HPD07/12/2023§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD07/12/2023§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY
HPD07/12/2023§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
HPD07/12/2023§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AROUND SCUTTLE LADDER AT PUBLIC HALL, 3rd STORY
HPD07/12/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL ABOVE WINDOW FRAME IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL ABOVE WINDOW FRAME IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/12/2023§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
HPD07/12/2023§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD07/12/2023§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY
HPD12/08/2022HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2022§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQUARE FOOT AT WINDOW STOOL ,EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 15602151 ISSUED 08-DEC-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD12/08/2022§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2022§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WINDOW STOOL AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2022§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING 130 DEGREES FARENHEIT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/17/2013§ 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 3, 3rd STORY
HPD12/17/2013§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK LOCATED AT METAL SECURITY DOOR AT ENTRANCE TO THE BUILDING AT PUBLIC HALL, 1st STORY
HPD12/17/2013§ 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
HPD04/22/2013§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE SKYLIGHT AT CEILING IN THE BATHROOM LOCATED AT APT 3, 3rd STORY
HPD04/22/2013§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY
HPD04/22/2013§ 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY
HPD04/22/2013§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY
DOB01/02/2013FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD03/23/2011§ 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2NDFL, 2nd STORY
HPD03/23/2011§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY
DOB02/23/2011FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/15/2010FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD08/09/2010§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY
HPD08/09/2010§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY
HPD08/09/2010§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING IN THE 1st LIVING ROOM FROM EAST AT SOUTH LOCATED AT APT 3FL, 3rd STORY
HPD10/30/2008§ 27-2091 HMC, § 302 MDL : APARTMENTS HAVE BEEN ISSUED A COMMISSIONER'S ORDER AND OCCUPANTS ARE IN NEED OF RELOCATION SERVICES. APARTMENTS CANNOT BE RE-OCCUPIED UNITL THE COMMISSIONER'S ORDER IS REVOKED AFTER HPD INSPECTION OF APARTMENTS. COMMISSIONERS ORDER # 08/0144 IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY
ECB06/23/2016FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN NOV# 34875836N ISSUED ON 9/17/10 & TO FILE A C OF C PURSUANT TO 28-201.1, 28-204.4 & 1RCNY 102-01. WORK W/OUT A PERMIT. @ 1ST FLR LEVEL INSTALLED WATERNothing owed — awaiting certificate of correction
ECB04/13/2015FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #34875836N ISSUED ON 09/17/10 FOR WORK W/O PERMIT. RMDY: COMPLY WITH THE COMMISSIONER'S ORDER.Nothing owed — awaiting certificate of correction
ECB02/27/2015FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10,FOR WORK W/O PERMITS 1FL GAS & PLUMBING LINES. REMEDY: COMPLY W/THE COMM'S ORDER.Nothing owed — awaiting certificate of correction
ECB01/06/2015FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 09/17/10 FOR WORK W/O PERMIT-1FL GAS AND PLUMBING LINES.REM:COMPLY WITH THE COMMISSIONER'S ORDER.Nothing owed — awaiting certificate of correction
ECB11/07/2014FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10,FOR WORK W/O PERMIT - 1FL GAS & PLUMBING LINES,REMOVAL OF GARAGE DOOR & REPLACED W/PARTITION.Nothing owed — awaiting certificate of correction
ECB09/05/2014FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINE DIN NOTICE OF VIOLATION#34875836N ISSUED ON 09/17/10,FOR WORK W/O PERMIT-1FL.GAS & PLUMBING LINES,REMOVE OF GARAGE DOOR & REPLACED W/ PARTITION.REM:COMPLY W/ THE CNothing owed — awaiting certificate of correction
ECB07/31/2014FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10,FOR WORK W/O PERMIT - 1FL GAS & PLUMBING LINES,REMOVAL OF GARAGE DOOR & REPLACES W/PARTITIONS.Nothing owed — awaiting certificate of correction
ECB06/11/2014FAIL TO COPMLY W/THE COMM'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10,FOR WORK W/O PERMIT 1FC.GAS & PLUMB LINES,REMOVAL OF GARBAGE DOWN & REPLACED W/PARTITION.REM:COMPLY W/THE COMM'S ONothing owed — awaiting certificate of correction
ECB04/01/2014FAIL TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #34875836N ISSUED 9/17/10 FOR WORK W/O PERMIT-1 FL. GAS & PLUMBING LINES, REMOVAL OF GARAGE DOOR & REPLACE W/PARTITION.REM:COMPLY W/COMMISSIONER'S ORDER.Nothing owed — awaiting certificate of correction
ECB10/15/2013FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C OF C W/THE DEPT OF BUILDINGS FOR NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10 PURSUANT TO 28-204.4 & 1RCNY 102-01. REMEDY: FILE A C OF C.Nothing owed — awaiting certificate of correction
ECB10/15/2013FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34875836N ISSUED ON 9/17/10. WORK W/O PERMIT FOR 1ST FL & GARAGE. NO PERMITS HAVE BEEN ISSUED TO REMEDY. THE RESPONDENT HAS A HISTONothing owed — awaiting certificate of correction
ECB08/27/2013FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #34875836N ISSUED ON 9/17/10 FOR PLUMBING & GAS WORK WITHOUT A PERMIT. RMDY: COMPLY W/COMMISSIONER'S ORDER.Nothing owed — awaiting certificate of correction
ECB09/01/2012FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV #34875836N ISSUED ON 9.17.10 FOR ILLEGAL PLUMBING, GAS LINES ALSO REMOVAL OF GARAGE DOOR. REMEDY: COMPLY W/THE COMMISSIONER'S ORDER.Nothing owed — awaiting certificate of correction
ECB08/30/2012UNLAWFUL ACTS.FAILURE TO COMPLY W/ AN ORDER OF THE COMMS VACATE ORDER Q798/10 FOR GARAGE AREA ON GROUND FLR NOT BEING COMPLETED @ TIME OF INSPECTION.1 MALE TENANT OCCUPYING PREMISES.REM:COMPLY W/ THE COMMS ORDENothing owed — awaiting certificate of correction
ECB08/30/201228-201.1;28-203.1:FAILURE TO COMPLY WITH VACATE ORDER#Q798/10 ISSUED ON 9/17/10. NOTED ILLEGAL OCCUPANCY AT FIRST FLR STILL EXIST. REM:COMPLY WITH VACATE ORDER.Nothing owed — awaiting certificate of correction
ECB05/12/2011UNLAWFUL ACTS.FAILURE TO COMPLY W/ AN ORDER OF THE COMMISSIONER.RESPONDENT FAILED TO VACATE 1ST FLR GARAGE & REC ROOM PER VACATE ORDER#Q798/10 ILLEGALLY CONVERTED TO A CLASS A APT VACATED SPACE HAS BEEN RE-OCCUNothing owed — awaiting certificate of correction
ECB09/17/2010RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILY. COQ #141263 INDICATES PREMISES TO BE LEGALLY APPROVED FOR A 2 FAMILY WITH 1ST FL AS RECREATION ROOM,BOILER ROOM &Nothing owed — awaiting certificate of correction
ECB09/17/2010OCCUPANCY CONTRARY TO THAT ALLOWED BY DEPT OF BLDG RECORDS. COQ #141263 INDICATES PREMISES TO BE LEGALLY APPROVED FOR A 2 FAMILY W/1ST FL ASRECREATIONAL ROOM,BOILER ROOM & GARAGE ILLEGAL OCCUPANCY NOTED: GARAGENothing owed — awaiting certificate of correction
ECB09/17/2010WORK W/O A PERMIT. WORK NOTED AS FOLLOWS: AT 1ST FL LEVEL (1) INSTALLED WATER & WASTE LINE FOR SHOWER & RESIDENTIAL SINK (2) ALSO INSTALLED GAS LINE FOR STOVE. (3) GARAGE DOOR REMOVED & REPLACED BY FULL HEIGHTNothing owed — awaiting certificate of correction
Three families · Owner of record: 225 WEST CORP · 1,755 sf lot · 1.38 FAR built · Flood zone X