| Owner | Filings | Most Recent |
|---|---|---|
| TRIERA CONTRACTING INC | 9 | 03/22/2026 |
| BLUE ELM MANAGEMENT | 3 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| NY BUILDING ASSOCIATES INC | 5 | 02/08/2023 |
| ADVANCED ENGINEERING & INSPECT. PLL | 2 | 09/20/2022 |
| ENTHINK ENGINEERS LLC | 2 | 09/13/2022 |
| BGM ENGINEERING | 2 | 06/01/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| ADVANCED BUILDERS SERVICES | 18 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| BLUE ELM INC | General Contractor | 15 | 07/08/2026 |
| TRIERA CONTRACTING INC | General Contractor | 6 | 03/21/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| PRIME PIPING & HEATING IN | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 8 | 02/08/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | BLUE ELM INC | 01/14/2023 |
| DOB NOW | General Construction | Permit Issued | BLUE ELM INC | 12/28/2022 |
| DOB NOW | Plumbing | Signed-off | A M B MECHANICAL INC | 10/28/2022 |
| DOB NOW | Sprinklers | Signed-off | PRIME PIPING & HEATING IN | 10/28/2022 |
| DOB NOW | Supported Scaffold | Signed-off | TRIERA CONTRACTING INC | 09/16/2022 |
| DOB NOW | Sidewalk Shed | Signed-off | TRIERA CONTRACTING INC | 08/17/2022 |
| DOB NOW | General Construction | Permit Issued | BLUE ELM INC | 08/04/2022 |
| DOB NOW | Structural | Signed-off | BLUE ELM INC | 07/12/2022 |
| DOB NOW | Earth Work | Signed-off | BLUE ELM INC | 06/15/2022 |
| DOB NOW | Earth Work | Signed-off | BLUE ELM INC | 06/03/2022 |
| DOB NOW | Construction Fence | Signed-off | BLUE ELM INC | 05/24/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/08/2023 | Signed-off | BLUE ELM INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MSZ-GL09NA-U1 9,000 BTU · Fan Coil Indoor ×12 MSZ-GL12NA-U1 12,000 BTU · Fan Coil Indoor ×6 MSZ-GL15NA-U1 14,000 BTU · Fan Coil Indoor ×3 Markel E3323TD-RP 5,120 BTU · Electric Heater ×2 Qmark MUH0381 3 kW · Electric Heater ×1 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/08/2023 | Signed-off | PRIME PIPING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/08/2023 | Signed-off | A M B MECHANICAL INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/26/2023 | Complete | SAFEWAY CONSTRUCTION, INC | General Wiring, Lighting |
| 08/29/2022 | Cancelled | SAFEWAY CONSTRUCTION, INC | General Wiring, Lighting |
| 08/11/2022 | Complete | RICHARD NEU | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/06/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/31/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 01/27/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 01/24/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/18/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/04/2023 | Pass-Final House Connection | Pass | View ↗ |
| 11/09/2022 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 11/09/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 11/09/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/09/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/10/2023 | Metering | FAHAD FATEH | energy_progress |
| 02/10/2023 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 02/10/2023 | Maintenance information | FAHAD FATEH | energy_progress |
| 02/10/2023 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 02/10/2023 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 02/10/2023 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 02/10/2023 | Fenestration areas | FAHAD FATEH | energy_progress |
| 02/10/2023 | Exterior lighting power | FAHAD FATEH | energy_progress |
| 02/10/2023 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 02/10/2023 | Lighting controls | FAHAD FATEH | energy_progress |
| 02/10/2023 | Interior lighting power | FAHAD FATEH | energy_progress |
| 02/10/2023 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 02/10/2023 | Sprayed fire-resistant materials | FAHAD FATEH | special |
| 02/10/2023 | Exterior Insulation and Finish Systems (EIFS) | FAHAD FATEH | special |
| 02/10/2023 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 02/10/2023 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 02/08/2023 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 02/08/2023 | Exterior Insulation and Finish Systems (EIFS) | FAHAD FATEH | special |
| 02/08/2023 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 02/08/2023 | Sprayed fire-resistant materials | FAHAD FATEH | special |
| 02/08/2023 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 02/08/2023 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 02/08/2023 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 02/08/2023 | Lighting controls | FAHAD FATEH | energy_progress |
| 02/08/2023 | Lighting in dwelling units | FAHAD FATEH | energy_progress |