← Back
Two family brick
974 THOMAS S BOYLAND ST
BROOKLYN · BIN 3082731
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R6Zoning
2,090 sfGross Floor Area
2Units
Two family brick · Owner of record: NOTE MASTERS, LLC (56% OWNER) · 2,350 sf lot · 0.89 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction2p · 1 filing · 5 docs
Floor 1Under Construction2p · 1 filing · 5 docs
CellarUnder Construction2p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GRATTAN DESIGN STUDIOS209/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/05/2023$750K—— → —$359/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RIVERSIDE ARCHITECTURE, PLLC204/03/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GRATTAN DESIGN STUDIOSGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIVERSIDE ARCHITECTURE9006104/03/2026
Building Lifecycle
All (5)Filed (2)Permit Issued (1)Special Inspection (2)
06/18/2026
Permit issued — General Construction
B01322690-I1-GC
04/03/2026
Filed — Alteration
This application is for Plumbing work as indicated on the plans submitted herewith. No change in use, egress, or occupancy.
B01322699-I1
04/03/2026
Filed — Alteration
MINOR INTERIOR RENOVATION AND DEMO PARTITIONS IN THE CELLAR, REPAIR ANDREPLACE THE DAMAGED WALLS, CEILING, FLOORS
B01322690-I1
03/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ira streitfeld
11/20/2025
Special inspection requirement — Final
ira streitfeld
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedGRATTAN DESIGN STUDIOS06/18/2026
1 project · most recent 04/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/03/2026——Gas, Water/Sanitary
1 project · most recent 07/17/2026
General Wiring
FiledStatusContractorScope
07/17/2026Permit IssuedGEMINI ELECTRIC CO., INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/27/2026Fire-Resistant Penetrations and Jointsira streitfeldspecial
11/20/2025Finalira streitfeldprogress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026B01322699-I1Request digital key ↗
08/17/2026B01322690-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026B01322699-I1Open ↗
08/17/2026B01322690-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026B01322690-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01322690-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/17/2026B01322690-I1Open ↗