← Back
BROOKLYN
990 LINCOLN AVENUE
BROOKLYN · East New York-City Line · BIN 3855646
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
Filed — no permit issued1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MJ AFFORDABLE DEVELOPMENT, LLC403/21/2026
SHELTER ROCK BUILDERS109/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AUTOMATED DESIGN ENGINEERING, PLLC103/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AUTOMATED DESIGN CONSULTA895103/25/2026
Building Lifecycle
All (9)Filed (1)Special Inspection (8)
03/25/2026
Filed — Alteration
Install mechanical system in conjunction with GC (-I1) NB filing B01354779-I1. There is no change in use, occupancy, or egress.
B01377661-I1
03/25/2026
Special inspection requirement — HVAC-R and service water heating system controls
Gregory Mortman
03/25/2026
Special inspection requirement — Energy Code Compliance Inspections
Gregory Mortman
03/25/2026
Special inspection requirement — Ventilation and air distribution system
Gregory Mortman
03/25/2026
Special inspection requirement — HVAC-R and service water heating equipment
Gregory Mortman
03/25/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Gregory Mortman
03/25/2026
Special inspection requirement — Shutoff dampers
Gregory Mortman
03/24/2026
Special inspection requirement — Final
Gregory Mortman
03/24/2026
Special inspection requirement — Mechanical Systems
Gregory Mortman
Nothing on file for this building.
1 project · most recent 03/25/2026
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/25/2026——Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Fujitsu ASUA007KSA2 7,500 BTU · Vrf Indoor ×144
AOUK036SSAN7 42,000 BTU · Heat Pump Outdoor ×126
ASUA004KSA2 4,000 BTU · Vrf Indoor ×63
ASUA014KSA2 14,000 BTU · Vrf Indoor ×63
Heating
Cadet CEC163TW 5,115 BTU · Electric Heater ×63
Ventilation
Panasonic FV-0511VFL1 50 CFM · Exhaust Fan ×126
Fantech FIT 120E-D-EC-HC 50 CFM · Erv ×63
FG4XL EC 50 CFM · Exhaust Fan ×21
Broan Series 423001 150 CFM · Kitchen Exhaust ×63
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
03/25/2026HVAC-R and service water heating system controlsGregory Mortmanenergy_progress
03/25/2026Energy Code Compliance InspectionsGregory Mortmanprogress
03/25/2026Ventilation and air distribution systemGregory Mortmanenergy_progress
03/25/2026HVAC-R and service water heating equipmentGregory Mortmanenergy_progress
03/25/2026HVAC-R and service water piping design and insulationGregory Mortmanenergy_progress
03/25/2026Shutoff dampersGregory Mortmanenergy_progress
03/24/2026FinalGregory Mortmanprogress
03/24/2026Mechanical SystemsGregory Mortmanspecial
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026B01377661-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
06/22/2009320037857Open ↗
06/22/2009320037857Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
07/02/2009320037857Open ↗
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED1
07/02/2009320037857Open ↗
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
07/02/2009320037857Open ↗
▸Seals & Professional Certifications8
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
06/22/2009320037857Open ↗
06/22/2009320037857Open ↗
06/22/2009320037857Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026B01377661-I1Open ↗
08/28/2026B01377661-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026B01377661-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B01377661-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
06/22/2009320037857Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
06/22/2009320037857Open ↗
▸Inspections & Test Reports1
▸BISHYDRO FLOW TEST LETTER1
07/02/2009320037857Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
06/22/2009320037857Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
06/22/2009320037857Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
06/22/2009320037857Open ↗
06/22/2009320037857Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
06/22/2009320037857Open ↗