← Back
Miscellaneous two family
971 BERGEN STREET
BROOKLYN · BIN 3030294
💬 Discuss this project
1915Year Built
2Stories
B9Building Class
R6BZoning
2,840 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Miscellaneous two family · 2,209 sf lot · 1.29 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction34p · 1 filing · 20 docs
PenthouseUnder Construction31p · 1 filing · 20 docs
Floor 4Under Construction32p · 1 filing · 20 docs
Floor 3Under Construction32p · 1 filing · 20 docs
Floor 2Under Construction32p · 1 filing · 20 docs
Floor 1Under Construction31p · 1 filing · 20 docs
CellarUnder Construction35p · 1 filing · 20 docs
1 job · most recent 05/04/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/04/2026Permit IssuedJ&J DESIGNS INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI SM36NAMHZ2 36,000 BTU · Heat Pump Outdoor ×3
MITSUBISHI MXZSM48NAM 48,000 BTU · Heat Pump Outdoor ×1
1 job · most recent 12/16/2025
General Wiring
FiledStatusContractorScope
12/16/2025Permit IssuedRONEY ELECTRIC INCGeneral Wiring
1 job · most recent 05/04/2026
Concrete
FiledStatusContractorScope
05/04/2026Permit IssuedJ&J DESIGNS INCConcrete
1 job · most recent 05/04/2026
Fence
FiledStatusContractorScope
05/04/2026Permit IssuedJ&J DESIGNS INCFence
Building Lifecycle
All (130)Filed (8)Permit Issued (7)Violation (2)Inspection (3)Objection (80)Special Inspection (30)
09/17/2026
Permit issued — Structural
B01226173-S5-ST
09/17/2026
Permit issued — Support of Excavation
B01226173-S6-SE
09/17/2026
Permit issued — Construction Fence
B01226173-S1-FN
07/29/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)
Certified
View inspection ↗
07/14/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
07/14/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
07/09/2026
Permit issued — Structural
B01226173-S5-ST
07/02/2026
Permit issued — Support of Excavation
B01226173-S6-SE
07/01/2026
Permit issued — General Construction
B01226173-I1-GC
06/23/2026
Permit issued — Construction Fence
B01226173-S1-FN
06/15/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Subgrade Inspections
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Exterior lighting power
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Preliminary
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Protection of exposed foundation insulation
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Lighting controls
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Lighting in dwelling units
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Fenestration areas
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Concrete - Cast-In-Place
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
06/15/2026
Special inspection requirement — Masonry
SHAHRIAR QUAYYUM
05/04/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' TEMPORARY CONSTRUCTION FENCE
B01226173-P1
05/04/2026
Special inspection requirement — Energy Code Compliance Inspections
05/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/04/2026
Special inspection requirement — Masonry
05/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/04/2026
Special inspection requirement — Concrete - Cast-In-Place
05/04/2026
Special inspection requirement — Subgrade Inspections
05/04/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
05/04/2026
Special inspection requirement — Preliminary
03/31/2026
Objection raised — Other
03/31/2026
Objection resolved — Addressed
03/31/2026
Objection resolved — Addressed
03/31/2026
Objection resolved — Addressed
03/23/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/17/2026
Objection resolved — Addressed
03/17/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/23/2026
Objection raised — Scope
02/11/2026
Objection resolved — Addressed
02/11/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
Latest 60 of 130 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BROOKLYN NORTH CAPITAL1309/18/2026
J J DESIGN NY609/18/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/15/2025$1.7M—Private party → RH BERGEN LLC$611/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC805/04/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DESIGNS INCGeneral Contractor709/18/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616611/18/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedJ&J DESIGNS INC09/17/2026
DOB NOWSupport of ExcavationPermit IssuedJ&J DESIGNS INC09/17/2026
DOB NOWConstruction FencePermit IssuedJ&J DESIGNS INC09/17/2026
DOB NOWStructuralPermit IssuedJ&J DESIGNS INC07/09/2026
DOB NOWSupport of ExcavationPermit IssuedJ&J DESIGNS INC07/02/2026
DOB NOWGeneral ConstructionPermit IssuedJ&J DESIGNS INC07/01/2026
DOB NOWConstruction FencePermit IssuedJ&J DESIGNS INC06/23/2026
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/29/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
07/14/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
07/14/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 73
DateRequirementInspectorRole
06/15/2026MasonrySHAHRIAR QUAYYUMspecial
06/15/2026Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
06/15/2026Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
06/15/2026Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
06/15/2026Lighting controlsSHAHRIAR QUAYYUMenergy_progress
06/15/2026Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
06/15/2026MeteringSHAHRIAR QUAYYUMenergy_progress
06/15/2026Lighting in dwelling unitsSHAHRIAR QUAYYUMenergy_progress
06/15/2026Exterior lighting powerSHAHRIAR QUAYYUMenergy_progress
06/15/2026Protection of exposed foundation insulationSHAHRIAR QUAYYUMenergy_progress
06/15/2026Insulation placement and R valuesSHAHRIAR QUAYYUMenergy_progress
06/15/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
06/15/2026Fenestration areasSHAHRIAR QUAYYUMenergy_progress
06/15/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
06/15/2026PreliminarySHAHRIAR QUAYYUMprogress
06/15/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
06/15/2026Structural Stability – Alterations of existing buildingsSHAHRIAR QUAYYUMspecial
06/15/2026Subsurface Investigations (Borings/Test Pits)SHAHRIAR QUAYYUMspecial
06/15/2026Subgrade InspectionsSHAHRIAR QUAYYUMspecial
06/15/2026Concrete - Cast-In-PlaceSHAHRIAR QUAYYUMspecial
06/15/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
05/04/2026Exterior lighting power—energy_progress
05/04/2026Concrete - Cast-In-Place—special
05/04/2026Fire-Resistant Penetrations and Joints—special
05/04/2026Masonry—special
Latest 25 of 73.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/21/2026B01226173-S6Request digital key ↗
08/21/2026B01226173-S5Request digital key ↗
08/21/2026B01226173-S4Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
09/23/2025340920472Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/21/2026B01226173-P1Open ↗
08/13/2026B01226173-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/21/2026B01226173-P1Open ↗
08/13/2026B01226173-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01226173-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026B01226173-S6Open ↗
08/21/2026B01226173-S5Open ↗
08/21/2026B01226173-S4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026B01226173-S6Open ↗
09/01/2026B01226173-S6Open ↗
08/31/2026B01226173-S5Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026B01226173-S5Open ↗
08/27/2026B01226173-S4Open ↗
08/27/2026B01226173-S2Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/23/2025340920472Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/21/2026B01226173-I1Open ↗
08/21/2026B01226173-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Trees Site Plan1
08/13/2026B01226173-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01226173-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026B01226173-S6Open ↗
08/21/2026B01226173-S5Open ↗
08/21/2026B01226173-S4Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT4
08/21/2026B01226173-P1Open ↗
08/13/2026B01226173-I1Open ↗
08/13/2026B01226173-S4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram3
08/13/2026B01226173-S4Open ↗
08/13/2026B01226173-S6Open ↗
08/13/2026B01226173-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/26/2025340920472Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
09/23/2025340920472Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
09/23/2025340920472Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/21/2026B01226173-P1Open ↗
08/13/2026B01226173-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/21/2026B01226173-P1Open ↗
08/13/2026B01226173-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/21/2026B01226173-I1Open ↗
08/21/2026B01226173-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/21/2026B01226173-S6Open ↗