← Back
Two family brick
982 EAST 37 STREET
BROOKLYN · East Flatbush-Farragut · BIN 3206160
💬 Discuss this project
1915Year Built
2Stories
B1Building Class
R4Zoning
2,136 sfGross Floor Area
2Units
Two family brick · 2,000 sf lot · 1.07 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 22p · 2 filings · 6 docs
Floor 12p · 2 filings · 6 docs
Cellar2p · 2 filings · 6 docs
Site & exterior1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ELITE PROPERTIES NYC903/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/11/2024$1.2M—ELITE PROPERTIES NYC HOMES LLC → Private party$545/sf building
12/02/2022$650K—Private party → ELITE PROPERTIES NYC HOMES LLC$304/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
XC ENGINEERING PC205/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
G DESIGN DRAFTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XINLI.CONSTRUCTION LLCGeneral Contractor303/21/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
XC ENGINEERING PC6692105/24/2023
Building Lifecycle
All (12)Filed (2)Permit Issued (2)Signed Off (2)Inspection (6)
07/03/2023
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH INTERIOR RENOVATION OF (2) FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00872645-I1
06/30/2023
Signed off — Alteration
INTERIOR RENOVATION OF (2) FAMILY HOUSE WITH MECHANICALWORK. PLUMBING WORK WILL BE FILED SEPARATELY. NO CHANGEIN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00872644-I1
06/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/26/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/23/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/20/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/09/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/26/2023
Permit issued — Plumbing
B00872645-I1-PL
05/25/2023
Permit issued — Mechanical Systems
B00872644-I1-GC-CX
05/24/2023
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH INTERIOR RENOVATION OF (2) FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00872645-I1
05/24/2023
Filed — Alteration
INTERIOR RENOVATION OF (2) FAMILY HOUSE WITH MECHANICALWORK. PLUMBING WORK WILL BE FILED SEPARATELY. NO CHANGEIN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00872644-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN05/26/2023
DOB NOWMechanical SystemsSigned-offXINLI.CONSTRUCTION LLC05/25/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/26/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/23/2023Pass-Final General Construction Non-Directive 14PassView ↗
06/20/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/09/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026B00872644-I1Request digital key ↗
08/27/2026B00872645-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026B00872644-I1Open ↗
08/27/2026B00872645-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026B00872644-I1Open ↗
08/27/2026B00872645-I1Open ↗