BIFULCO | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Seany Slices | Restaurant / Food Service | Floor 1, Roof | Project Q00531701 Project Q00531947 |