← Back
Predominantly retail with other uses
975 EAST 233 STREET
BRONX · BIN 2097436
💬 Discuss this project
1930Year Built
2Stories
K4Building Class
R4Zoning
5,780 sfGross Floor Area
8Units
Rent Stabilized8 Open Violations 7 unresolved · 1 paperwork only ▸
Predominantly retail with other uses · Owner of record: HULU MGT LLC · 4,762 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction6p · 3 filings · 20 docs
Floor 1Under Construction11p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
J. WITKIN CONSULTING503/22/2026
C/O QV MANAGEMENT HULU MG203/22/2026
VANZO 233 PROPERTIES INC103/22/2026
HULO MGT LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/03/2018$1.3M—— → —$221/sf building
07/16/2015$650K—— → —$112/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHON ENGINEERING806/23/2026
BANGASH ASSOCIATES INC.111/12/2024
ASR ENGINEERING PC106/27/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ABC PERMIT EXPEDITING403/21/2026
CHON ENGINEERING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RED HILL RESTORATION CORPGeneral Contractor607/08/2026
ALL-RITE ELECT CORP OF NYElectrical103/22/2026
JODOM MECHANICAL, INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHON ENGINEERING PC2454405/28/2026
BANGASH ASSOCIATES INC8488111/12/2024
Building Lifecycle
All (60)Filed (10)Permit Issued (5)Signed Off (1)Violation (10)Inspection (5)Objection (2)Special Inspection (27)
08/03/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/29/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/14/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/23/2026
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-P5
06/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/05/2026
Permit issued — Plumbing
X01261673-S1-PL
05/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
05/29/2026
Special inspection requirement — Final
Steve Chon
05/29/2026
Special inspection requirement — Fire-Resistance Rated Construction
Steve Chon
05/29/2026
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
05/29/2026
Special inspection requirement — HVAC-R and service water heating equipment
Steve Chon
05/29/2026
Special inspection requirement — Mechanical Systems
Steve Chon
05/28/2026
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-P4
05/27/2026
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-P3
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
05/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Steve Chon
05/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
Steve Chon
05/27/2026
Special inspection requirement — Final
Steve Chon
05/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
05/27/2026
Special inspection requirement — Mechanical Systems
Steve Chon
05/22/2026
Filed — Alteration
INSTALL NEW HOOD, EXHAUT FAN
X01406074-I1
05/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
05/21/2026
Special inspection requirement — Final
05/21/2026
Special inspection requirement — Fire-Resistance Rated Construction
Steve Chon
05/21/2026
Special inspection requirement — Mechanical Systems
05/20/2026
Objection resolved — Addressed
05/19/2026
Objection raised — Cost
05/18/2026
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-P2
05/15/2026
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-P1
05/14/2026
Special inspection requirement — HVAC-R and service water heating equipment
Steve Chon
05/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
05/14/2026
Special inspection requirement — Mechanical Systems
Steve Chon
05/14/2026
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
05/14/2026
Special inspection requirement — Final
Steve Chon
05/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
Steve Chon
02/05/2026
Signed off — Alteration
INSTALLATION OF PLYWOOD CONSTRUCTION FENCE TO ENCLOSE FIRE DAMAGES PROPERTY.
X01070638-I1
10/21/2025
Permit issued — General Construction
X01261673-I1-GC
07/29/2025
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-I1
07/29/2025
Filed — Alteration
INTERIOR ALERTATION OF EXISTING 1 STORY COMM. BUILDING. REPLACE EXISTING STORE FRONT. REAPAIR EXISTING EXTERIOR BRICK WALL. INSTALL NEW SPLIT SYSTEMS.
X01261673-S1
07/14/2025
Permit issued — Construction Fence
X01070638-I1-FN
06/05/2025
Violation issued (ECB, open)
Construction
06/05/2025
Violation issued (ECB, open)
Construction
11/14/2024
Permit issued — General Construction
X01120925-I1-GC
11/12/2024
Filed — Alteration
REPLACE ENTIRE ROOF, ROOF JOISTS, (DAMAGED DURING FIRE FIGHTING OPERATION), NEW CEILING AND NEW PARAPET WALL,
X01120925-I1
11/08/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAZAL BANGASH
11/08/2024
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
11/08/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAZAL BANGASH
11/08/2024
Special inspection requirement — Masonry
FAZAL BANGASH
10/02/2024
Special inspection requirement — Final
FAZAL BANGASH
07/05/2024
Permit issued — Construction Fence
X01070638-I1-FN
06/27/2024
Filed — Alteration
INSTALLATION OF PLYWOOD CONSTRUCTION FENCE TO ENCLOSE FIRE DAMAGES PROPERTY.
X01070638-I1
06/12/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/21/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/21/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/03/2007
Violation issued (ECB, closed)
Construction
09/04/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/04/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/04/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/04/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJODOM MECHANICAL, INC06/05/2026
DOB NOWGeneral ConstructionPermit IssuedRED HILL RESTORATION CORP10/21/2025
DOB NOWConstruction FenceSigned-offRED HILL RESTORATION CORP07/14/2025
DOB NOWGeneral ConstructionPermit IssuedRED HILL RESTORATION CORP11/14/2024
DOB NOWConstruction FenceSigned-offRED HILL RESTORATION CORP07/05/2024
1 project · most recent 06/23/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/23/2026Permit IssuedRED HILL RESTORATION CORPHeating and Air Conditioning Systems
Heat / Cool
Ct-Morley MOU-A33H-2 33,000 BTU · Condensing Unit ×3
MIU-A33HW-2 33,000 BTU · Split System ×2
MIU-A36W-2 36,000 BTU · Condensing Unit ×2
MIU-A24GW-2 24,000 BTU · Split System ×1
MOU-A24G-2 24,000 BTU · Condensing Unit ×1
MOU-A36H-2 36,000 BTU · Condensing Unit ×1
8 projects · most recent 07/30/2026
General Wiring
FiledStatusContractorScope
07/30/2026CompleteALL-RITE ELECT CORP OF NY5 meters, 1 new_meters
07/12/2026Permit IssuedDREAM TEAM ELEC'L CORPGeneral Wiring
07/12/2026Permit IssuedDREAM TEAM ELEC'L CORPGeneral Wiring
07/12/2026Permit IssuedDREAM TEAM ELEC'L CORPGeneral Wiring
07/08/2026Permit IssuedDREAM TEAM ELEC'L CORPGeneral Wiring
06/07/2025Permit IssuedDREAM TEAM ELEC'L CORPGeneral Wiring
05/23/2024Permit IssuedALL WAYS ELECTRIC CORP.W—
09/04/2019Permit IssuedAPPROVED ELECTRIC CORP.8 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/03/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/29/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/14/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/14/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
05/29/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
05/29/2026FinalSteve Chonprogress
05/29/2026Fire-Resistance Rated ConstructionSteve Chonprogress
05/29/2026Energy Code Compliance InspectionsSteve Chonprogress
05/29/2026HVAC-R and service water heating equipmentSteve Chonenergy_progress
05/29/2026Mechanical SystemsSteve Chonspecial
05/27/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
05/27/2026HVAC-R and service water heating equipmentSteve Chonenergy_progress
05/27/2026Fire-Resistance Rated ConstructionSteve Chonprogress
05/27/2026FinalSteve Chonprogress
05/27/2026Energy Code Compliance InspectionsSteve Chonprogress
05/27/2026Mechanical SystemsSteve Chonspecial
05/21/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
05/21/2026Final—progress
05/21/2026Fire-Resistance Rated ConstructionSteve Chonprogress
05/21/2026Mechanical Systems—special
05/14/2026HVAC-R and service water heating equipmentSteve Chonenergy_progress
05/14/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
05/14/2026Mechanical SystemsSteve Chonspecial
05/14/2026Energy Code Compliance InspectionsSteve Chonprogress
05/14/2026FinalSteve Chonprogress
05/14/2026Fire-Resistance Rated ConstructionSteve Chonprogress
11/08/2024Fire-Resistance Rated ConstructionFAZAL BANGASHprogress
11/08/2024Energy Code Compliance InspectionsFAZAL BANGASHprogress
11/08/2024Structural Stability – Alterations of existing buildingsFAZAL BANGASHspecial
Latest 25 of 27.
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/21/2026X01070638-I1Request digital key ↗
08/20/2026X01120925-I1Request digital key ↗
08/16/2026X01406074-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature13
09/02/2026X01261673-P4Open ↗
09/02/2026X01261673-P4Open ↗
09/02/2026X01120925-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/21/2026X01070638-I1Open ↗
08/16/2026X01406074-I1Open ↗
08/16/2026X01261673-P5Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/02/2026X01120925-I1Open ↗
09/02/2026X01261673-P4Open ↗
09/02/2026X01261673-P4Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/16/2026X01406074-I1Open ↗
08/16/2026X01261673-P5Open ↗
08/16/2026X01261673-P4Open ↗
Showing 3 of 9 on file for this type