← Back
One family attached or semi-detached
BARTOW STREET
STATEN ISLAND · BIN 5174853
💬 Discuss this project
2022Year Built
2Stories
A5Building Class
R3-1Zoning
1,513 sfGross Floor Area
1Units
One family attached or semi-detached · 2,525 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
Architecture
Floor 28p · 1 filing · 20 docs
Floor 18p · 1 filing · 20 docs
Basement9p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NIRO1307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TONY SAYAD ARCHITECT405/10/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NIRO INCGeneral Contractor407/08/2026
FLOW-RIGHT PLBG & HTG CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SRA PLANNING & EXPEDITING5677107/15/2021
Building Lifecycle
All (45)Filed (4)Permit Issued (3)Signed Off (2)Inspection (7)Objection (2)Special Inspection (27)
10/24/2023
Signed off — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-S1
10/24/2023
Signed off — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-S2
05/12/2022
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
05/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/10/2022
Filed — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-P1
05/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/29/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/21/2022
Permit issued — Curb Cut
S00521624-S1-CC
03/21/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
12/16/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/15/2021
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
09/21/2021
Permit issued — Plumbing
S00521624-S2-PL
08/31/2021
Permit issued — General Construction
S00521624-I1-GC-CX
08/23/2021
Objection raised — Scope
08/23/2021
Objection resolved — Addressed
07/19/2021
Filed — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-S2
07/17/2021
Filed — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-S1
07/15/2021
Filed — New Building
Plumbing worktype in conjunction with new 1-family residence filed under this application, to include storm drainage, gas work and water/sanitary
S00521624-I1
05/13/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Mechanical Systems
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Wood – Prefabricated I-Joists
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Concrete - Cast-In-Place
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Subgrade Inspections
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Final
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Footing and Foundation
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Structural Wood Frame
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Fenestration areas
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Electric vehicle service equipment requirements
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Fenestration air leakage
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — HVAC-R and service water heating equipment
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Air barrier — testing
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — HVAC-R and service water heating system controls
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Insulation placement and R values
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Air barrier - visual inspection
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Duct leakage testing, insulation and design
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Interior lighting power
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Maintenance information
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Permanent certificate
WILLIAM MONTAGUE
05/13/2021
Special inspection requirement — Ventilation and air distribution system
WILLIAM MONTAGUE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offNIRO INC04/21/2022
DOB NOWPlumbingSigned-offFLOW-RIGHT PLBG & HTG COR09/21/2021
DOB NOWGeneral ConstructionPermit IssuedNIRO INC08/31/2021
1 project · most recent 05/10/2022
Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/10/2022Signed-offNIRO INCAir Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Heat Controller RSG1336S1M-1 36,000 BTU · Condensing Unit ×1
Heating
Heat Controller GUH92C070B3M-1 40,000 BTU · Furnace ×1
Ventilation
Fantech FLEX 100H 110 CFM · Erv ×1
Ducts & Piping
Southwark Metal G-60 COATED GALVANIZED STEEL 24 GA. Ductwork ×1
1 project · most recent 05/10/2022
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/10/2022Signed-offFLOW-RIGHT PLBG & HTG CORGas, Storm, Water/Sanitary
1 project · most recent 12/10/2021
General Wiring
FiledStatusContractorScope
12/10/2021CompleteD AND H ELECTRICAL CONSTGeneral Wiring
1 project · most recent 05/10/2022
Wood
FiledStatusContractorScope
05/10/2022Signed-offNIRO INCWood
1 project · most recent 05/10/2022
Earthwork
FiledStatusContractorScope
05/10/2022Signed-offNIRO INCEarthwork
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
05/12/2022Pass-Final Curb Cut Non-Directive 14PassView ↗
05/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/29/2022Pass-Final CND-Occupancy InspectionPassView ↗
03/21/2022Pass-Final PL - UndergroundPassView ↗
12/16/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/15/2021Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
05/13/2021Subsurface Investigations (Borings/Test Pits)WILLIAM MONTAGUEspecial
05/13/2021Mechanical SystemsWILLIAM MONTAGUEspecial
05/13/2021Wood – Prefabricated I-JoistsWILLIAM MONTAGUEspecial
05/13/2021Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
05/13/2021Exterior Insulation and Finish Systems (EIFS)WILLIAM MONTAGUEspecial
05/13/2021Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
05/13/2021Subgrade InspectionsWILLIAM MONTAGUEspecial
05/13/2021FinalWILLIAM MONTAGUEprogress
05/13/2021Footing and FoundationWILLIAM MONTAGUEprogress
05/13/2021Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
05/13/2021Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
05/13/2021Structural Wood FrameWILLIAM MONTAGUEprogress
05/13/2021Fenestration areasWILLIAM MONTAGUEenergy_progress
05/13/2021Electric vehicle service equipment requirementsWILLIAM MONTAGUEenergy_progress
05/13/2021HVAC-R and service water piping design and insulationWILLIAM MONTAGUEenergy_progress
05/13/2021Fenestration air leakageWILLIAM MONTAGUEenergy_progress
05/13/2021HVAC-R and service water heating equipmentWILLIAM MONTAGUEenergy_progress
05/13/2021Air barrier — testing WILLIAM MONTAGUEenergy_progress
05/13/2021HVAC-R and service water heating system controlsWILLIAM MONTAGUEenergy_progress
05/13/2021Insulation placement and R valuesWILLIAM MONTAGUEenergy_progress
05/13/2021Fenestration and door U-factor and product ratingsWILLIAM MONTAGUEenergy_progress
05/13/2021Air barrier - visual inspectionWILLIAM MONTAGUEenergy_progress
05/13/2021Duct leakage testing, insulation and designWILLIAM MONTAGUEenergy_progress
05/13/2021Interior lighting powerWILLIAM MONTAGUEenergy_progress
05/13/2021Maintenance informationWILLIAM MONTAGUEenergy_progress
Latest 25 of 27.
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/24/2026S00521624-S1Request digital key ↗
08/24/2026S00521624-S2Request digital key ↗
08/24/2026S00521624-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00521624-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00521624-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026S00521624-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026S00521624-P1Open ↗
08/24/2026S00521624-I1Open ↗
08/24/2026S00521624-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/24/2026S00521624-I1Open ↗
08/24/2026S00521624-I1Open ↗
08/24/2026S00521624-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026S00521624-I1Open ↗
08/24/2026S00521624-I1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026S00521624-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026S00521624-I1—
▸Safety & Tenant Protection4
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00521624-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00521624-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026S00521624-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00521624-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026S00521624-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00521624-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026S00521624-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00521624-I1Open ↗
▸Other Documents3
▸DOB NOWFinal Survey1
08/13/2026S00521624-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00521624-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026S00521624-I1Open ↗