← Back
Two stories - detached, small or mid-size
99-51 RUSSELL STREET
QUEENS · Howard Beach-Lindenwood · BIN 4296256
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R3AZoning
2,327 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Two stories - detached, small or mid-size · 4,152 sf lot · 0.56 FAR built · Flood zone VE
Locations of Work
Electrical
Roof1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/28/2021$760K—Private party → Private party$327/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC102/27/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYS ESSENTIAL POWER INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854102/27/2025
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Signed Off (1)Violation (5)Special Inspection (5)
05/16/2025
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01187290-I1
03/03/2025
Permit issued — Solar
Q01187290-I1-SL
02/27/2025
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01187290-I1
02/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/26/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/26/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
02/26/2025
Special inspection requirement — Final
TOM PETERSEN
02/26/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
10/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/11/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/17/2007
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
11/13/2002
Violation issued (ECB, closed)
Construction
08/08/1988
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYS ESSENTIAL POWER INC03/03/2025
BISPLISSUEDVINCESKI MAY PLB & HTG LL08/15/2011
BIS—ISSUEDTIMBER RIDGE FRAMING CORP07/25/2011
BISPLISSUEDCATMAN PLUMBING INC02/28/2008
BIS—ISSUEDN/A02/05/2008
BIS—ISSUEDTIMBER RIDGE FRAMING10/23/2007
BIS—ISSUEDTIMBER RIDGE FRAMING10/18/2007
1 project · most recent 04/29/2025
FiledStatusContractorScope
04/29/2025CompleteAMBER ELECTL CONTNG INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
02/26/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/26/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/26/2025Energy Code Compliance InspectionsTOM PETERSENprogress
02/26/2025FinalTOM PETERSENprogress
02/26/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01187290-I1Request digital key ↗
▸Applications & Permits3
▸BISRescission of Intent to Revoke Approval/Permit1
07/13/2011402495661Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
04/04/2016402495661Open ↗
▸BISIntent to Revoke Approval/Permit1
01/16/2014402495661Open ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01187290-I1Open ↗
08/25/2026Q01187290-I1Open ↗
08/25/2026Q01187290-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01187290-I1Open ↗
08/25/2026Q01187290-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01187290-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01187290-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01187290-I1Open ↗