ECB02/25/2026FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATION #39135196M., FILE A CERTIFICATE OF CORRECTION$6K due
ECB02/25/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER FOR VIOLATION # 39135192P .NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 2022 CODE). NO FIRESTOPPING OBSERVED AROUND CABLES COMING THROUGH P$25K due
ECB02/13/2025FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39097339X ISSUED ON 10/18/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT$6K due
ECB01/10/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETERATIONS IN JANITOR ROOM ON 3RD FLOOR, ELECTRIC ROOM AND IT ON$3K due
ECB01/10/2025I OBSERVED IN THE ELEVATOR MOTOR DISCONNECT THE IMPROPER FUSING OF THE CONDUCTORS, ALL FUSES SHALL BE OF THE SAME AMPERAGE AND TYPE., PROVIDE PROTECTION AGAINST OVERCURRENT; PROPERLY COORDINATE FUSES.$5K due
ECB01/10/2025I OBSERVED IN THE ELEVATOR MOTOR ROOM THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING AS EC 400.8 THIS IS NOT ALLOWED. ALSO NOTED IN THE THIRD FLOOR BATHROOM ON THE "B" SIDE BATHROOM A IMPROPERLY WIRE$800 due
ECB01/10/2025EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOOR AT GAS METER ROOM IN BASEMENT. POTENTIAL FIRE HAZARD., REPAIR/REPLACE DOOR$625 due
ECB10/24/2025@CELLAR AO SMITH HOT WATER HEATER#1 HAS CORRODED SAFETY VALVE PIPE+#3 HWH IS INOPERABLE+ALL HWH'S ARE MISSING CONDENSATE NEUTRALIZER+GAS METER ROOM FRESH AIR HAS BROKEN FIRE DAMPER+OUTSIDE INLET IS MISSING GRATNothing owed — awaiting certificate of correction
ECB10/22/2025OBSERVED ON THE FIRST FLOOR IN THE KITCHEN NO TRAP UNDER SINK WHICH CONTRARY CODE SECTION PC 1002.1, REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB10/18/2023SPRINKLER HEADS ON THE 1ST AND 3RD FLOOR OBSTRUCTED BY CEILING. AS PER 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN ACCORDANCENothing owed — awaiting certificate of correction