ECB07/21/2026CLASS 1: EXCESSIVE OIL LEAKAGE FROM THE DRIVING MACHINE HAS CONTAMINATED THE HOISTWAY SELECTOR VANES AND ASSOCIATED EQUIPMENT. DRIVING MACHINE BRAKE LINING IS WORN WITH EXCESSIVE BRAKE DUST ACCUMULATION THROUGH$1K due
ECB04/17/2026CLASS 1 CEASE USE: DOOR ZONE RESTRICTOR DEFECTIVE. CODE: ASME A17.1/CSA B44 SEC. 2.12.5. REMEDY: REPAIR/REPLACE AND VERIFY OPERATION. CONTROLLER FUSE BYPASSED. CODE: ASME A17.1/CSA B44 SEC. 8.6.1.2.2. REMEDY: R$1K due
ECB04/23/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED PARTITION WALL LEANING INWARD TOWARDS BUILDING AT ROOF LEVEL. ALSO HAS A 3 FOOT CRACK ON TOP OF 6TH FLOOR WINDOW. POTENTIAL HAZARDS., REPAIR AND/R$1K due
DOB01/22/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB08/30/2024AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A OCCUPIED 6 STORY BUILDING. UPON REVIEWING DEPARTMENT OF BUILDING RECORDS I NOTICED THAT PERMIT IS EXPIRED SINCE 2020 AND NO RENEWED PERMIT WAS SUBMITTED.$1K due
ECB05/27/2024FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #907733. REMEDY: SUBMIT ACCEPTABLE REQU$1K due
DOB02/22/2023FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
DOB03/31/2008V-DOB VIOLATION - ACTIVE
ECB01/15/2026I FOUND A H.B. SMITH 28 8 BOILER WERE THE DOMESTIC HOT WATER WAS GOING UP 200 DEGREES ON THE TEMPERATURE GAUGE/WATER IS TO HOT/ CORRECT ALL VIOLATING CONDITIONS/ SUBMIT A CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB04/23/2025EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., REPAIR/REPLACE DOORNothing owed — awaiting certificate of correction
ECB04/22/2025CLASS 2 ITEM: COMMUNICATION IN CAR INOPERATIVE. REPLACE WORN COUNTER WEIGHT ROLLERS AS NEEDED. ADJUST CAR DOOR TO PROPERLY OPEN AND CLOSE. ADJUST BOTTOM BASEMENT HOISTWY DOOR. CLEAN OIL FROM MACHINE ROOM FLOORNothing owed — awaiting certificate of correction
ECB11/25/2024CEASE USE ITEMS: 1)INOPERATIVE ZONE LOCK RESTRICTOR. 2) RIGHT BRAKE PIN WALKING OUT. 125% BRAKE TEST AND SEALING AND TAGGING OF ALL ADJUSTMENTS REQUIRED AT TIME OF REINSPECTION. CLASS 2 ITEMS: PROVIDE DESIGNATENothing owed — awaiting certificate of correction
ECB08/09/2022I OBSERVED IN THE ELEVATOR MOTOR SWITCH THE IMPROPER FUSING OF THE CONDUCTORS, THE #4 CONDUCTORS HAVE AN AMPACITY LESS THAN THE 100 AMP FUSES THAT ARE INSTALLED AS THE OVERCURRENT PROTECTION OF THE CONDUCTORS.,Nothing owed — awaiting certificate of correction
ECB08/09/2022I OBSERVED UNDER THE SIDEWALK SHED AND ON THE SECOND FLOOR THE POWER SUPPLY FOR THE LIGHTS NOT MECHANICALLY CONNECTED TO THE JUNCTION BOX WITH THE CONDUCTORS EXPOSED AND ENERGIZED. FAILURE TO CONNECT THE RACEWANothing owed — awaiting certificate of correction
ECB08/09/2022I OBSERVED THE RACEWAY AND JUNCTION BOXES/LIGHTS FOR THE SIDEWALK SHED NOT CONNECTED OR SECURED PROPERLY AND WITHOUT PROPER GROUNDING AS REQUIRED., COMPLY WITH EC; PROVIDE PROPER GROUNDING AND GFCI PROTECTION.Nothing owed — awaiting certificate of correction
ECB08/09/2022I OBSERVED IN A BASEMENT STORAGE ROOM ALONG THE 164TH STREET SIDE AN ELECTRICAL PANEL MADE INACCESSIBLE BY SHELVING AND SUPPLIES. ALL ELECTRICAL PANELS SHALL HAVE A CLEARANCE FOR ACCESS IN CASE OF NORMAL OR EMENothing owed — awaiting certificate of correction
ECB08/09/2022I OBSERVED ON THE FIRST FLOOR IN A REAR STORAGE AREA A BATHROOM AND IN THE BASEMENT NEAR THE BOILER ROOM A CONVENIENCE OUTLET NOT OF THE GFCI TYPE AS REQUIRED WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTIONNothing owed — awaiting certificate of correction
ECB08/09/2022FOUND EXPOSED WIRES, DIRTY GLASS GAUGE, OIL LEAK ON OIL LINE AT BURNER, CORRODED WATER PIPE ABOVE BURNER, CLEAN OUT DOORS ON SIDE OF BOILER NEED TO BE RESEALED, BODY DRAIN MISSING ON SAFETY RELIEF VALVE.Nothing owed — awaiting certificate of correction
ECB06/14/2022FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION(SIDEWALK SHED) PERMIT TO REMAIN INSTALL AND USE OF TEMP EQUIPMENT. OBSERVED SWS ERECTED AT EXPOSURE#1&4. DID NOT FIND ACTIVE PERMIT IN BIS AND DOB NOW. PERMIT IN DOB NNothing owed — awaiting certificate of correction
ECB04/29/2022FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED:AT CELLAR LEVEL,CEILING/WALLS,OPENING WERE CREATED EXPOSING,REBARS & METALLIC STRUCTURE TO SUPPORT 1ST FL SLAB STRUCTURE.REMEDY:REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB04/29/2022EXIT DOOR NOT SELF CLOSING.OBSERVED:FIRE PROOF SELF-CLOSING DOOR,FROM 6TH FL TO 1ST FL,NEAR ROOMS #40 & CELLAR LEVEL.INTERIOR EXIT DOOR DO NOT ALLOW EASY ESCAPE FROM THE BLDG DOORS DO NOT MEET TECHNICAL & SAFENothing owed — awaiting certificate of correction
ECB04/29/2022FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.OBSERVED:AT ROOF LEVEL,PARAPET WALLS,CRACKED ON 2 SIDES,FACADE & INTERIOR SIDE. REMEDY:MAINTAIN EXTERIOR BLDG WALL.Nothing owed — awaiting certificate of correction
ECB04/29/2022WORK W/OUT A PERMIT.OBSERVED:AT CELLAR LEVEL,FIRE ALARM ROOM,A WALL WAS BUILT IN CMU BLOCKS,CREATING AN ADDITIONAL ROOM.ALSO,METAL STRUCTURE(BEAMS/COLUMNS)WAS INSTALLED TO SUPPORT PART OF THE 1ST FL SLAB.ACTIVINothing owed — awaiting certificate of correction
ECB04/29/2022FAILURE TO MAINTAIN BLDG N CODE COMPLIANT MANNER.OBSERVED:AT ROOF LEVEL,WATERPROOFING MANTLE OR MEMBRANE SHOWS MATERIAL LIFTING FAILURES,CRACKS,OPENINGS IN ENTIRE ROOF AREA.REMEDY:REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/30/2021FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:OBSEREVED HORIZONTAL AND VERTICAL CRACKS AT ROOF'S PARAPET WALL (ROOF SIDE)AT VARIOUS LOCATIONS.REMEDY:MAINTAIN EXTERIOR BUILDING WALL.Nothing owed — awaiting certificate of correction
ECB11/21/2019NOTED: OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY ##8081, ENTIRE FIRST FLOOR OCCUPIED AS OFFICES AND COPY ROOM OVER THE ALLOWABLE 10% FOR ACCESSORY OCCUPANCIES AS PER BC 508, 508.2.1 , DISCONTINUE ILLEGAL ONothing owed — awaiting certificate of correction
ECB11/21/2019NOTED: OBSERVED HORIZONTAL AND VERTICAL CRACKS THROUGHOUT PARAPET WALL EXPOSURE #3,#4 AND VARIOUS LOCATIONS THROUGHOUT PARAPET. , MAINTAIN EXTERIOR BUILDING WALLNothing owed — awaiting certificate of correction
ECB11/21/2019I OBSERVED THROUGHOUT THE HALLWAYS ON EVERY FLOOR, LIGHT FIXTURES THAT ARE NOT PROPERLY CONNECTED ( NO MECHANICAL CONNECTION BETWEEN CONDUIT/CABLE AND ELECTRICAL BOX/FIXTURE) EXPOSED ENERGIZED CONDUCTORS @ THENothing owed — awaiting certificate of correction
ECB05/13/2019FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC1006.1;27-381. NOTED: EXISTING EMERGENCY LIGHT PACKAGES WERE NOT OPERATIONAL WHEN TESTED AT 6THNothing owed — awaiting certificate of correction
ECB02/09/2018FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. AS NOTED: EXPOSURE #1 AND 4 CRACKS AT PARAPET LEVEL, SPALLED BRICKS, CRACKED STONES, SPALLED STONES ALL EXPOSURES, EXPOSURE 4 CRACKS IN STORE GROUNothing owed — awaiting certificate of correction
ECB10/03/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT ALL STORY CORRIDORS,EMERGENCY EXIT LIGHTS NOT WORKINNothing owed — awaiting certificate of correction
ECB10/03/2017FAILURE TO MAINTAIN BUIDING IN CODE COMPLIANT MANNER .RE:INSTALLATION MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PC 102.3;27-902. OBSERVED ON 10/3/17 AT ABOVE ADDRESS PVC IPING THROUGH OUT BASEMENT /CELLARNothing owed — awaiting certificate of correction
ECB10/03/2017UNAPPROVED /UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS DEVICE,APPLIANCE,OR WIRING IN USE.OBSERVED IN BASEMENT AREA STORAGE ROOM AND IMPROPERLY CONNECTED LIGHTS,THE USE OF BAR COPPER CONDUCTORSNothing owed — awaiting certificate of correction
ECB10/03/2017ELECTRICAL WORK DOES NOT CONFORM TO SUBMITTED APPROVED DOCUMENTS.OBSERVED NEW 1ED TYPE EMERGENCY LIGHTS THROUGHOUT BUILDING HALLWASYS APPLICATION #152220 COVERS INSTALLATION OF 13 ADDITIONAL EMERGENCY LIGHTS NONothing owed — awaiting certificate of correction
ECB08/15/2017OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTED: ACCORDING TO C OF O#8081 THE 1ST FL SHOULD BE 10 BEDROOMS UTILITY ROOM,STORES,& RESTAURANT. THE ENTIRE 1ST FL IS NOW OFFICES.Nothing owed — awaiting certificate of correction
ECB03/17/2016FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES-NOTED AT TIME OF INSPECTION,PREVIOUS VIOLATED CONDITIONS AT EXPOSURE 1(CRACKED PARAPET)& AT EXPOSURE 4(E 164 ST.)-(I)DANGLING MIS. ANGLE PIECE BY 2/F WINDOWNothing owed — awaiting certificate of correction
ECB01/27/2016FAILURE TO MAINTAIN EXTERIOR BLG AS NOTED: AT TIME OF INSPECTION OBSERVED, 1-WEST LOCATION (PROSPECT AV)EXP#1 & 4 (EAST 164 ST) COPING BROKEN/CHIPPED IN VARIOUS AREAS; (II) METAL PC HANGING AT SOUTHWEST CORNER;Nothing owed — awaiting certificate of correction
ECB08/31/2015FAILURE TO MAINTAIN EXTERIOR BUILDING. EXP1 AND EXP4 ORNAMENTAL FACADEAPPEARS WORN AND HOLLOWED OUT AT EXP1 PARAPET EDGE ON ROOF HAS VISIBLECRACKS.HANGING PC OF METAL AT CORNER OF BUILDING ON FLR 2 MISSING MASONothing owed — awaiting certificate of correction
ECB09/12/2012FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVATION, EXP 3 OBSERVE BROKENOFF, DETERIORATING AND MISSING MASONRY FACADE UNITS, DETERIORATING, DISPLACEMENT AND LOOSE IN STEEL PLATE, VERTICAL CRACKS & DISPLACEMENT INNothing owed — awaiting certificate of correction
ECB06/16/2010FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE / STORAGE BATTERY EQUIPMENT. REMEDY: FILE ARCHITECT / ENGINEER REPORT.Nothing owed — awaiting certificate of correction
ECB05/21/2008B4A32A50A50B. 50A HOLES IN WALLS AND CEILING. 50B DEBRIS IN BOILER ROOM.Nothing owed — awaiting certificate of correction
ECB10/19/1995FAILURE TO MAINTAIN THE INTERIOR FLOORS.THE SOUTHEAST WING OF THE 2-6 FLOORS SAG BY APPROX. 2-3 INCHES.REMEDY:OTHER PERMITS AND MAKE THE NECESSARY REPAIRS.Nothing owed — awaiting certificate of correction
ECB04/07/1995FAILURE TO MAINTAIN. DEFECT IS HALLWAY FLOOR SAGGING FROM 2ND FLOOR THRU 6TH FLOOR. REMEDY: MAKE ALL REPAIRS AND REQUEST ENGINE REPORT ON STABILITY.Nothing owed — awaiting certificate of correction
ECB03/28/1995FAILURE TO MAINTAIN BUILDING DEFECT IS FLOOR LEANING DEFECTIVE THROUGHOUT 4 AND 5 FLOOR PUBLIC HALL SIGNLE ROOMS REMEDY FILE PLANS OBTAIN APPROVAL AND PERMIT NOTE SUBMIT ENGINESSES REPORT FOR STRUCTURAL STABILYNothing owed — awaiting certificate of correction
ECB01/14/1992DUE TO FIRE OF UNDETERMINED ORIGIN ABOVE PREMISES HAS SUSTAINED FIRE DAMAGE TO ROOF BEAMS AND INTERIOR PARTITIONS AT THE NORTHWEST AND NORTHEAST SECTION. REMEDY: OBTAIN PERMIT AND MAKE ALL NECESSARY REPAIRNothing owed — awaiting certificate of correction
ECB01/04/1989WORK CONTRARY TO APPROVED PLANS WORK NOTED: SKYLIGHT NOT PROVIDED OVER ROOF BULKHEAD AS SHOWN ON APPROVED PLAN. REMEDY: CONFORM TO SAID APPROVED PLAN. PROVIDE SKYLIGHT ABOVE ROOF BULKHEAD.Nothing owed — awaiting certificate of correction