← Back
Two family frame
BEACH 68TH STREET
QUEENS · BIN 4623727
💬 Discuss this project
2022Year Built
2Stories
B2Building Class
R4-1Zoning
2,416 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family frame · 3,000 sf lot · 0.81 FAR built · Flood zone AE
Locations of Work
ArchitectureStructural
Roof1p · 1 filing · 12 docs
Floor 311p · 1 filing · 20 docs
Floor 212p · 1 filing · 20 docs
Floor 112p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNITED DEVELOPERS1504/09/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/10/2023$993K—BEACH 68 GROUP LLC → Private party$411/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC212/16/2024
PIROOZ ENGINEERING, P.C.502/13/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DESIGNS INCGeneral Contractor304/09/2026
NYS ESSENTIAL POWER INCGeneral Contractor107/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854212/16/2024
HRF SERVICES CORP5616202/13/2023
VICTOR SUBEN6672202/13/2023
IP CONCRETE TESTING AND I6252107/05/2022
PIROOZ ENGINEERING P.C7177107/05/2022
Building Lifecycle
All (58)Filed (7)Permit Issued (5)Signed Off (4)Violation (2)Inspection (10)Special Inspection (30)
06/05/2026
Violation issued (HPD, open)
B
06/05/2026
Violation issued (HPD, open)
B
12/19/2024
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01097096-I1
12/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
12/18/2024
Special inspection requirement — Final
TOM PETERSEN
12/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
12/18/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
12/18/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
12/16/2024
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01097096-P1
08/20/2024
Permit issued — Solar
Q01097096-I1-SL
08/15/2024
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01097096-I1
03/15/2023
Signed off — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION # Q00583565
Q00571023-I1
03/13/2023
Signed off — Alteration
Q00571024-I1
03/13/2023
Signed off — Alteration
Q00571022-I1
03/09/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
02/27/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/21/2023
Special inspection requirement — Masonry
Victor Suben
02/21/2023
Special inspection requirement — Mechanical Systems
Victor Suben
02/21/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Victor Suben
02/21/2023
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
FAHAD FATEH
02/21/2023
Special inspection requirement — Lowest Floor Elevation
Victor Suben
02/21/2023
Special inspection requirement — Air barrier — testing
Victor Suben
02/21/2023
Special inspection requirement — Structural Cold-Formed Steel
Victor Suben
02/21/2023
Special inspection requirement — Electric vehicle service equipment requirements
Victor Suben
02/21/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
INDARDEO PARBHUNATH
02/21/2023
Special inspection requirement — Heating Systems
Victor Suben
02/21/2023
Special inspection requirement — Final
NAVEEN KUMAR
02/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Victor Suben
02/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
Victor Suben
02/21/2023
Special inspection requirement — Footing and Foundation
Victor Suben
02/21/2023
Special inspection requirement — Preliminary
Victor Suben
02/21/2023
Special inspection requirement — Structural Wood Frame
Victor Suben
02/21/2023
Special inspection requirement — Ventilation and air distribution system
Victor Suben
02/21/2023
Special inspection requirement — Subgrade Inspections
Victor Suben
02/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Victor Suben
02/21/2023
Special inspection requirement — Insulation placement and R values
Victor Suben
02/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
Victor Suben
02/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Victor Suben
02/21/2023
Special inspection requirement — Interior lighting power
Victor Suben
02/21/2023
Special inspection requirement — Maintenance information
Victor Suben
02/21/2023
Special inspection requirement — Concrete - Cast-In-Place
Victor Suben
02/16/2023
Permit issued — Curb Cut
Q00571024-I1-CC
02/13/2023
Filed — New Building
PROPOSED 3 STORY, 2 FAMILY DWELLING FRAME BUILDING.
Q00583565-P1
02/10/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/08/2023
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
01/18/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/04/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/04/2022
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
11/04/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/04/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/04/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/11/2022
Permit issued — Plumbing
Q00571023-I1-PL
07/06/2022
Permit issued — Construction Fence
Q00571022-I1-FN
07/05/2022
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION # Q00583565
Q00571023-I1
07/05/2022
Permit issued — General Construction
Q00583565-I1-GC-CX
07/03/2022
Filed — Alteration
Q00571024-I1
06/23/2022
Filed — Alteration
Q00571022-I1
10/28/2021
Filed — New Building
PROPOSED 3 STORY, 2 FAMILY DWELLING FRAME BUILDING.
Q00583565-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYS ESSENTIAL POWER INC08/20/2024
DOB NOWCurb CutSigned-offJ&J DESIGNS INC02/16/2023
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR08/11/2022
DOB NOWConstruction FenceSigned-offJ&J DESIGNS INC07/06/2022
DOB NOWGeneral ConstructionPermit IssuedJ&J DESIGNS INC07/05/2022
1 job · most recent 02/13/2023
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/13/2023Permit IssuedJ&J DESIGNS INCHeating Systems, Ventilation Systems
Heating
Navien NCB-150E 100,000 BTU · Boiler ×2
Ventilation
Panasonic FV-05VQ5 50 CFM · Exhaust Fan ×4
FV-150VQ5 150 CFM · Exhaust Fan ×2
2 jobs · most recent 08/08/2024
General Wiring Boiler Controls
FiledStatusContractorScope
08/08/2024CompleteAMBER ELECTL CONTNG INC—
02/07/2023CompleteSKY ELECTRIC LLCGeneral Wiring, Boiler Controls
1 job · most recent 02/13/2023
Wood
FiledStatusContractorScope
02/13/2023Permit IssuedJ&J DESIGNS INCWood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
03/09/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
02/27/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/08/2023Fail-Final CND-Occupancy InspectionFailView ↗
01/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/04/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/04/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/04/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/04/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/04/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 69
DateRequirementInspectorRole
12/18/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
12/18/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
12/18/2024FinalTOM PETERSENprogress
12/18/2024Energy Code Compliance InspectionsTOM PETERSENprogress
12/18/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
02/21/2023Concrete - Cast-In-PlaceVictor Subenspecial
02/21/2023Excavations - Sheeting, Shoring, and BracingVictor Subenspecial
02/21/2023Fire-Resistant Penetrations and JointsVictor Subenspecial
02/21/2023Subgrade InspectionsVictor Subenspecial
02/21/2023Heating SystemsVictor Subenspecial
02/21/2023Subsurface Conditions – Fill Placement & In-Place DensityFAHAD FATEHspecial
02/21/2023Mechanical SystemsVictor Subenspecial
02/21/2023Structural Cold-Formed SteelVictor Subenspecial
02/21/2023MasonryVictor Subenspecial
02/21/2023Subsurface Investigations (Borings/Test Pits)INDARDEO PARBHUNATHspecial
02/21/2023Footing and FoundationVictor Subenprogress
02/21/2023Fire-Resistance Rated ConstructionVictor Subenprogress
02/21/2023Energy Code Compliance InspectionsVictor Subenprogress
02/21/2023FinalNAVEEN KUMARprogress
02/21/2023Lowest Floor ElevationVictor Subenprogress
02/21/2023PreliminaryVictor Subenprogress
02/21/2023Structural Wood FrameVictor Subenprogress
02/21/2023Ventilation and air distribution systemVictor Subenenergy_progress
02/21/2023Air barrier — testing Victor Subenenergy_progress
02/21/2023HVAC-R and service water piping design and insulationVictor Subenenergy_progress
Latest 25 of 69.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00571022-I1Request digital key ↗
08/26/2026Q00571024-I1Request digital key ↗
08/26/2026Q00571023-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00583565-I1Open ↗
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature11
09/04/2026Q00583565-I1Open ↗
09/04/2026Q00583565-I1Open ↗
09/04/2026Q00583565-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/04/2026Q00583565-I1Open ↗
09/04/2026Q00583565-I1Open ↗
09/04/2026Q00583565-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026Q00571024-I1Open ↗
08/26/2026Q00571023-I1Open ↗
08/25/2026Q00583565-I1Open ↗
Showing 3 of 7 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00583565-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00583565-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00583565-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01097096-P1Open ↗
08/21/2026Q01097096-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00583565-I1Open ↗
08/13/2026Q00571023-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00583565-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00583565-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01097096-I1Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/25/2026Q00583565-I1Open ↗
08/13/2026Q00583565-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00583565-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00583565-I1Open ↗
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)1
08/13/2026Q00583565-I1Open ↗